Manual.ly Logo

Saunier Duval VivAir SDH 17-025 NW Manual

0.0 · 0 Ratings

PDF manual · 136 Pages

English

M: OA-GPT-54-NAN
page

/ 136

Loading...
40dde970a265fb686f79767421fe06ad7f2f page 2c
SDH17-NW-U_EN - 05/14 - Saunier Duval
- 20 -
MAINTENANCE
EN
10 Maintenance
e
DANGER:
Danger of electric shock.
Disconnect the unit and isolate the mains supply before
proceeding to carry out maintenance on the unit.
Ensure the the mains supply cannot be reconnected
inadvertently. This will prevent injuries..
e
DANGER:
Danger of electric shock.
Do not clean the unit with water.
b
WARNING:
Danger of breakdowns or malfunction.
Do not use gasoline, benzine, thinner or cleansers
when cleaning the unit. It may damage the coating of
the unit.
b
WARNING:
Hot water over 40ºC may cause discoloring or
deformation.
10.1 Cleaning the remote controller
• Wipe the controller with a dry cloth. Do not use water to
clean the remote controller.
• Do not use glass cleaners or chemical cloths.
10.2 Cleaning the indoor unit
• Wipe the outer part of the unit with a soft and dry cloth.
• For difcult stains, use a neutral detergent diluted in water.
Eliminate the excess of water form the cloth before wiping.
Leave the unit clean from any detergent.
10.3 Cleaning the air lters
The air lter traps the dust circulated from the room into the
indoor unit.
If the lter becomes blocked, the air conditioner's efciency will
be reduced, the compressor could be damaged and the indoor
unit's heat exchanger coil could freeze up.
Clean the air lter regularly to prevent this from happening. In
order to do so:
• Remove the air lters by slightly pushing up the center tab
until it is released from the stopper and remove the lter
downwards.
• Clean the lter removing the dust or the dirt using a vacuum
cleaner or cleaning them with cold water.
• Ensure that the lters are dried completely (dry in the shade)
before putting them back into the unit. The activated carbon
lters (where tted) can be reactivated by placing in direct
sunlight. If strange odours are still smelt replace with new. If
strong odours continue to be a problem, contact your after
sales service provider to fully clean the unit.
• Attach the lter correctly and make sure it is completely xed
behind the stopper. If the right and left lters are not properly
xed, this could cause a malfunction.
b
WARNING:
Danger of breakdowns or malfunction.
Do not attach perfume systems, anti-odour systems
etc. in the lter or in the inside air return.
This can damage and soil the heat exchanger coil. If
necessary, install these systems at the unit's outlet
point and ensure they only run when the fan is on.
10.4 Cleaning the Outdoor Unit
b
WARNING:
Always use suitable personal protection equipment
(helmet, gloves, safety boots and protective glasses).
• Wipe the outer part of the unit with a dry cloth.
• Occasionally remove dust and leaves from the inlet surface.
• Periodically clean the heat exchanger ns with a soft brush
when the unit is located in a dusty environment.
• Occasionally check the base of the outdoor unit.
e
DANGER OF INJURY AND PHYSICAL DAMAGE!
A damaged or deteriorated base could make the unit
unstable and potentially cause physical or material
damage.
e
DANGER OF INJURY AND PHYSICAL DAMAGE!
Except for servicing or replacement, do not dismantle
the outdoor unit outlet. Exposing the fan can be very
dangerous.
i
NOTE:
We advise you to contact a reliable air conditioner
specialist or the Saunier Duval Group Technical
Service to contract a preventative maintenance service.
This will help to prolong the life of your equipment and
improve its performance.

Chat with your Saunier Duval VivAir SDH 17-025 NW manual using AI

Get instant AI answers from your Saunier Duval VivAir SDH 17-025 NW manual

Ask anything about the Saunier Duval VivAir SDH 17-025 NW. Answers come from this manual, with the pages they are based on.

VivAir SDH 17-025 NW Maintenance Schedule

Every 15 days
Clean the air filters

Remove dust and dirt using a vacuum cleaner or cold water. Ensure filters are completely dry before reinserting.

Show in the manual (page 43)
Occasionally
Clean the outdoor unit inlet surface

Remove dust and leaves from the inlet surface occasionally to maintain airflow.

Show in the manual (page 44)
Periodically
Clean heat exchanger fins

Clean fins with a soft brush if the unit is in a dusty environment.

Show in the manual (page 44)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend VivAir SDH 17-025 NW?

Yes No

Frequently Asked Questions

A

It is a wall-mounted air-to-air heat pump that provides both cooling and heating. It also includes dehumidifying and fan-only modes for more flexible indoor comfort.

Is this answer helpful?

A

The unit is mainly controlled with an infrared remote control. You can adjust mode, temperature, fan speed, airflow direction, timer settings, sleep mode, and turbo function.

Is this answer helpful?

A

AUTO mode lets the unit choose between cooling and heating based on room temperature. It is useful when you want simple everyday operation without frequent manual adjustments.

Is this answer helpful?

A

The filters should be cleaned regularly, and the manual suggests checking them about every 15 days. Clean filters help maintain airflow, efficiency, and overall performance.

Is this answer helpful?

A

X-FAN keeps the indoor fan running briefly after cooling or drying. This helps remove remaining moisture from the indoor unit and reduces the risk of mold and odors.

Is this answer helpful?

A

Yes. The auto restart function restores the unit to its previous settings after power returns, which adds convenience and helps maintain comfort with less manual input.

Is this answer helpful?

A

First check the batteries and replace both at the same time if needed. If the problem continues, remove and reinsert the batteries after a few minutes or use emergency operation temporarily.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Heat pump operation supports both cooling and heating from one compact wall-mounted unit.
  • Inverter technology helps adapt output to demand, improving efficiency and comfort.
  • Useful functions like Sleep, Timer, Turbo, and X-FAN improve convenience and hygiene.
  • Auto restart and anti-freeze features add reliability after power cuts and in winter use.
VS

Disadvantages

  • Performance depends on regular cleaning and proper maintenance of filters and airflow paths.
  • Remote control use is essential for most settings, so misplacement can reduce convenience.
  • High humidity during cooling or drying may cause moisture to appear at the outlet louvres.
  • Timer and clock functions must be set correctly to work as intended after battery changes.
M: OA-GPT-54-NAN

Product Specification

Type

1x indoor unit, 1x outdoor unit

Energy efficiency class

A+ (cooling), A (heating)

Energy efficiency rating

5.6 (SEER), 3.8 (SCOP)

Cooling capacity

9,212 BTU/h

Heating capacity

9,554 BTU/h

Features

Timer, sleep mode, air filtration, heating function

Refrigerant

R410a

Indoor unit mounting type

Wall mounting

Outdoor unit mounting type

Freestanding

Indoor unit noise level

41dB(A)

Outdoor unit noise level

51dB(A)

Indoor unit dimensions

33.27x10.83x7.09in (WxHxD)

Outdoor unit dimensions

27.99x21.26x10.12in (WxHxD)

Indoor unit weight

19.84 lb

Outdoor unit weight

61.73 lb

Scope of delivery

Remote control

M: OA-GPT-54-NAN

Product Description

Saunier Duval SDH17-025 NW VivAir: Practical Comfort for Everyday Spaces

The Saunier Duval SDH17-025 NW VivAir is a wall-mounted air-to-air heat pump designed to bring flexible climate control to homes and small offices. Built for both cooling and heating, it combines straightforward operation with a compact indoor unit, making it a smart choice for users who want comfort without complicated routines.

One of its strongest points is versatility. In AUTO mode, the system adapts to the room temperature and selects cooling or heating as needed. That makes daily use simple, while the COOL, DRY, FAN, and HEAT modes give more control when you want to fine-tune performance. The remote control is central to the experience, offering access to temperature settings, fan speed, airflow direction, timer functions, sleep mode, and turbo operation.

Efficiency is another major advantage. The inverter-driven design helps match power output to demand, which supports lower energy use and smoother operation. The heat pump function also stands out, since it can transfer heat rather than generate it from scratch. For many users, that means a more economical way to stay warm in colder months. The system also uses R-410A refrigerant and includes features such as auto restart, anti-freeze protection, and valve shielding for added practicality.

The VivAir line is clearly built with comfort and maintenance in mind. The anti-dust filter helps reduce circulating particles, while the X-FAN function keeps the indoor unit dry after cooling or dehumidifying, helping limit moisture buildup. Sleep mode adjusts temperature gently overnight, and the timer lets you plan operation around your routine. The result is a unit that feels modern, responsive, and thoughtfully designed.

If you are comparing compact climate solutions and looking for the Saunier Duval SDH17-025 NW VivAir Manual, it is especially useful for understanding setup, remote control functions, cleaning steps, and energy-saving tips. Those details show that this model is not only about cooling and heating, but also about long-term reliability and sensible everyday use.

Notes

  • Best suited for residential and office environments.
  • Regular filter cleaning helps preserve performance.
  • Proper installation and periodic servicing are important for safe operation.
  • Always keep airflow paths clear for the best results.
M: OA-GPT-54-NAN

© Copyright 2026 Manual.ly