Manual.ly Logo

Testo 104-IR Manual

0.0 · 0 Ratings

PDF manual · 60 Pages

English

M: OA-GPT-54-NAN
page

/ 60

Loading...
eb55c828eb092ad57d3f284868bba5e43757 page b
1. General information 11
1. General information
Please read this document through carefully and familiarize
yourself with the operation of the product before putting it to use.
Keep this document to hand so that you can refer to it when
necessary.
2. Safety information
Avoid electrical hazards:
Do not conduct measurements on or near live parts!
Adhere to the product safety/warranty requirements:
Always operate the instrument properly and according to its
intended purpose and within the parameters specified. Do not
use force.
Do not store with solvents (e.g. acetone).
Only open the instrument if this is expressly described in the
documentation for the purpose of maintenance or repair work.
Ensure correct disposal:
Dispose of defective rechargeable batteries and spent
batteries at the collection points provided.
Send the instrument directly to us at the end of its life cycle.
We will ensure that it is disposed of in an environmentally
friendly manner.
3. Intended use
The testo 104-IR is a robust food thermometer.
The product is designed for the following tasks/areas:
· Food sector: production, food service, spot check
measurement, incoming goods.
· Measuring liquids, pastes and semi-solid materials
The following product components are designed for continuous
contact with foodstuffs in accordance with Regulation (EC)
1935/2004:
The immersion/penetration probe from the tip up to 2 cm before the
probe handle or the plastic housing. If provided, information about
penetration depths in the instruction manual or the mark(s) on the
immersion/penetration probe should be observed.
The product should not be used in the following areas:
· Potentially explosive areas
· For diagnostic measurements in the medical sector
deenfresitptsvnl????

Chat with your Testo 104-IR manual using AI

Get instant AI answers from your Testo 104-IR manual

Ask anything about the Testo 104-IR. Answers come from this manual, with the pages they are based on.

104-IR Maintenance Schedule

Remind me when maintenance is due
Yearly
Check and calibrate instrument

According to EN 13485, the measuring instrument should be checked and calibrated regularly under the terms of EN 13486.

When needed
Replace batteries

Change batteries when the low battery indicator appears or if the instrument cannot be switched on.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend 104-IR?

Yes No

Frequently Asked Questions

A

It combines a quick infrared surface check with a fold-out penetration probe, so users can switch between fast screening and more reliable core temperature measurement when needed.

Is this answer helpful?

A

Yes. It is designed for food-sector tasks such as production, receiving, service, and spot checks. The probe materials are intended for continuous contact with food within the stated limits.

Is this answer helpful?

A

No. Infrared mode measures the surface only. For internal or core temperature, you should use the penetration probe, especially when checking critical food safety values.

Is this answer helpful?

A

AutoHold automatically ends the contact measurement once the reading is stable. This is useful when you want a hands-free result without pressing extra buttons.

Is this answer helpful?

A

Emissivity affects how accurately the infrared sensor reads a surface. The default value of 0.95 is suitable for many foods, plastics, and non-metal materials.

Is this answer helpful?

A

Use mild household cleaners and avoid harsh solvents. The housing and probe can be rinsed, and the lens should be cleaned carefully with a soft swab and water or medical alcohol.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Dual infrared and penetration measurement in one compact food thermometer.
  • Fast response and useful HOLD/MIN/MAX and AutoHold functions for workflow efficiency.
  • IP65 housing and sturdy materials support daily use in demanding environments.
  • Default emissivity setting is well suited for food and many non-metal surfaces.
VS

Disadvantages

  • Infrared mode measures only the surface, so core temperature still needs a probe.
  • Battery life is practical but limited, so replacements may be needed during long shifts.
  • Accuracy depends on proper distance, clean optics, and stable measuring conditions.
  • Regular calibration is recommended, adding maintenance to the routine.
M: OA-GPT-54-NAN

Product Specification

Measurement Range

-58F to +482F

Power Supply

Battery operated (2x AAA battery)

Protection Class

IP65

Weight

0.43 lb

M: OA-GPT-54-NAN

Product Description

Testo 104-IR Infrared Thermometer Manual: A Practical Dual-Mode Tool for Food Safety

The Testo 104-IR Infrared Thermometer Manual highlights a smart, rugged thermometer built for real-world food handling. Combining infrared surface measurement with a fold-out penetration probe, it gives users a fast way to check temperatures without sacrificing accuracy when a deeper reading is needed. That flexibility makes it especially useful in kitchens, production lines, receiving areas, and quality checks where time and reliability matter.

Built for Food-Industry Workflows

This model is designed for liquids, pastes, semi-solids, and packaged foods. The infrared mode is ideal for quick spot checks, while the probe mode supports core temperature measurement in food products. Its default emissivity setting of 0.95 suits many food and non-metal surfaces, helping reduce setup time and simplifying everyday use.

The device also includes a 2-point laser, which helps users aim at the correct measurement zone, and a HOLD/MIN/MAX function for reviewing results after a reading. AutoHold adds convenience in contact mode by automatically freezing stable values. For busy teams, these features can save time and make repeated checks more consistent.

Durable, Clear, and Easy to Maintain

Built with an IP65-rated housing and a mix of ABS, TPE, PC, zinc die-cast, and stainless steel, the thermometer is made to handle demanding environments. It runs on two AAA batteries and offers a typical battery life of around 10 hours. The compact shape and foldable probe make it easy to carry and store, while the display and simple keys keep daily operation straightforward.

Accuracy is strong across the supported range, with probe measurement from -50 to +250 °C and IR measurement from -30 to +250 °C. The manual also stresses proper cleaning, regular calibration, and safe handling—especially in food settings where hygiene and traceability are essential.

Notes

  • Infrared readings measure surfaces, not internal temperature.
  • For critical food checks, verify with the penetration probe.
  • Clean the lens carefully and keep it free from moisture or dirt.
  • Annual calibration is recommended for dependable long-term use.

Overall, the Testo 104-IR Infrared Thermometer Manual points to a versatile, field-ready instrument that balances speed, hygiene, and practical precision.

M: OA-GPT-54-NAN

© Copyright 2026 Manual.ly