Shelly EM measures true (active) power, reactive power (VAR), power factor and voltage. It supports two independent channels, each with current measurement up to 120A at 230V, and provides historical consumption graphs.
Is this answer helpful?
After safe installation and powering the device, it creates a WiFi Access Point (SSID like shellyem-XXXX). Connect your phone to that AP or open 192.168.33.1 in a browser to access the web UI, or use the Shelly Cloud app to add the device and join your home WiFi (Client mode).
Is this answer helpful?
No. The Shelly EM relay is rated to 2A/230V and is meant to control contactors or low-current devices. Use an appropriately rated contactor or relay for switching heavy loads.
Is this answer helpful?
Installation involves live mains and CT connections and should be performed by a qualified electrician. The manual warns against connecting CTs to live conductors and stresses powering off local circuits before wiring to avoid electrocution and device damage.
Is this answer helpful?
Yes. Shelly EM integrates with Shelly Cloud for remote access and supports Amazon Alexa and Google Assistant for voice control. It also offers local control via HTTP/UDP and developer protocols like MQTT or CoAP.
Is this answer helpful?
Firmware updates are available through the web interface or Shelly Cloud. You can restrict web UI access with a username and password, enable or disable cloud connectivity, and configure WiFi backup networks for resilience.
Is this answer helpful?
Always wire CTs per the manual, never clamp CTs on live conductors before connecting to Shelly EM, and ensure CT polarity (P+/P-) is correct. CTs produce high voltages when open-circuited; never leave secondary open while energized.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Two independent channels with per-channel measurements up to 120A, ideal for split-circuit monitoring.
- WiFi connectivity with embedded web server, Shelly Cloud support, and compatibility with Alexa/Google Assistant.
- Detailed telemetry: real power, reactive power, power factor, voltage and yearly history graphs.
- Supports developer protocols (MQTT, CoAP, HTTP/UDP) and firmware updates for integrations and future features.
- Compact DIN-friendly form factor with low device consumption (<1W) for seamless panel installation.
Disadvantages
- Relay limited to 2A — requires external contactor for high-current switching.
- Installation must be performed by a qualified electrician due to risk of electrocution.
- CT clamps must never be connected to live lines; improper wiring can damage device or create hazards.
- 2.4 GHz WiFi only; no 5 GHz support may limit network placement in congested environments.
- Indoor WiFi range can be limited (~30m), potentially requiring network planning or extenders.
Product Specification
Type
Sensor
Standard
WLAN (802.11b/g/n)
Function
Current measurement function
Topology
Bus/Star
Dimensions
1.54x1.42x0.67 in
Special features
App controllable (Android, iOS)
Note
Please note the type (50A/120A) and number of current clamps.
Product Description
Shelly EM WiFi Energy Meter 2-Channel Current Sensing Sensor Manual
The Shelly EM is a compact, two-channel WiFi energy meter designed for in-panel installation to monitor and control electrical consumption per channel. It measures up to 120A per channel, supports current transformers, and provides a 2A relay output for controlling contactors or loads. Powered from 110–230V AC, the device uses WiFi 802.11 b/g/n (2.4 GHz) to communicate with mobile apps, browsers or automation systems via HTTP/UDP, and can operate in Access Point or Client mode.
With a built-in web server and cloud integration through Shelly Cloud, the Shelly EM offers real-time readings—consumption (W), voltage (V), reactive power (VAR) and power factor—plus historical graphs spanning up to a year. The meter can show exported solar generation as negative consumption (green), and helps track true power (billing energy) and reactive power (non-billable). It supports advanced connectivity options including MQTT and CoAP for developer use.
Installation requires a qualified electrician: connect neutral and line inputs, attach current transformers (P1+/P1-, P2+/P2-), and mount the device in a breaker console. The unit creates its own AP on first power-up for setup or can join an existing WiFi network. Safety cautions stress powering down mains before wiring, avoiding connection of CT clamps to live lines, and respecting the maximum load ratings.
The Shelly EM’s mobile and embedded web interfaces allow naming devices, assigning rooms, viewing live metrics, and configuring schedules, timers, and automation scenes. Timers include Auto ON/OFF with second-level precision; Weekly Schedule supports sunrise/sunset-based actions when internet-connected. Security features include optional cloud access, login restriction with username/password, and backup WiFi configuration for failover.
Device settings cover power-on default state (ON, OFF, Restore Last), current transformer type, timezone/geo-location, SNTP server, firmware updates, and factory reset. The Details page displays per-channel consumption, power factor, voltage and a history graph; device info exposes IP, signal strength, and unique device ID. Shelly EM integrates with Amazon Alexa and Google Assistant for voice control when used through the cloud or local integrations.
Notes:
- Rated measurement: 120A per channel; relay max load 2A/230V.
- Radio range varies: up to ~50m outdoors and ~30m indoors, depending on construction.
- Electrical consumption of the device is <1W.
- Follow all safety warnings; incorrect installation may cause damage or injury.
Search for 67,706 Manuals online
Type-in Brand or Model
sowen32
8 months ago
My clamp sensors show different current values even when I use the same phase. Shouldn't the readings match if only one load is connected?
Manual.ly
8 months ago
The readings should match only if the clamps are measuring the exact same conductor carrying the same current. If the current clamps are not centered or fully closed around the conductor, or if one clamp is on a different wire (or includes multiple conductors), values can differ. Also make sure the clamp is firmly installed in the same orientation each time and that no other consumers are sharing the measured cable segment. For troubleshooting, verify you used the correct current sensors (they are often sold separately) and that you installed them on the power cable for the room and the specific outlet/device you want to compare. If everything is installed correctly, check the app for firmware updates and run any available calibration or sensor check.