5. Measuring Light Sources [Measurement Screen]
5.
Measuring Light Sources
[Measurement Screen]
5-1  Measurement Method
5-1-1  Balancing Color Temperatures of Light Sources
When multiple light sources are being used,
the color temperature of each light source must
be measured separately. If light sources with
different color temperatures are used together
in the same image, inconsistent color will be
present in the shadows and highlights.
Take a measurement by facing the Light
Receptor
❶
towards the light source to
correctly measure the color temperature of the
light source.
NOTICE
●
To get accurate color from a light source, make sure not to get bounced or
reected light from a colored surface, or another light.
●
Damage and dirt on the Light Receptor
❶
can affect the precision of the
measurment. If the Light Receptor
❶
becomes dirty, wipe it with a dry, soft cloth.
Never use organic solvents such as thinner or benzene.
●
Be courteous to those around you that may be sensitive to ash, or bright light,
please give them notice before taking a measurement.
&
Light Receptor
❶

Chat with your Sekonic SpectroMaster C-800 manual using AI

Get instant AI answers from your Sekonic SpectroMaster C-800 manual

Ask anything about the Sekonic SpectroMaster C-800. Answers come from this manual, with the pages they are based on.

SpectroMaster C-800 Maintenance Schedule

As needed
Clean the diffuser

Wipe the diffuser with a dry, soft cloth if dirty. Do not use organic solvents.

Show in the manual (page 96)
As needed
Clean the device exterior

Clean the device with a dry, soft cloth. Never use organic solvents like thinners or gasoline.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend SpectroMaster C-800?

Yes No

Frequently Asked Questions

A

It is used to measure and analyze light quality for photography, video, film, and lighting design. It helps users evaluate color temperature, spectral output, and color rendering for more accurate lighting decisions.

Is this answer helpful?

A

It can measure daylight, tungsten, fluorescent, HMI, LED, and flash light. This wide compatibility makes it useful for both studio and location work.

Is this answer helpful?

A

No. It goes beyond brightness and measures color-related data such as CRI, SSI, TLCI, TLMF, TM-30-15, chromaticity, and filter correction values.

Is this answer helpful?

A

Dark calibration helps the meter stay accurate by resetting its sensor reference. It should be done before first use and whenever temperature conditions change significantly.

Is this answer helpful?

A

Yes. It includes memory functions that let users save measurements, recall them later, and compare current readings with stored reference values.

Is this answer helpful?

A

It is usable by beginners, but its full value is best for users who need advanced lighting analysis. The menu system and many measurement modes may take time to learn.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Measures many light types, including LED, flash, HMI, tungsten, and daylight.
  • Offers advanced metrics like CRI, SSI, TLCI, TM-30-15, and chromaticity data.
  • Touchscreen interface and multiple display modes improve workflow flexibility.
  • Memory and USB software support make it useful for saving and managing readings.
VS

Disadvantages

  • Requires dark calibration and careful setup for best accuracy.
  • Batteries and USB cable may not be included, adding extra cost.
  • Not water-resistant, so it needs protection on set or in transit.
  • Advanced features can feel complex for beginners or casual users.
M: OA-GPT-54-NAN

Product Specification

Type

Light Meter

M: OA-GPT-54-NAN

Product Description

Sekonic SpectroMaster C-800 Light Meter: Precision for Creative Lighting

The Sekonic SpectroMaster C-800 Light Meter Manual points to a tool built for professionals who need more than a basic exposure reading. The C-800 is a high-performance spectrometer designed for photography, video, and film work, giving creators a deeper look into how a light source behaves rather than simply how bright it is.

At its core, the C-800 measures a wide range of lighting types, including natural daylight, LED, HMI, fluorescent, tungsten, and flash. It covers the visible spectrum from 380 nm to 780 nm, making it a strong choice for anyone who cares about color accuracy and repeatable results. This is especially valuable when matching multiple fixtures on set or checking whether a lighting setup will render skin tones and materials naturally.

One of the strongest advantages of this device is its broad set of color-quality metrics. Along with familiar CRI readings, the C-800 also supports SSI, TLCI, TLMF, TM-30-15, chromaticity coordinates, color temperature, and filter compensation tools. That means users can evaluate not just brightness, but also spectral quality, color shift, and the practical corrections needed to reach a target white balance.

The touchscreen interface and multiple display modes make the meter flexible in real-world production. Users can switch between text views, spectrum graphs, comparison modes, multi-light analysis, and white-balance correction views. The ability to save measurements, recall reference values, and connect via USB for software support adds another layer of workflow convenience.

For creators working in fast-paced environments, the C-800 is also about control. It includes dark calibration, adjustable settings, battery monitoring, and memory functions that help keep measurements organized. The meter is best suited for experienced users who need reliable lighting data for studio work, broadcast, set design, or architectural lighting projects.

If you are looking for a tool that bridges exposure metering and advanced color analysis, the Sekonic SpectroMaster C-800 stands out as a serious professional solution.

Notes

  • Batteries and USB cable may need to be purchased separately.
  • Dark calibration is important for accurate readings.
  • The device is not water-resistant and should be handled carefully.