3. Usage and Application Scope
NOVA-EX 03.5619 of AC work light (abbre.Explosion-proof light in the following instruction) is suitable for using
in explosive area of Zone 1, Zone 2, Zone 21, Zone 22, gas group IIA/IIB/IIC, dust group IIIA/IIIB/IIIC and Temperature
Group T1~T6/T85°C. It is suitable for using in temporary local auxiliary lighting and local main lighting for the
industries of petroleum produce, smelting, chemical, pharmaceutical, brewing, military reserve, etc.
4. STRUCTURE
• Explosion-proof cavity which includes the light source gluing contact surface cannot be repaired if any damage or
crack happens.
• The threads of explosion-proof cavity for the switch part cannot be repaired if any damage or crack happens.
• The cylinder part of explosion-proof cavity for the switch part cannot be repaired if any damage or crack happens.
5. INSTRUCTION
• Before use, please check whether the packing is in good condition, if there is any visible damage of the light and
charger. For the flood light, please check if there is any visible damage of the structure or “abnormal sound”
inside. Please open the light to check if the damage will influence the explosion-proof performance and make
appropriate treatment.
• Please check if the explosion-proof light nameplate parameters listed are conformed to the actual conditions of
use.
• The explosion-proof light is with angle adjusting function from 0。-180。 to meet a variety of angle lighting
orientation.
• The explosion-proof light is with three modes Low, High, OFF. Press first “Low”, second “High”, third “OFF”.
• The power part is cast sealed. Stop use the light when the cast sealing material turn soft, crack and expand.
• When wiring, make sure there is no absent of the seal ring, the retainer ring and the compression nut in the cable
leading device. The cable which goes through the leading device should be grounded. Tighten the compression
nut at last.
• The following operations are prohibited in any possible dangerous area:
Open the light when it is working or turning off the load.
Regular or occasional maintenance and repair.
• The persons who use the light at site should know about the performance of explosion-proof light. Turn off the
light in time and evacuate the dangerous area when find any abnormal phenomenon. Unqualified repair person is
not allowed to repair the explosion-proof lights.
6. MAINTENANCE
• The service man must have on-the-job training to know the specification and operating performance of
explosion-proof light. They must have professional knowledge and should familiar with the structure of
explosion-proof light.
• Clean the dust and dirt on the shell of the explosion-proof light regularly to improve the luminous efficacy and
heat dispersion performance. A wet cloth can be used for cleaning.
• Check whether the transparent parts have been impacted by foreign body regularly. Check whether the fasteners
and inner components are loose, soldering off or corroded. If yes, do not use it until maintained.
• If use the light in damp environment, please regularly check and change the sealing components to ensure the
protective performance of the shell.
• When the cast sealing material turn soft, crack and expand obviously, please change the power immediately.
• The sealing ring, retainer ring and compression nut in the cable leading device cannot be omitted, miss
assembling of any part of them, or easily discarded.
• When disassemble the light, must comply with the warning requirements to operate in non-dangerous area.
• After open the shell, should check whether the sealing components become hard or adhesive; whether the
insulating layer of the wire become green or carbonized; whether the insulating parts and electrical components
become deformed or have scorch. If these problems are found, must repair the light immediately.
• The model, specification, dimension and performance of the parts for maintaining should keep the same as the
original ones.
• Before closing the shell, should use replacement type anti rust oil on the explosive-proof threads and check
whether the sealing ring is at the original location by achieve the sealing function when close the shell.
• Do not disassemble the sealing parts of the light often. Otherwise the explosive-proof function will be affected.

Chat with your Scangrip NOVA-EX manual using AI

Get instant AI answers from your Scangrip NOVA-EX manual

Ask anything about the Scangrip NOVA-EX. Answers come from this manual, with the pages they are based on.

NOVA-EX Maintenance Schedule

Regularly
Clean dust and dirt from the light shell

Remove dust and dirt regularly to improve luminous efficacy and heat dispersion. Use a wet cloth for cleaning.

Regularly
Inspect transparent parts and fasteners

Check if transparent parts have been impacted by foreign bodies. Verify that fasteners and inner components are not loose, soldering is intact, and there is no corrosion.

Regularly
Check and replace sealing components in damp environments

If used in damp environments, regularly check and change sealing components to ensure the protective performance of the shell.

Before closing shell
Apply anti-rust oil to explosion-proof threads

Use replacement type anti-rust oil on explosion-proof threads before closing the shell to maintain integrity.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend NOVA-EX?

Yes No

Frequently Asked Questions

A

Yes, the light has II 2G Ex db eb mb certification. It is approved for Zone 1, Zone 2, Zone 21, and Zone 22 areas containing gases or dust.

Is this answer helpful?

A

Never open the light in dangerous zones. It must be opened in a safe, non-dangerous location to maintain explosion-proof integrity.

Is this answer helpful?

A

It has three modes: Low, High, and Off. You can select them by pressing the switch once or twice.

Is this answer helpful?

A

The standard cable provided is 10 meters long. It should be grounded and secured with the compression nut.

Is this answer helpful?

A

Yes, the unit allows for an angle adjustment range of 0 to 180 degrees to direct light where needed.

Is this answer helpful?

A

Stop use immediately. If the casting sealing material becomes soft, cracks, or expands, the device poses a safety risk.

Is this answer helpful?

A

Always use parts produced or appointed by the manufacturer. Using non-standard parts will destroy explosion-proof performance.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Complies with IECEx and ATEX standards for hazardous zones
  • High output of 3400 lumens for clear visibility
  • IP65 rated protection against water and dust ingress
  • Adjustable beam angle up to 180 degrees for flexibility
  • Wide input voltage range from 100V to 240V AC
VS

Disadvantages

  • Heavy weight of 5.3 kg makes handling difficult
  • Explosion-proof cavity cannot be repaired if cracked
  • Repairs must be authorized by manufacturer only
  • Sealing material requires regular inspection and replacement
  • Restricted maintenance zones to non-dangerous environments
M: QW-35-FL

Product Specification

Operating Time

4 hours

Charging Time

3 hours

Dimensions (WxHxD)

10.63x10.28x5.12 inches

M: QW-35-FL

Product Description

Scangrip Nova-EX LED Construction Floodlight Review

When searching for robust lighting solutions, the Scangrip Nova-EX LED Construction Floodlight Manual offers crucial data for safety and operation. It is a powerful lighting solution designed specifically for construction sites requiring hazardous area safety and high visibility. The unit features a COB LED source providing significant brightness suitable for large industrial zones where standard lights might fail due to strict safety regulations. Understanding the text is essential for safe deployment.

Reliability in Harsh Conditions

Constructed with durability in mind, this floodlight boasts an IP65 rating against water and dust ingress ensuring it survives rain or dusty environments effectively. Its explosion-proof capability ensures safety in Zone 1, Zone 2 as well as Zone 21 and Zone 22 areas containing flammable gases or dust. The enclosure is robust, weighing approximately 5.3 kg to ensure stability on the ground or mounting platforms without tipping over during operation. It functions reliably within a temperature range of -20 to +45 degrees Celsius.

Power and Control

Powering the unit requires an AC input compatible with global voltages ranging from 100V to 240V making it versatile across different regions and power grids. Users can adjust the beam angle from 0 to 180 degrees to direct light exactly where needed without moving the whole unit excessively. The three operation modes allow switching between low, high, and off settings conveniently via a single button interface. The light outputs 3400 lumens at high power, delivering intense illumination for night work or dark warehouses effectively. The color temperature is 6000K for high visibility. It comes with a 10m cable.

Maintenance and Safety Warnings

Proper maintenance is vital to preserve the explosion-proof integrity of the housing permanently. Do not open the light in dangerous areas or during operation under any circumstances. Only use replacement parts supplied by the manufacturer to maintain certifications and safety ratings. The sealing material must be checked regularly to prevent moisture entry or degradation caused by UV exposure. If the casting material softens or cracks, stop using the device immediately to avoid risk to personnel. Professional training is required for repairs and they must occur in safe locations away from hazards.

Conclusion and Compliance

The Nova-EX series remains a staple for industrial lighting needs globally across many sectors. Ensure you check all safety protocols before installation as outlined in the detailed documentation provided. This product supports various industries including petrochemical, pharmaceutical, and mining operations requiring certified equipment for risk reduction. Always read the instruction manual thoroughly before first use to ensure compliance with local regulations and standards. Verify cable integrity for grounding requirements to ensure electrical safety and avoid accidental disconnection.