750 viva Maintenance Schedule
Have the scale serviced by an authorized service partner every 3 to 5 years depending on usage frequency.
Have the scale serviced by an authorized service partner every 3 to 5 years depending on usage frequency.
Visually inspect the weighing platform before every measurement with direct skin contact.
Clean and disinfect the weighing platform after every measurement with direct skin contact using a soft cloth and suitable agents.
Clean the scale ring and viewing window if required during hygiene reprocessing.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend 750 viva?
Yes NoDo you recommend 750 viva?
Yes NoFrequently Asked Questions
No, sterilization is not allowed. Use disinfectants suitable for acrylic plastic surfaces to maintain the device.
Is this answer helpful?
Turn the adjusting wheel until the pointer reads zero before weighing starts to ensure accuracy.
Is this answer helpful?
Use chlor and alcohol free disinfectants suitable for acrylic and sensitive surfaces only.
Is this answer helpful?
Maximum load is 150 kg or 320 lbs depending on the model configuration and settings.
Is this answer helpful?
Recommended servicing intervals are every 3 to 5 years depending on usage frequency.
Is this answer helpful?
No, soft floor coverings may cause incorrect measurements. Place on a firm flat surface.
Is this answer helpful?
There is a two-year warranty from the date of delivery for material or workmanship defects.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- High precision mechanical load lever system ensures consistent readings without power.
- Easy to clean with removable scale ring for deep cleaning of the dial.
- Durable design suitable for hospital environments with long operational life.
- Clear analog displays allow quick and easy reading of weight values.
- Includes transport lock for safe moving and prevents force shunts.
Disadvantages
- Requires manual zero adjustment before each use to ensure accuracy.
- No digital data integration capability for modern electronic medical record systems.
- Sterilization is strictly not permitted on this device model.
- Requires regular servicing every 3 to 5 years depending on usage frequency.
- Weight capacity limited to 150 kilograms maximum for most variants.
Product Specification
Operating Mode
Without Battery
Material
Plastic
Color
white
Weight Capacity
330.69 lbs
Resolution
2.20 lbs
Units
lbs
Memory Function
No
Display
No
Platform Size
11.42x11.42in (WxD)
Product Description
The seca 750 Viva Analog Person Scale
Achieving accurate patient weight measurements is fundamental in modern healthcare settings. The seca 750 viva analog Person Scale provides a reliable solution for medical professionals who require robust and precise weighing results. This mechanical dial scale is designed for use in hospitals, clinics, and nursing facilities where hygiene and durability are paramount. Unlike digital alternatives, this model relies on mechanical stability to ensure functionality in various environments without power consumption. The seca 750 viva analog Person Scale Manual offers detailed setup instructions for initial use.
Understanding the operation of this device is essential for maintaining patient safety and data accuracy. The manufacturer provides comprehensive guidance for proper calibrations and handling. These instructions ensure users know how to properly calibrate the zero point and handle the device with care. The mechanical load lever system guarantees consistent readings without the need for batteries or digital components, which reduces maintenance needs significantly over time.
Hygiene is a critical component of medical equipment usage. The design allows for easy cleaning to prevent cross-contamination between patients. The scale ring can often be removed for deep cleaning of the dial, though model specifics vary by variant. Users must avoid harsh chemicals or sterilization methods as these can damage sensitive plastic surfaces. Instead, mild detergents and appropriate disinfectants are recommended for daily maintenance to keep the unit in good condition. Medical professionals operate this device exclusively.
Setup involves removing the transport lock and ensuring the scale sits on a firm level surface. Soft carpets can interfere with measurements, so placement on hard flooring is necessary for correct data. The pointer display offers clear visibility of weight values instantly, which supports efficient workflow during consultations. Regular maintenance checks help preserve the accuracy of the instrument over its long operational life. Support for patients with limited motor skills is crucial during use.
Safety precautions emphasize supporting patients during weight checks to prevent falls. The scale supports up to 150 kilograms for most models in this series. Always verify the pointer reads zero before placing a patient on the platform to avoid errors. By following standard operating procedures, healthcare providers can trust the readings generated by this durable mechanical scale. Two years warranty covers material defects.
Key Features
The device includes a transport lock that doubles as a wall spacer. This helps prevent force shunts where the scale touches a wall during use. It is classified as a Class II medical device with measuring function. The zero adjustment range covers significant weights allowing flexibility during different weighing tasks.
Usage and Care
Before each use, a function check is mandatory per safety guidelines. Inspect for mechanical damage and ensure the display moves freely. Cleaning should avoid alcohol based products which might degrade acrylic glass. Proper storage keeps the original packaging handy for future transport needs. This ensures longevity and protects against physical damage during shipping.
Technical Specifications
Dimensions vary slightly between models but generally fit compactly in exam rooms. Temperature ranges allow operation in standard climate control environments. Humidity levels must be managed to prevent condensation on sensitive parts. Weighing results can be converted between pounds and kilograms using a table provided. This versatility makes it suitable for international or mixed patient populations.
Conclusion
Investing in quality equipment reduces error rates and increases patient trust. The seca 750 remains a standard choice for many clinics. Follow the manual strictly for optimal performance and safety compliance. Regular servicing keeps it calibrated according to national regulations. This concludes the overview of this weighing system. Maintenance every 3 to 5 years recommended.