cable.
5. OPERATION DURING CHARGING
NB: Before charging check that the capacity of the battery (Ah)
which is to be charged, is not inferior to that reported on the
data table of the battery charger (C min). Follow the instructions,
taking great care to respect the order given below.
5.1 BATTERY PREPARATION
When recharging a WET-type battery, proceed as follows:
- Remove the caps of the battery charger (if foreseen) so as to let the
gas produced go out. Check that the level of the electrolyte covers
the plates of the battery. If these were not covered add distilled
water and cover them up to 5-10 mm.
WARNING: USE THE MAXIMUM CAUTION DURING
THIS OPERATION AS THE ELECTROLYTE IS A HIGHLY
CORROSIVE ACID.
5.2 BATTERY CHARGER/BATTERY CONNECTION
- Make sure the power cable is disconnected from the mains.
- With models having more than one charge voltage, turn the
deviator or the switch to the selected charge voltage. If there is
no deviator or switch, suitably connect the red crocodile clip (+
symbol) to the specic battery charger terminal in correspondence
with the selected charge voltage.
- Connect the red charge clamp to the positive terminal of the battery
( + symbol). If the symbols are indistinguishable remember that the
positive terminal is the one not connected to the vehicle chassis.
- Connect the black charge clamp to the vehicle chassis, at a safe
distance from the battery and the fuel pipe.
NOTE: if the battery is not installed in the vehicle, connect the clamp
directly to the negative terminal of the battery (- symbol).
5.3 MANUAL CHARGE AND AUTOMATIC CHARGE MODES
5.3.1 MANUAL CHARGE (CHARGE) MODE
Mode recommended for free electrolyte lead batteries (WET).
- Follow the instructions provided in paragraphs 5.1 and 5.2 carefully.
- Turn the switch seen in gure B-1 to the CHARGE position and set
the desired charge level using the switch seen in gure B-2.
- Power the battery charger by inserting the power cable into the
mains and pressing the switch to ON (if available).
- Monitor the charge indicator as described in paragraph 3.1.
NOTE: When the WET battery is charged, you will also notice the
liquid start to “boil”. It is recommended to interrupt the charging as
soon as this happens to prevent damage to the battery.
5.3.2 AUTOMATIC CHARGE (TRONIC) MODE
The models that operate in TRONIC mode are recommended for
charging sealed batteries (GEL, AGM).
- Follow the instructions provided in paragraphs 5.1 and 5.2 carefully.
- Turn the switch seen in gure B-2 to TRONIC and set the desired
charge level using the switch seen in gure B-2.
- Power the battery charger by inserting the power cable into the
mains. The battery charger controls the voltage present at the
battery ends and automatically disconnects the current supply
when the battery is charged (green charge LED) and connects
it again automatically when the battery starts to run down. The
TRONIC function is ideal for keeping batteries (AGM and WET)
automatically charged over time with no risk of damage.
5.4 SIMULTANEOUS CHARGING OF MULTIPLE BATTERIES
WARNING: do not simultaneously charge batteries of different
capacities, discharges or types. When simultaneous charging is
required, it is possible to use “series” or “parallel” connections (FIG.
D).
For “parallel” connections the batteries must have the same rated
voltage (Volt), corresponding to that supplied by the battery charger
and the total of the Ah must fall within the charge range of the battery
charger.
For “series” connections the batteries must have the same capacity
(Ah), and the total of the rated voltage of all the batteries must
correspond to the output rated voltage supplied by the battery
charger.
5.5 CHARGE ENDING
- Disconnect the power to the battery charger moving the switch to
OFF (if available) and remove the power cable from the mains.
- Disconnect the black charge clamp from the vehicle chassis or
from the negative battery terminal (symbol -)
- Disconnect the red charging clamp from the positive battery
terminal (+ symbol).
- Return the battery charger to a dry place.
- Close the battery cells again, using the relative caps (if present).
6. VEHICLE STARTING OPERATION
WARNING: Before proceeding, read the vehicle manufacturers
instructions carefully!
- Make sure the power line is protected by fuses or automatic
circuit-breakers with sizes as indicated on the rating plate by the (
) symbol.
- To make the starting process easier, charge the battery for 10-15
minutes at maximum level before starting.
- In order to prevent overheating in the battery charger, ALWAYS
carry out the starting operation according to the work/pause (on-
off) cycles as indicated on the appliance (e.g. START 3s ON 120s
OFF-5 CYCLES). Do not insist if the engine does not start: this
could cause serious damage to the battery or even to the electrical
equipment in the vehicle. If the engine does not start, do not insist,
but wait a few minutes and then repeat the rapid charge operation.
6.1 BATTERY CHARGER/BATTERY CONNECTION
- With the power cord disconnected from the mains, connect the
battery charger clamps as described in paragraph 5.2.
- Make sure the battery is connected properly to the respective (+
and -) terminals, and that it is in good condition (not sulphated or
dead). Never ever start vehicles with the batteries disconnected
from their respective terminals; the presence of the battery is
essential for the elimination of possible overvoltage.
6.2 STARTING WITH START
- With the battery charger switched OFF, plug the power cable into
the mains.
- Press the switch to ON, if available.
- Turn the switch to START and turn the vehicle ignition key to start
the engine.
6.3 END OF STARTING
- Disconnect the power to the battery charger by turning the switch
(if present) to OFF and remove the power cable from the mains.
- Disconnect the black crocodile clip from the negative battery
terminal (- symbol) and the red crocodile clip from the positive
battery terminal (+ symbol).
- Store the battery charger in a dry place.
7. BATTERY CHARGER PROTECTION
The battery charger protects itself from:
- Overcharge (too much current supplied to the battery).
- Short-circuit (loading clips placed in contact with each other).
- Polarity inversion on the battery clamps.
For appliances tted with fuses, if the fuses have to be replaced
always use the same kind of fuse with the same rated size.
WARNING: If the replacement fuse has a different size from that
shown on the rating plate it could cause damage to people or
property. For the same reason, never ever replace the fuse with a
bridge in copper or other material.
The power supply cable should always be DISCONNECTED from the
mains supply while the fuse is being changed.
8. USEFUL ADVICE
- If the positive and negative terminals are incrusted with oxide,
clean them to ensure good contacts with the clamps.
- Never ever allow the two clamps to come into contact when the
battery charger is connected to the mains. In this case the fuse will
blow.
- If the battery, to which this battery charger is to be connected,
is permanently installed in the vehicle, also consult the vehicle
manufacturer’s user’s and maintenance handbook under the
“ELECTRICAL SYSTEM” or “MAINTENANCE” section.

Chat with your Telwin Alaska 150 Start manual using AI

Get instant AI answers from your Telwin Alaska 150 Start manual

Ask anything about the Telwin Alaska 150 Start. Answers come from this manual, with the pages they are based on.

Alaska 150 Start Maintenance Schedule

Before each charge
Check electrolyte level and add distilled water if needed

For WET batteries, ensure electrolyte covers plates. If not, add distilled water to cover by 5-10 mm. Use extreme caution as electrolyte is corrosive.

As needed
Clean battery terminals of oxide

If positive and negative terminals are incrusted with oxide, clean them to ensure good contact with the clamps.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Alaska 150 Start?

Yes No

Frequently Asked Questions

A

Yes, the device is suitable for motorcycles, cars, and boats, supporting 12V and 24V systems depending on the model configuration.

Is this answer helpful?

A

TRONIC is automatic for sealed batteries like GEL and AGM, while CHARGE is manual for wet lead-acid batteries requiring user monitoring.

Is this answer helpful?

A

In TRONIC mode, the LED turns green. In CHARGE mode, watch the ammeter drop near zero or check for liquid boiling in wet batteries.

Is this answer helpful?

A

Yes, provided they have compatible voltages and capacities, connected either in series or parallel according to specific guidelines.

Is this answer helpful?

A

Yes, using the START function, but you must follow the recommended work-pause cycles to prevent overheating the charger.

Is this answer helpful?

A

Disconnect immediately. The device has protection, but sparks may occur. Reconnect correctly to avoid damage.

Is this answer helpful?

A

Store it in a dry place away from moisture and direct sunlight to ensure longevity and safety.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Supports both automatic TRONIC mode for sealed batteries and manual CHARGE mode for wet batteries
  • Includes a dedicated START function for high-current engine assistance
  • Features comprehensive protection against reverse polarity, short circuits, and overcharge
  • Compatible with 6V, 12V, and 24V battery systems for diverse vehicle types
  • Clear indicator LEDs and an ammeter provide real-time status feedback during operation
VS

Disadvantages

  • Requires strict adherence to ventilation rules due to explosive gas risks during charging
  • Cannot be used inside a vehicle or under the bonnet due to spark hazards
  • Multiple battery charging requires careful configuration of series or parallel setups
  • Fuse replacement must strictly match rated values to avoid equipment damage
  • Initial setup requires reading the manual carefully to understand voltage selection switches
M: QW-35-FL

Product Specification

Suitable for

AGM, Lead, Gel

Battery voltage

12V

Max charging current

12A

Battery capacity

10-200Ah

Display

Analog pointer

Features

Jump start

Color

black, white

Dimensions

9.65x7.68x5.12 in (WxDxH)

Weight

13.01 lbs

M: QW-35-FL

Product Description

Telwin Alaska 150 Start Manual: Your Ultimate Guide to Reliable Power

The Telwin Alaska 150 Start Manual serves as the essential companion for owners of this versatile battery charger and starter. This device is designed to handle a wide range of vehicles, including cars, motorcycles, and boats, ensuring that your power source remains robust and ready for action. Whether you are dealing with sealed GEL or AGM batteries using the advanced TRONIC mode, or traditional wet lead-acid batteries requiring manual CHARGE settings, this unit adapts to your needs with precision.

Understanding the operation of the Telwin Alaska 150 Start is crucial for safety and efficiency. The manual guides users through the critical steps of connecting clamps, selecting the correct voltage for 6V, 12V, or 24V systems, and monitoring the charge level via the integrated ammeter. It highlights the importance of working in well-ventilated areas to avoid explosive gases and emphasizes strict adherence to polarity rules to prevent sparks or damage to vehicle electronics. The START function offers a powerful boost for difficult engine starts, but it requires careful attention to work-pause cycles to prevent overheating.

Beyond basic charging, the guide explains how to safely charge multiple batteries simultaneously using series or parallel connections. It also details the protective features built into the charger, such as safeguards against overcharging, short circuits, and reversed polarity. By following these instructions, users can extend the life of their batteries and ensure the longevity of the charger itself. Proper maintenance, including cleaning terminals and storing the unit in a dry place, is emphasized throughout the text to maintain optimal performance.

Important Safety Notes

Always disconnect the mains cable before connecting or disconnecting clamps. Never operate the device in rain or snow. Ensure the fuse rating matches the plate specifications exactly. Do not attempt to repair internal components yourself; only qualified technicians should handle internal repairs.

Pros and Cons

Pros

  1. Supports both automatic TRONIC mode for sealed batteries and manual CHARGE mode for wet batteries.
  2. Includes a dedicated START function for high-current engine assistance.
  3. Features comprehensive protection against reverse polarity, short circuits, and overcharge.
  4. Compatible with 6V, 12V, and 24V battery systems for diverse vehicle types.
  5. Clear indicator LEDs and an ammeter provide real-time status feedback during operation.

Cons

  1. Requires strict adherence to ventilation rules due to explosive gas risks during charging.
  2. Cannot be used inside a vehicle or under the bonnet due to spark hazards.
  3. Multiple battery charging requires careful configuration of series or parallel setups.
  4. Fuse replacement must strictly match rated values to avoid equipment damage.
  5. Initial setup requires reading the manual carefully to understand voltage selection switches.

Frequently Asked Questions

Can I use the Telwin Alaska 150 Start on a motorcycle? Yes, the device is suitable for motorcycles, cars, and boats, supporting 12V and 24V systems depending on the model configuration.

What is the difference between TRONIC and CHARGE modes? TRONIC is automatic for sealed batteries like GEL and AGM, while CHARGE is manual for wet lead-acid batteries requiring user monitoring.

How do I know when the battery is fully charged? In TRONIC mode, the LED turns green. In CHARGE mode, watch the ammeter drop near zero or check for liquid boiling in wet batteries.

Can I charge two batteries at the same time? Yes, provided they have compatible voltages and capacities, connected either in series or parallel according to specific guidelines.

Is it safe to start a car with this device? Yes, using the START function, but you must follow the recommended work-pause cycles to prevent overheating the charger.

What should I do if the polarity is reversed? Disconnect immediately. The device has protection, but sparks may occur. Reconnect correctly to avoid damage.

Where should I store the charger after use? Store it in a dry place away from moisture and direct sunlight to ensure longevity and safety.