NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO A POWER SOURCE
5
© 2020, Obelis S.A Registered Address:
Bd. Général Wahis, 53, 1030 Brussels, Belgium
Operation
This heater is factory-tested for use with 1-K kerosene/paraffin,
no. 1 & no. 2 diesel, JP8/Jet A Fuel, and no. 1 & no. 2 fuel oil.
TO START THE HEATER:
1. Fill the tank with paraffin until fuel gauge points to “F”.
2. Be sure fuel cap is secure.
3. Plug power cord into electrical outlet.
4. Turn thermostat control knob to desired temperature setting
(70/125/175/215 only). The setting range is from 5
°
C to 45
°
C. Push the Power switch to the “ON” position. The power
indicator lamp and room temperature display (125/175/215
only) will light and the heater will start.
Optimum pressure occurs when the nose cone is cherry red
and there are no extending flames from the heater.
NOTE: The room temperature display (125/175/215 only) will
indicate the following:
- When temperature is less than -17
°
C, display says “LO”.
- When temperature is above 37
°
C, display says “HI”.
- Between -17
°
and 37
°
C display shows actual temperature.
TO STOP THE HEATER: Turn the Temp. Setting Knob to left,
turn the Power Switch to “OFF” position, and unplug the Power
Cord.
TO RESTART THE HEATER
1. Wait ten seconds after shutting off heater.
2. Turn the Power Switch to “ON” position.
3. Be sure to follow all starting procedure precautions.
LONG TERM STORAGE
Drain Fuel Tank
1. For models ST-45/70T/70TW-KFA-E, drain fuel through the
fuel cap opening using an approved siphon. For models
ST-125/175/215-KFA-E, drain fuel through the Drain Plug at
the bottom of the Fuel Tank.
2. To remove the Drain Plug (125/175/215), pull the Plug Grip
downward and remove seal head from drain hole in tank.
3. Rinse and completely empty the tank.
4. To replace, push the drain head fully into the drain hole and
secure by pushing the seal cap fully into the head hole.
IMPORTANT: Never store leftover fuel over the summer.
Using old fuel can damage your heater.
Store heater in a dry, well-ventilated area! If your heater
cannot be stored indoors, a tarp or weatherproof cover must be
used to protect the heater.
Be sure that the storage area is free of dust and corrosive
vapors. Repack the heater in the original shipping material. Keep
the Users Manual in an easily accessible place.
Maintenance
Always service heater in a clean, flat, dry area. Never service
heater while it is plugged in or while hot!
Never service heater in wet conditions. In an emergency, be
sure heater has completely cooled before servicing using a
tarp or weatherproof cover, to ensure heater or electronics
inside heater are not exposed to wet conditions. Do not
service heater while plugged in under any circumstance.
FUEL/FUEL TANK: Flush every 200 hours of operation or as
needed with paraffin.
AIR FILTERS: Open heater lid to access filters. Filters should
be replaced every 500 hours of operation, or less, depending on
conditions. See figure 7.1 on page 7 for detailed view.
FAN BLADES: Open heater lid to access fan blades. Blades
should be cleaned at least once per heating season. See figure
6.1 on page 7 for detailed view.
NOZZLES: Open heater lid and remove burner head to access
nozzle. Nozzles should be cleaned or replaced at least once per
heating season. See figure 3.1 on page 7 for detailed view.
SPARK PLUG: Open heater lid to access spark plug. Clean and
re-gap every 600 hours of operation, or replace as needed.
Re-gap the terminals to 3.5mm. See figure 3.1 on page 7 for
detailed view.
PHOTOCELL: Open heater lid to access photocell. The Photocell
should be cleaned at least once per heating season or more
depending on conditions. See figures 4.1 and 5.1 on page 7 for
detailed view.
After servicing your heater you should perform the following
function check before commissioning this heater:
- check the air and fuel lines for leaks using a 50/50 soap
solution
- check extension cord for wear, cracks or cuts
- check to see igniter lines are connected securely to spark plug
Improper maintenance can lead to poor combustion and
soot production. Never alter or modify the heater. Use
only genuine parts from the manufacturer or sales agent
for repair and maintenance on your heater, and contact the
manufacturer or sales agent before replacing parts other
than those specified or recommended.
PUMP PRESSURE ADJUSTMENT:
While heater is operating, turn relief valve clockwise to increase,
counterclockwise to decrease. Use flat blade screwdriver to turn
valve. Correct pump pressure is on page 2.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety. Children should
be supervised to ensure that they do not play with the
appliance.
If the power cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Figure 2. Start The Heater
On / Off Switch
LED Operating
Time/ Temp
Temp Setting Knob
LED - Fuel Gauge

Chat with your Stanley ST-125T-KFA-E manual using AI

Get instant AI answers from your Stanley ST-125T-KFA-E manual

Ask anything about the Stanley ST-125T-KFA-E. Answers come from this manual, with the pages they are based on.

ST-125T-KFA-E Maintenance Schedule

Every 200 hours
Flush fuel tank

Flush the fuel tank with paraffin every 200 hours of operation or as needed to prevent issues.

Every 500 hours
Replace air filters

Open heater lid and replace air filters every 500 hours of operation or sooner depending on conditions.

Once per heating season
Clean fan blades

Open heater lid and clean fan blades at least once per heating season.

Once per heating season
Clean or replace nozzle

Open heater lid, remove burner head, and clean or replace the nozzle at least once per heating season.

Every 600 hours
Clean and re-gap spark plug

Open heater lid, clean the spark plug, and re-gap terminals to 3.5mm every 600 hours of operation.

Once per heating season
Clean photocell

Open heater lid and clean the photocell at least once per heating season or more depending on conditions.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend ST-125T-KFA-E?

Yes No

Frequently Asked Questions

A

The heater is designed to run on diesel or paraffin fuel. It is not suitable for gasoline, benzene, alcohol, or other volatile compounds which can cause fire or explosion.

Is this answer helpful?

A

Always place the appliance on a flat, stable, heat-resistant surface. Ensure proper ventilation is available and keep combustibles at the recommended safety distance.

Is this answer helpful?

A

Drain the fuel tank completely using the drain plug or siphon. Store the heater in a dry, well-ventilated area and protect it with a tarp if stored outdoors.

Is this answer helpful?

A

Clean fuel lines every 200 hours, replace air filters every 500 hours, and clean fan blades or nozzles at least once per heating season.

Is this answer helpful?

A

No, this unit produces carbon monoxide and is only for temporary heating in well-ventilated areas. It is not suitable for bedrooms or residential homes.

Is this answer helpful?

A

E1 typically indicates incorrect pump pressure, dirty filters, a dirty nozzle, or issues with the photocell or electrical connections.

Is this answer helpful?

A

Children aged 8 and above can use it only if supervised. Children under 8 should not operate it, and younger children must be kept away while it runs.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • Thermostat control allows precise temperature regulation between 5C and 45C
  • Digital display shows ambient temperature and fuel levels clearly
  • Sturdy wheel support frame ensures mobility across rough ground
  • Fuel flexibility supports diesel or paraffin usage
  • High thermal power suitable for large industrial spaces
VS

Disadvantages

  • Not suitable for primary heating in homes or recreational vehicles
  • Requires mandatory ventilation to prevent carbon monoxide poisoning
  • Old fuel deteriorates quickly and can damage internal components
  • Heavy unit requires stable flat surface for operation
  • Safety supervision needed when children are present
M: qwen/qwen3.5-flash-20260224

Product Specification

Rated Heat Output

36.6 kW

Color

black, gray

Heating Area

up to 3,100 sq ft

Heat Settings

Yes

Fuel

Diesel

Features

casters, carrying handle

Mounting Type

freestanding

Dimensions

39.0 x 26.0 x 24.0 in (W x H x D)

Weight

60.63 lbs

M: qwen/qwen3.5-flash-20260224

Product Description

Reliable Heating Solutions for Construction

Maintaining a comfortable working environment on a construction site or in a large industrial space requires efficient heating solutions. The Stanley ST-125T-KFA-E Diesel Air Heater stands out as a powerful option for temporary climate control. This unit delivers substantial thermal power capable of warming significant cubic meters of space effectively. When evaluating the best equipment for your specific project needs, referencing the Stanley ST-125T-KFA-E Diesel Air Heater Manual provides critical safety and operational guidance. Understanding these instructions ensures that the appliance runs safely and efficiently over extended periods.

Key Features and Operation

The device operates using diesel or paraffin fuel, which is widely available for industrial applications. The tank capacity supports extended operation times without constant refueling interruptions. A digital thermostat allows precise temperature regulation between five degrees and forty-five degrees Celsius. The display screen provides clear visibility of room temperature and fuel levels for the operator. This feature helps prevent cold spots and ensures workers remain productive in chilly conditions.

Safety and Portability

Portability is a key design element. The heater mounts on a sturdy wheel support frame, making it easy to move across rough ground. Always place the unit on a stable, flat surface to ensure proper combustion. Safety warnings are extensive due to the nature of direct-fire heaters. Proper ventilation is mandatory to prevent carbon monoxide poisoning. You must provide specific opening sizes for outside air intake based on the heater rating. Never block the front air outlet or rear air inlet during operation.

Maintenance and Long Term Care

Maintenance routines are straightforward but must be followed strictly. Clean the air filters every five hundred hours of operation to maintain performance. The spark plug requires inspection and cleaning every six hundred hours. Always drain the fuel tank completely before storing the heater for long periods. Old fuel deteriorates and can damage internal components. Never refill the tank while the unit is hot or running to avoid fire hazards.

Final Recommendations

This heater is designed for workshops and temporary structures rather than residential living spaces. It is not suitable for primary heating in homes or recreational vehicles. If any part of the power cord shows wear, it must be replaced immediately. Keep all combustible materials away from the front clearance areas as specified. This ensures that the equipment provides reliable heat while minimizing risk factors for your workforce. It requires attention to detail regarding fuel quality and electrical connections for best results.

Troubleshooting and Notes

If troubleshooting issues arise, the LED display may show error codes like E1. This often indicates pump pressure issues or dirty filters which need immediate attention. Checking the photocell and wiring connections resolves many common faults effectively. Regular checks on the nozzle and ignitor ensure consistent combustion quality. Proper care prevents soot production and maintains thermal efficiency over time.

M: qwen/qwen3.5-flash-20260224