Information for use
sera External Filters UVC-Xtreme 800 and UVC-Xtreme 1200
Please read these instructions carefully and keep for future use. When forwarding this unit to third parties, this information for use is also
to be handed over.
Congratulations!
Congratulations for buying the UVC-Xtreme external lter. The UVC-
Xtreme 800 and 1200 external lters provide UV-C supported lter per-
formance while saving energy to an extent that could not yet reached
before. The modern low noise low voltage motor can be adjusted to the
desired performance precisely and just as required via the control panel,
and thus extends the application range of these external lters. High
pump performance can already be selected in energy saving mode with
wattages between 5 W – 10 W. This is possible due to a hydrodynami-
cally optimized drive and ideal dimensioning.
The lters include an integrated UV-C unit that is switchable via the
control panel. This is operated with a specially doped and particularly
powerful amalgam lamp, and ensures even higher reduction of pathogens
and oating algae compared to common UV-C lamps. This indirectly
supports the health of the sh in a merely physical manner, while the
density of many algae stadiums is reduced at the same time.
An electric suction pump allows for comfortably drawing water into the
lter, which furthermore also provides a permanent de-aeration function.
The lter media baskets are optimized considering ow rate and volume,
and provide numerous applications with various lter media.
This combination makes the lters of the Xtreme series very service
friendly and allows for long service intervals. The valves are rotatable by
360°. They make placing the lter very exible and make it easy to place
and handle them. The lter includes a complete connection kit consist-
ing of intake and outlet tubes, hoses and attachment material. The 24 V
ballast powers the lter via an easily accessible plug connection at the
side of the lter head.
SAFETY PRECAUTIONS
1. WARNING: Dangerous ultraviolet radiation!
a. To prevent eye damage, never look directly into the UV-C lamp
without protection when it is operating (eye damage!) The UV-C
lamp provides a protective switch-off against looking into it
accidentally. The protective mechanisms must not be deacti -
vated.
b. Use only original sera amalgam replacement lamps for the UV-C
unit.
2. Make sure that voltage and frequency of the mains supply matches
the data on the type plate before connecting the ballast to the mains
supply. Position the ballast above the UVC-Xtreme external lter, and
use exclusively the ballast provided by sera.
3. The UVC-Xtreme external lter must be placed safely and dry below
the water surface level. Placing it more than 1.5 m (4.9 ft.) below the
water surface level is not permitted.
4. Usage is permitted only indoors.
5. Check plug and socket for water being present before putting into
operation. Never touch the plug or the socket before switching off
the circuit in case of a wet plug or a wet socket. Protect the power
plug against moisture and dripping water.
6. Never pull the power plug out of the socket by the cable.
7. Never operate without or without sufcient water ow.
8. Especially before working in the aquarium (water) or at the UVC-
Xtreme external lter, disconnect it and all other electrical appliances
from the mains supply.
9. The UVC-Xtreme external lter may only be operated completely
assembled.
10. Operation is permitted only for the described application pur pose.
11. The water temperature must not exceed 35°C (95°F).
12. Damage of the motor, the cable or the plug must not be repaired!
In this case the lter must immediately be disconnected from mains
supply, and must not be operated any more. This also applies in case
of intended alterations of these parts. This kind of damage must not
be repaired or mended. In case of damage or leakage at the lter
canister, at the seals, or in the parts that contain water, the lter must
immediately been taken apart and repaired.
13. The circuit to which the UVC-Xtreme external lter is connected must
be protected with a fault current protection switch (RCD 30 mA).
14. Always carry the lter by supporting the bottom. Never lift it by the
lter head, its external parts or its hose connections.
15. Operate the ballast only in a dry environment. Install ballasts pro-
tected against splash water.
16. Operate the lter only in upright position. Do not lay down or tilt.
17. Do not expose the appliance to damage by frost.
18. Product contains magnetic and electromagnetic components that
may affect or damage magnetic elds. People wearing cardiac pace-
makers should keep the required safety distance according to the
cardiac pacemaker manuals.
19. When doing maintenance at the rotor, be careful about the crushing
hazard due to magnetic forces.
20. The pump head must only be opened by staff qualied for mainte-
nance work!
Warning!
1. Children should be supervised to ensure that they do not play
with the appliance.
2. The appliance can be used by children above 8 years as well as
by persons with reduced physical, sensory or mental capacities,
or lack of experience and knowledge, if they have been given
supervision or instruction concerning use of the appliance and
have understood the dangers arising thereof. Children must not
play with the appliance. Cleaning and user maintenance must
not be carried out by children unless they are above 8 years old
and under supervision. Keep the appliance and its cables out of
the reach of children below 8 years of age.
3. If the supply cord is damaged, it must be replaced by the manu-

to avoid a hazard.
Disposal of the unit:
Waste electrical and electronic equipment (WEEE) must not get into
domestic waste!
If ever the unit cannot be used anymore, the consumer is legally obliged
to hand in waste electrical and electronic equipment (WEEE) sepa-
rately from domestic waste, e.g. at a collection point of his community/
his district. This ensures that waste electrical and electronic equipment
(WEEE) is expertly processed and that negative effects to the environ-
ment are avoided.
Therefore electrical and electronic
equipment bears the following symbol:
Kit includes (1)
UVC-Xtreme 800
Filter canister
Filter head
2 lter media baskets
1 sponge
12 pcs sera crystal clear Professional
1,000 ml (290 g/10.2 oz.) sera siporax Professional
1 accessories box
Manual
Contents of the included accessories box:
Connection kit (1.37/1.38), 2 x 1.5 m (4.9 ft.) hoses 16/22 mm
(0.63/0.87 in.), ballast 24 V DC / 2 A, “IN”/“OUT” valves
UVC-Xtreme 1200
Filter canister
Filter head
4 lter media baskets
1 sponge
12 pcs sera crystal clear Professional
2,000 ml (580 g/20.4 oz.) sera siporax Professional
1 accessories box
Manual
Contents of the included accessories box:
Connection kit (1.37/1.38), 2 x 1.5 m (4.9 ft.) hoses 18/23 mm
(0.71/0.91 in.), ballast 24 V DC / 2 A, “IN”/“OUT” valves
000000-00_sera UVC Xtreme 800_1200_INT_GBI.indd 14 07.09.2017 08:12:35

Chat with your sera UVC-Xtreme 800 manual using AI

Get instant AI answers from your sera UVC-Xtreme 800 manual

Ask anything about the sera UVC-Xtreme 800. Answers come from this manual, with the pages they are based on.

UVC-Xtreme 800 Maintenance Schedule

Remind me when maintenance is due
Every 4 weeks
Clean filter media

Wash mechanical and biological filter materials using aquarium water to preserve bacteria. Do not replace all material at once.

Show in the manual (page 17)
Every 6 months
Maintain running unit

Check if the rotor rotates freely by hand and rinse openings with a water stream to remove biofilm or deposits.

Show in the manual (page 17)
Every 9 months
Replace UV-C lamp

Change the amalgam lamp after 1.5 years maximum to ensure full function, even if the indicator light is still on.

Show in the manual (page 17)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend UVC-Xtreme 800?

Yes No

Frequently Asked Questions

A

The UV-C unit is intended for pathogen reduction and floating-algae reduction by irradiating water after it passes through the filter media. The system is not designed to sterilize an aquarium, and beneficial bacteria on the media remain largely unaffected.

Is this answer helpful?

A

Start with a medium performance level and adjust based on your tank size and algae or pathogen pressure. Lower circulation increases the time water spends in the UV-C unit, which can improve reduction. If air is trapped or flow seems weak, increase briefly.

Is this answer helpful?

A

During the first run, trapped air can reach the rotor area and increase noise. Use the suction-pump function to remove air under the filter head. After a few minutes, noise typically decreases once airflow stabilizes.

Is this answer helpful?

A

Mechanical and biological media should be checked and cleaned approximately every 4 to 12 weeks, depending on bioload, feeding, and aquarium volume. If circulation decreases, clean only what is needed and avoid replacing all media at once.

Is this answer helpful?

A

Lamp life depends on switching cycles, but service guidance indicates roughly 1 to 2 years. The lamp should be replaced after about 1.5 years to ensure full performance, especially if the UV-C indicator no longer shows normal operation.

Is this answer helpful?

A

Check that IN/OUT valves are fully open, hoses are not kinked, and media baskets are not clogged. Also verify that the rotor can move freely and that there is not excessive trapped air. If the issue persists, inspect the outlet path and contact a retailer.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Integrated switchable UV-C with amalgam lamp for stabilized performance and higher emission potential
  • Low-voltage, low-noise motor with multiple settings to tune flow, energy use, and UV exposure time
  • Electric suction pump helps purge trapped air after setup or maintenance for quiet operation
  • 360-degree rotatable valves and complete connection kit simplify installation and handling
  • Optimized media basket flow path supports mechanical and biological filtration with long service intervals
VS

Disadvantages

  • Requires careful UV-C safety handling and only original replacement amalgam lamps
  • Performance drops if filter media or hoses clog or if airflow is blocked
  • Correct sealing, upright placement, and proper IN/OUT connections are critical to prevent leaks and air issues
  • Service tasks (rotor and UV-C maintenance) involve disassembly that should be done carefully
M: OA-GPT-54-NAN

Product Specification

Type

External filter with UV-C clarifier

Flow volume

221.95 gal/h

Aquarium size

26.42-211.34 gal

Power consumption

24 W

Features

UV-C lamp, incl. inlet/outlet set

M: GO-GEM-FL-25

Product Description

sera Professional UVC-Xtreme 800 External Filter

The sera Professional UVC-Xtreme 800 External Filter brings UV-C support and electronic control into an efficient, low-noise external filtration system built for freshwater aquariums. Designed for flexible installation, it uses a modern low-voltage motor with multiple performance levels, letting you match water circulation to tank size, bioload, and your desired UV-C treatment intensity. In energy-saving mode, it can run with low wattage while still delivering strong circulation when needed.

What sets the Xtreme series apart is the integrated UV-C unit that is switchable from the control panel. The UV-C amalgam lamp provides stabilized output in its operating temperature range and is intended to reduce pathogens and floating algae more effectively than many conventional UV-C lamps. Rather than aiming for true sterilization, the system focuses on pathogen reduction while preserving beneficial filter bacteria that live primarily in the filter media.

Water flows through optimized media baskets from top to bottom. A ridged sponge helps catch coarse particles, while fine and biological media selections (for example, ceramic biomedia) support mechanical and biofiltration. After passing the media, the mechanically and biologically pre-treated water is drawn to the UV-C zone, then returned to the aquarium via the OUT valve. The system also includes an electric suction pump that helps remove trapped air after setup or maintenance, supporting quiet, reliable operation.

For safe, correct use, consider the sera Professional UVC-Xtreme 800 External Filter Manual when setting up the ballast, positioning the filter, and handling UV-C components. The unit is intended for indoor use, requires sufficient water flow, and includes safety measures to prevent UV-C exposure during maintenance.

Key results

  • UV-C enabled external filtration with switchable control for pathogen and floating-algae reduction
  • Multiple motor performance levels to balance circulation, UV exposure time, and energy use
  • Integrated air removal routine for smoother startups after cleaning
  • Optimized flow path and media baskets to support long service intervals
  • Easy 360-degree valve orientation and included connection kit for flexible setup

Notes

  • Favor partial media cleaning and reuse of established media to protect beneficial bacteria.
  • UV-C amalgam lamps are typically replaced on a service cycle (about 1 to 2 years depending on switching), following the unit guidance.
  • Ensure proper sealing, upright placement, and correct IN/OUT plumbing to maintain flow and efficiency.