Manual.ly Logo

Saunier Duval VivAir SDH 17-025 NW Manual

0.0 · 0 Ratings

PDF manual · 136 Pages

English

M: OA-GPT-54-NAN
page

/ 136

Loading...
40dde970a265fb686f79767421fe06ad7f2f page 1d
SDH17-NW-U_EN - 05/14 - Saunier Duval
- 5 -
INTRODUCTION
EN
INTRODUCTION
1 Your safety
1.1 Symbols used
a
DANGER:
Direct danger for life and health.
e
DANGER:
Danger electric shock.
b
WARNING:
Potentially dangerous situation for the product and the
environment.
i
NOTE:
Useful information and indications.
1.2 Correct use of the unit
This unit has been designed and manufactured for the sole
purpose of providing cooling and heating in occupied residential
and commercial premises. The use thereof for other domestic
or industrial purposes shall be the exclusive responsibility of the
persons specifying, installing or using them in that way.
Prior to handling, installing, start up, using or performing
maintenance on the unit, the persons assigned to perform
these tasks should be familiar with all the instructions and
recommendations set forth in the unit's installation manual.
i
NOTE:
Keep the manuals throughout the service life of the
unit.
i
NOTE:
The information relating to this unit is divided between
two manuals: installation manual and user manual.
i
NOTE:
This equipment contains R-410A refrigerant. Do not
vent R-410A into atmosphere: R-410A, is a uorinated
greenhouse gas, covered by Kyoto Protocol, with a
Global Warming Potential (GWP) = 1975.
i
NOTE:
The refrigerant uid contained in this equipment must
be properly recovered for recycling, reclamation or
destruction before the nal disposal of the equipment.
i
NOTE:
The relevant personnel performing any service of
maintenance operations involving the handling of the
refrigerant uid must have the necessary certication to
comply with all local and international regulations.
2 Extreme operating conditions
This unit has been designed to operate within the range of
temperatures indicated on Figure 2.1. Ensure that these ranges
are not exceeded.
Heating
Outdoor Indoor
Cooling
Fig. 2.1 Operating ranges of the unit.
Legend
D.B. Temperature measured by dry bulb method
The working capacity of the unit changes depending on the
working temperature of the outdoor unit.
3 Identication of the unit
This manual is valid for the Split system series. In order to
know the specic model of your unit please refer to the unit
nameplates.
The nameplates are located on the outdoor and indoor units.

Chat with your Saunier Duval VivAir SDH 17-025 NW manual using AI

Get instant AI answers from your Saunier Duval VivAir SDH 17-025 NW manual

Ask anything about the Saunier Duval VivAir SDH 17-025 NW. Answers come from this manual, with the pages they are based on.

VivAir SDH 17-025 NW Maintenance Schedule

Every 15 days
Clean the air filters

Remove dust and dirt using a vacuum cleaner or cold water. Ensure filters are completely dry before reinserting.

Show in the manual (page 43)
Occasionally
Clean the outdoor unit inlet surface

Remove dust and leaves from the inlet surface occasionally to maintain airflow.

Show in the manual (page 44)
Periodically
Clean heat exchanger fins

Clean fins with a soft brush if the unit is in a dusty environment.

Show in the manual (page 44)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend VivAir SDH 17-025 NW?

Yes No

Frequently Asked Questions

A

It is a wall-mounted air-to-air heat pump that provides both cooling and heating. It also includes dehumidifying and fan-only modes for more flexible indoor comfort.

Is this answer helpful?

A

The unit is mainly controlled with an infrared remote control. You can adjust mode, temperature, fan speed, airflow direction, timer settings, sleep mode, and turbo function.

Is this answer helpful?

A

AUTO mode lets the unit choose between cooling and heating based on room temperature. It is useful when you want simple everyday operation without frequent manual adjustments.

Is this answer helpful?

A

The filters should be cleaned regularly, and the manual suggests checking them about every 15 days. Clean filters help maintain airflow, efficiency, and overall performance.

Is this answer helpful?

A

X-FAN keeps the indoor fan running briefly after cooling or drying. This helps remove remaining moisture from the indoor unit and reduces the risk of mold and odors.

Is this answer helpful?

A

Yes. The auto restart function restores the unit to its previous settings after power returns, which adds convenience and helps maintain comfort with less manual input.

Is this answer helpful?

A

First check the batteries and replace both at the same time if needed. If the problem continues, remove and reinsert the batteries after a few minutes or use emergency operation temporarily.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Heat pump operation supports both cooling and heating from one compact wall-mounted unit.
  • Inverter technology helps adapt output to demand, improving efficiency and comfort.
  • Useful functions like Sleep, Timer, Turbo, and X-FAN improve convenience and hygiene.
  • Auto restart and anti-freeze features add reliability after power cuts and in winter use.
VS

Disadvantages

  • Performance depends on regular cleaning and proper maintenance of filters and airflow paths.
  • Remote control use is essential for most settings, so misplacement can reduce convenience.
  • High humidity during cooling or drying may cause moisture to appear at the outlet louvres.
  • Timer and clock functions must be set correctly to work as intended after battery changes.
M: OA-GPT-54-NAN

Product Specification

Type

1x indoor unit, 1x outdoor unit

Energy efficiency class

A+ (cooling), A (heating)

Energy efficiency rating

5.6 (SEER), 3.8 (SCOP)

Cooling capacity

9,212 BTU/h

Heating capacity

9,554 BTU/h

Features

Timer, sleep mode, air filtration, heating function

Refrigerant

R410a

Indoor unit mounting type

Wall mounting

Outdoor unit mounting type

Freestanding

Indoor unit noise level

41dB(A)

Outdoor unit noise level

51dB(A)

Indoor unit dimensions

33.27x10.83x7.09in (WxHxD)

Outdoor unit dimensions

27.99x21.26x10.12in (WxHxD)

Indoor unit weight

19.84 lb

Outdoor unit weight

61.73 lb

Scope of delivery

Remote control

M: OA-GPT-54-NAN

Product Description

Saunier Duval SDH17-025 NW VivAir: Practical Comfort for Everyday Spaces

The Saunier Duval SDH17-025 NW VivAir is a wall-mounted air-to-air heat pump designed to bring flexible climate control to homes and small offices. Built for both cooling and heating, it combines straightforward operation with a compact indoor unit, making it a smart choice for users who want comfort without complicated routines.

One of its strongest points is versatility. In AUTO mode, the system adapts to the room temperature and selects cooling or heating as needed. That makes daily use simple, while the COOL, DRY, FAN, and HEAT modes give more control when you want to fine-tune performance. The remote control is central to the experience, offering access to temperature settings, fan speed, airflow direction, timer functions, sleep mode, and turbo operation.

Efficiency is another major advantage. The inverter-driven design helps match power output to demand, which supports lower energy use and smoother operation. The heat pump function also stands out, since it can transfer heat rather than generate it from scratch. For many users, that means a more economical way to stay warm in colder months. The system also uses R-410A refrigerant and includes features such as auto restart, anti-freeze protection, and valve shielding for added practicality.

The VivAir line is clearly built with comfort and maintenance in mind. The anti-dust filter helps reduce circulating particles, while the X-FAN function keeps the indoor unit dry after cooling or dehumidifying, helping limit moisture buildup. Sleep mode adjusts temperature gently overnight, and the timer lets you plan operation around your routine. The result is a unit that feels modern, responsive, and thoughtfully designed.

If you are comparing compact climate solutions and looking for the Saunier Duval SDH17-025 NW VivAir Manual, it is especially useful for understanding setup, remote control functions, cleaning steps, and energy-saving tips. Those details show that this model is not only about cooling and heating, but also about long-term reliability and sensible everyday use.

Notes

  • Best suited for residential and office environments.
  • Regular filter cleaning helps preserve performance.
  • Proper installation and periodic servicing are important for safe operation.
  • Always keep airflow paths clear for the best results.
M: OA-GPT-54-NAN

© Copyright 2026 Manual.ly