Manual.ly Logo

Sygonix SY-4966400 Manual

0.0 · 0 Ratings

PDF manual · 12 Pages

English

M: OA-GPT-5-NAN
page

/ 12

Loading...
5286f7a5a3f4ec1a70719e16b2715c2cb987 page 4
4
Operating Instructions
Battery Operated Smoke Detector
Item no: 2483200
1 Intended use
The product is a photoelectric smoke alarm. If smoke in the room reaches a certain concentration, the
alarm will activate and trigger sound and light warnings.
The product is intended for private use only.
Not approved for installation into leisure accommodation vehicles (e.g., caravans).
The product is intended for indoor use only. Do not use it outdoors.
Contact with moisture must be avoided under all circumstances.
If you use the product for purposes other than those described, the product may be damaged.
Improper use can result in short circuits, fires, or other hazards.
The product complies with the statutory national and European requirements.
For safety and approval purposes, you must not rebuild and/or modify the product.
Read the operating instructions carefully and store them in a safe place. Make this product available to
third parties only together with the operating instructions.
All company names and product names are trademarks of their respective owners. All rights reserved.
2 Delivery contents
■
Product
■
1x CR123A (pre-installed in product)
■
Double-sided adhesive tape
■
2x screws
■
2x dowels
■
Operating instructions
3 Latest product information
Download the latest product information at www.conrad.com/downloads or scan the QR code shown. Fol-
low the instructions on the website.
4 Symbols in this document
The symbol warns of hazards that can lead to personal injury. Read the information carefully.
The symbol warns of dangerous voltage that can lead to personal injury by electric shock.
Read the information carefully.
5 Safety instructions
Read the operating instructions carefully and especially observe the safety informa-
tion. If you do not follow the safety instructions and information on proper handling,
we assume no liability for any resulting personal injury or damage to property. Such
cases will invalidate the warranty/guarantee.
5.1 General
■
The product is not a toy. Keep it out of the reach of children and pets.
■
Do not leave packaging material lying around carelessly. This may become dangerous playing mater-
ial for children.
■
If you have questions which remain unanswered by this information product, contact our technical
support service or other technical personnel.
■
Maintenance, modifications and repairs must only be completed by a technician or an authorised re-
pair centre.
5.2 Handling
■
Handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.
5.3 Operating environment
■
Do not place the product under any mechanical stress.
■
Protect the appliance from extreme temperatures, strong jolts, flammable gases, steam and solvents.
■
Protect the product from high humidity and moisture.
■
Protect the product from direct sunlight.
5.4 Operation
■
If it is no longer possible to operate the product safely, take it out of operation and protect it from any
accidental use. DO NOT attempt to repair the product yourself. Safe operation can no longer be guar-
anteed if the product:
– is visibly damaged,
– is no longer working properly,
– has been stored for extended periods in poor ambient conditions or
– has been subjected to any serious transport-related stresses.
5.5 Battery safety information
■
Never place rechargeable batteries in the smoke detector.
■
Use only non-rechargeable batteries to ensure a safe and the longest possible operation.
■
Keep batteries out of the reach of children.
■
Do not leave batteries lying around, as they constitute a choking hazard for children and pets. Seek
immediate medical attention if a battery is swallowed.
■
When handling leaking or damaged batteries, always use suitable protective gloves to avoid burning
your skin.
■
Batteries must never be short-circuited, disassembled, or thrown into the fire. This may cause an ex-
plosion!
■
Never attempt to recharge non-rechargeable batteries, as this may cause an explosion.
■
Ensure that the batteries are inserted in the correct polarity (observe the plus/+ and minus/- signs).
5.6 Limitations of smoke alarms
■
Smoke alarms have sensing limitations, and it is important to consider some points for maximum pro-
tection. For example:
– Ionization sensing alarms may detect invisible fire particles (e.g., fast flaming fires) sooner than
photoelectric alarms.
– Photoelectric sensing alarms may detect visible fire particles (e.g., slow, smouldering fires) sooner
than ionization alarms.
■
Consult an expert when in doubt about the operation, safety or connection of the product.
6 Product overview
1 2 3
4
1 Test button / LED indicator
2 Speaker
3 Smoke detection holes
4 Battery compartment
7 Battery
Important:
■
Removal of the smoke alarm battery will render the smoke alarm inoperative.
■
Insert the battery before attaching the mounting plate.
■
For safety reasons, the mounting plate cannot be attached to the product if no battery has been
inserted.
■
For safety reasons, do not use rechargeable batteries; use only non-rechargeable batteries.
7.1 Insert battery
1. For first time use, remove the plastic battery insulation strip.
2. When inserting a battery, be sure to match the polarity shown inside
the compartment.
7.2 Low battery warning
Replace the battery when the following warning(s) show:
■
Mobile application: shows low battery.
■
Product: 1x red flash / 1x beep every 40 seconds.
8 Installation
Important:
■
Insert the battery before attaching the mounting plate to the product. The mounting plate cannot
be attached to the product if no battery has been inserted.
■
Before mounting, check which direction the bracket needs to be facing for it to attach to the
product.
8.1 Location
The smoke alarm should:
■
be installed on the ceiling in the middle of the room.
■
only be installed indoors and at least one alarm in each room.
■
be at least 150 cm away from lights, exhaust fans, air conditioners and air inlet/outlets.
■
not be installed in a bathroom or places where condensation occurs.
8.2 Wall mount
Risk of fatal electric shock or damage! Before drilling, check for concealed wires or pipes be-
neath the surface that could be damaged or cause harm.

Chat with your Sygonix SY-4966400 manual using AI

Get instant AI answers from your Sygonix SY-4966400 manual

Ask anything about the Sygonix SY-4966400. Answers come from this manual, with the pages they are based on.

SY-4966400 Maintenance Schedule

Remind me when maintenance is due
Weekly
Test the alarm function

Press the test button to ensure correct operation. Stand an arms-length away due to loud volume.

Every 2 years
Replace the battery

Replace the CR123A battery after approximately 2 years or when low battery warnings appear.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend SY-4966400?

Yes No

Frequently Asked Questions

A

The unit uses one 3 V CR123A lithium battery (preinstalled). Typical battery life is approximately two years under normal conditions; replace immediately when low-battery warnings appear (1x red flash + 1x beep every 40 seconds).

Is this answer helpful?

A

The detector requires a 2.4 GHz Wi‑Fi network (IEEE 802.11 b/g/n). It is not compatible with 5 GHz networks. Ensure your mobile device and the detector connect to the same 2.4 GHz SSID (case sensitive) when pairing using AP or EZ mode.

Is this answer helpful?

A

Test the alarm weekly by pressing the Test button (stand an arm’s length away). Clean the outer casing and detection holes periodically with a dry, lint-free cloth or a vacuum with a soft brush attachment; avoid solvents, alcohol or immersing the unit in water.

Is this answer helpful?

A

Status codes include: 1x red flash every 40 seconds = normal standby; continuous red flash + continuous beep = smoke alarm; 1x red flash + 1x beep every 40 seconds = low battery; 2x red flash + 2x beep every 40 seconds = device fault; 3x red flash + 3x chirp every 40 seconds = Wi‑Fi network error.

Is this answer helpful?

A

Yes. Press and hold the Test button to hush a nuisance alarm for 9 minutes. If smoke concentration remains above the alarm threshold after 9 minutes, the alarm will reactivate automatically.

Is this answer helpful?

A

Mount the detector on the ceiling near the center of the room, at least 150 cm from lights, exhaust fans and air inlets/outlets. Do not install in bathrooms, very humid areas, or outdoors. Use screws/dowels or the supplied adhesive on appropriate surfaces.

Is this answer helpful?

A

If the detector indicates a fault (2x red flash + 2x beep every 40 seconds), remove it from service and contact authorized customer support. Do not attempt to repair or modify the device yourself.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Photoelectric sensing ideal for detecting slow, smouldering fires and visible smoke particles.
  • Wi‑Fi connectivity (2.4 GHz) with Smart Life app gives remote push notifications and battery monitoring.
  • Compact, lightweight design with easy ceiling or adhesive mounting and preinstalled battery.
  • Loud alarm (≥85 dB at 3 m) plus visual LED indications and clear blink codes for status.
  • Low standby current (<9 µA) and approx. 2-year battery life with CR123A lithium cell.
VS

Disadvantages

  • Not compatible with 5 GHz Wi‑Fi networks — requires 2.4 GHz connection for app features.
  • Photoelectric sensors may detect slow fires better but can be slower on fast flaming fires than ionization units.
  • Mounting plate cannot be attached without a battery inserted, complicating pre-install preparation.
  • Not rated for outdoor use or installation in caravans; avoid humid areas such as bathrooms.
  • Uses single-use CR123A battery only; no rechargeable battery support, requiring periodic replacements.
M: OA-GPT-5-NAN

Product Specification

Type

Smoke detector

Sensors

Smoke particles

Alarm zones

1

Standard

Wi-Fi 4 (WLAN 802.11b/g/n)

Power supply

Battery (CR123A)

Operating temperature

32F to +131F

Dimensions

2.99x2.99x1.14in

Weight

0.19lb

Special features

Siren (85dBA), app-controlled

M: OA-GPT-54-NAN

Product Description

Sygonix SY-4966400 Wireless Smoke Detector

The Sygonix SY-4966400 Wireless Smoke Detector is a compact, battery-powered photoelectric alarm designed for reliable home protection. Lightweight and easy to install, it uses a single CR123A lithium battery (preinstalled) and offers audible, visual and app-based alerts to keep you informed of smoke events and battery status.

Key features and operation

This detector senses visible smoke particles using photoelectric technology, making it especially effective for detecting slow, smouldering fires. When smoke reaches a threshold, the alarm emits a continuous audible beeper (≥85 dB at 3 m), a steady red LED, and sends a push notification via the Smart Life - Smart Living mobile app. Normal operation is indicated by a single red blink every 40 seconds.

The unit supports Wi‑Fi (2.4 GHz, IEEE 802.11 b/g/n) for remote notifications and battery monitoring. Pairing methods include AP and EZ modes. LED blink patterns indicate Wi‑Fi connection status, network errors, low battery or device faults.

Installation and placement

Mount on the ceiling in room centers for optimal coverage. Keep detectors at least 150 cm from vents, lights and HVAC outlets and avoid bathrooms or damp areas. The detector can be surface-mounted with screws and dowels or attached with the supplied double-sided adhesive on clean, non-porous surfaces. Insert the battery before securing the mounting plate; the plate will not attach without a battery.

Testing, maintenance and safety

Weekly alarm tests are recommended—press the test button (stand an arm’s length away during tests). The hush function silences nuisance alarms for 9 minutes. Replace the CR123A battery roughly every two years or when low-battery warnings appear (1x red flash + beep every 40 seconds). Clean periodically with a dry, lint-free cloth or vacuum with a soft brush; do not use solvents or immerse the unit in water.

Standards and disposal

The detector complies with EN 14604 and EU radio directives; Conrad Electronic distributes it. At end of life, follow local WEEE regulations and remove and recycle batteries separately according to battery disposal laws.

Notes

  • Use only non-rechargeable CR123A batteries; rechargeable cells are prohibited.
  • Do not open, modify, or attempt repairs—contact authorized service for faults.
  • The product is for indoor domestic use only and not approved for caravans or outdoor use.
M: OA-GPT-5-NAN