3. Usage and Application Scope
Rechargeable handheld EX PROOF work light is a rechargeable and portable explosion-proof handle light
(abbre.Explosion-proof light in the following instruction), suitable for using in explosive area of Zone 2, Zone 22,
Gas group IIA/IIB/IIC, dust group IIIA/IIIB/IIIC and Temperature Group T1~T5/T100℃. It is suitable for using in
temporary local auxiliary lighting and local main lighting for the industries of petroleum produce, smelting, chemical,
pharmaceutical, brewing, military reserve, etc.
4. INSTRUCTION
• Before use, please check whether the packing is in good condition, if there is any visible damage of the light and
adapter. Before using the light, please check if there is any visible damage of the structure or “abnormal sound”
inside. Please open the light to check if the damage will influence the explosion-proof performance and make
appropriate treatment.
• Please check if the explosion-proof light nameplate parameters listed are conformed to the actual conditions of
use.
• The explosion-proof light is composed of work light and adaptor.
• The explosion-proof light is with magnetic base/foldable stand and hook. It can be adjusted in different direction
and easily, quickly use with the hook.
• The explosion-proof light is with four modes: Top, Low, High, OFF. Press first “Top”, second “Low”, third “High”,
fourth “OFF”.
• Please charge the light under the circumstance between 0° C to +45° C. Please pay attention to the orders when
charging. First, please make sure the effective connection between the light and adapter. Second, plug the
adaptor to AC power supply. The conversed operation is prohibited.
• The explosion-proof light has charging indication function: the charging indicator will be on “red” during charging,
and the charging indicator turns to be “green” when it is fully charged.
• The following operations are prohibited in any possible dangerous area:
Open the light when it is working or turning off the load.
Regular or occasional maintenance and repair.
• Operating under explosive atmosphere, fasten protection cap of charger, do not open the protection cap under
explosive atmosphere.
• The persons who use the light at site should know about the performance of explosion-proof light. Turn off the
light in time and evacuate the dangerous area when find any abnormal phenomenon. Unqualified repair person is
not allowed to repair the explosion-proof lights.
5. MAINTENANCE
• When installation, use and maintenance, observe following standards IEC 60079-10, IEC60079-14, IEC60079-17
and IEC 60079-19
• The service man must have on-the-job training to know the specification and operating performance of
explosion-proof light. They must have professional knowledge and should familiar with the structure of explosion-
proof light.
• Clean the dust and dirt on the shell of the explosion-proof light regularly to improve the luminous efficacy and
heat dispersion performance. A wet cloth can be used for cleaning.
• Check whether the transparent parts have been impacted by foreign body regularly. Check whether the
fasteners and inner components are loose, soldering off or corroded. If yes, do not use it until maintained.
• If use the light in damp environment, please regularly check and change the sealing components to ensure the
protective performance of the shell.
• When disassemble the light, must comply with the warning requirements to operate in non-dangerous area.
• After open the shell, should check whether the sealing components become hard or adhesive; whether the
insulating layer of the wire become green or carbonized; whether the insulating parts
and electrical components become deformed or have scorch. If these problems are found, must repair the light
immediately.
• The model, specification, dimension and performance of the parts for maintaining should keep the same as the
original ones.
• Check whether the sealing ring is at the original location by achieve the sealing function when close the shell.
• Do not disassemble the sealing parts of the light often. Otherwise the explosive-proof function will be affected.

Chat with your Scangrip MIDI-EX manual using AI

Get instant AI answers from your Scangrip MIDI-EX manual

Ask anything about the Scangrip MIDI-EX. Answers come from this manual, with the pages they are based on.

MIDI-EX Maintenance Schedule

Regularly
Clean dust and dirt from the light shell

Use a wet cloth to remove dust and dirt regularly to improve luminous efficacy and heat dispersion performance.

Regularly
Inspect transparent parts and internal components

Check for impact damage on transparent parts and ensure fasteners or inner components are not loose, desoldered, or corroded.

Regularly (if in damp environments)
Check and replace sealing components

If used in damp environments, regularly check and change sealing components to ensure the protective performance of the shell.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend MIDI-EX?

Yes No

Frequently Asked Questions

A

The battery is a 3.8V 1600mAh Li-ion pack. It provides up to 5 hours of runtime on low settings and about 2.5 hours on high settings. Ensure you use only compatible Scangrip adapters for charging.

Is this answer helpful?

A

Yes, it is certified for Zone 2 and Zone 22 dangerous areas. It is suitable for explosive atmospheres involving gases and dust but must comply with relevant laws and regulations for safety.

Is this answer helpful?

A

No. You must never charge the battery in a hazardous location. Always charge in a non-dangerous environment between 0 and 45 degrees Celsius to ensure safety and battery integrity.

Is this answer helpful?

A

The device has an IP65 rating. This means it is dust-tight and protected against water jets from any direction, making it suitable for harsh industrial environments.

Is this answer helpful?

A

No. Only trained professionals should perform maintenance or repair. You must use original parts from Scangrip A/S to maintain the explosion-proof performance.

Is this answer helpful?

A

There are four modes: Top, Low, High, and OFF. You cycle through them by pressing the button once, twice, thrice, or four times respectively.

Is this answer helpful?

A

The product is guaranteed for two years from the date of purchase. This guarantee becomes invalid if the product is misused or tampered with.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Certified for Zone 2 and Zone 22 hazardous locations.
  • Rechargeable Li-ion battery offers up to 5 hours runtime.
  • IP65 rating ensures protection against dust and water jets.
  • Compact 181g design is lightweight and easy to carry.
  • Includes magnetic base, hook, and foldable stand for mounting.
VS

Disadvantages

  • Charging must only be performed in safe non-hazardous zones.
  • Only original Scangrip parts can be used for maintenance.
  • Maintenance and repair must be done by trained professionals.
  • Not suitable for Zone 1 areas without specific additional certification.
  • Battery must be charged within specific temperature limits.
M: QW-35-FL

Product Specification

Power Source

Battery 3.8V 1.6Ah Li-Ion

Light Source

LED, daylight white (6000K), 200lm

Features

IP65, adjustable head, dimmable, hanging hook, magnetic holder, stick lamp

Runtime

5h

Charge Time

3.5h

Dimensions (WxHxD)

1.81x7.17x1.14in

Weight

0.40lbs

Package Contents

USB charging cable

M: QW-35-FL

Product Description

The Scangrip Midi EX LED Battery Work Light Manual Essentials

When working in hazardous environments, safety and reliability are paramount for every professional. The Scangrip Midi EX LED Battery Work Light is engineered for individuals requiring dependable illumination in dangerous zones. This rechargeable handheld light ensures visibility where it matters most, whether in petrochemical industries, smelting plants, chemical manufacturing, or military reserves. Its compact design makes it easy to carry during long shifts without adding weight to your gear.

Safety Certifications and Compliance

One standout feature is its robust safety certification profile. It meets stringent standards for Zone 2 and Zone 22 areas, making it suitable for potentially explosive atmospheres involving gases like IIA, IIB, and IIC, as well as dust groups IIIA, IIIB, and IIIC. The equipment protection level II 3G Ex ic IIC T5 Gc applies to gases, while II 3D Ex ic IIIC T100°C Dc covers specific dust groups. Users must adhere to strict safety protocols, such as not opening the unit when an explosive atmosphere is present or charging the battery in hazardous locations. Compliance with local laws and regulations is mandatory.

Performance and Battery Life

Powered by a rechargeable 3.8V 1600 mAh Li-ion battery, the light offers substantial runtime for daily operations. Users can expect approximately two and a half to five hours of continuous operation depending on the selected mode. It features a combination of a COB LED and a spot SMD LED, providing flexibility with different lighting modes to suit specific tasks. The intensity ranges from one hundred to two hundred lumens on standard settings, with a spot capability reaching higher lux levels. This versatility allows workers to adjust brightness based on the immediate task at hand, conserving power when full beam intensity is not needed.

Durability and Design

Built to withstand tough industrial conditions, the Midi EX boasts a solid IP65 rating, ensuring it is dust-tight and protected against water jets from any direction. The casing measures 181.8 by 46 by 29 millimeters and weighs 181 grams, balancing portability with sturdiness. A built-in magnetic base, foldable stand, and hook allow for versatile mounting options, keeping hands free for other complex tasks while illuminating the workspace effectively.

Important Maintenance and Usage Notes

Regular maintenance is crucial for preserving explosion-proof capabilities over the long term. Always inspect the shell for cracks and ensure sealing rings are intact before use. Cleaning should be done with a wet cloth, avoiding damage to transparent parts. Using non-original parts can void the safety rating and compromise intrinsic safety levels. The charger indicator changes from red to green when fully charged. Always charge within the temperature range of zero to forty-five degrees Celsius.

Note: Always read the manual before use and ensure you are qualified to operate explosion-proof equipment. Safety is the top priority.

M: QW-35-FL

© Copyright 2026 Manual.ly