Manual.ly Logo

PowerWalker VFI 20000 CPR 3/1 Manual

0.0 · 0 Ratings

PDF manual · 84 Pages

English

M: OA-GPT-54-NAN
page

/ 84

Loading...
bbb4b07170712fa0ff52ac16e35547a7b189 page 23
32
3-9. Fault Code
3-9-1. Fault Code for 10~20000CPR
Fault code
Fault event
Icon
Fault code
Fault event
Icon
01
Bus start failure
None
1A
Negative power fault
None
02
Bus over
None
21
Battery SCR short circuited
None
03
Bus under
None
24
Inverter relay short circuited
None
04
Bus unbalance
None
29
Battery fuse broken in
Battery mode
None
06
Converter over current
None
31
Parallel communication
failure
None
11
Inverter soft start failure
None
36
Parallel output current
unbalance
None
12
High inverter voltage
None
41
Over temperature
None
13
Low inverter voltage
None
43
Overload
14
Inverter output short
circuited
46
Incorrect UPS setting
None
3-10.Warning Indicator
Warning
Icon (flashing)
Alarm
Battery low
Beeping every second
Overload
Beeping twice every second
Battery unconnected
Beeping every second
Over charge
Beeping every second
EPO enable
Beeping every second
Fan failure/Over temperature
Beeping every second
Charger failure
Beeping every second
I/P fuse broken
Beeping every second
Other warnings (Refer to 3-11)
Beeping every second
3-11. Warning Code
Warning code
Warning event
Warning code
Warning event
01
Battery unconnected
10
L1 IP fuse broken
02
IP Neutral loss or IP L2/L3
fuse broken
21
Line situations are different in parallel
system
04
IP phase abnormal
22
Bypass situations are different in
parallel system
05
Bypass phase abnormal
33
Locked in bypass after overload 3
times in 30min
07
Over charge
34
Converter current unbalance
08
Low battery
35
Battery fuse broken
09
Overload
36
Inverter inter-current unbalance

Chat with your PowerWalker VFI 20000 CPR 3/1 manual using AI

Get instant AI answers from your PowerWalker VFI 20000 CPR 3/1 manual

Ask anything about the PowerWalker VFI 20000 CPR 3/1. Answers come from this manual, with the pages they are based on.

VFI 20000 CPR 3/1 Maintenance Schedule

Remind me when maintenance is due
Every 2 months
Recharge battery during storage (40 to 45 C)

Charge the UPS for 1-2 hours every 2 months if stored between 40°C and 45°C.

Show in the manual (page 35)
Every 3 months
Recharge battery during storage (-25 to 40 C)

Charge the UPS for 1-2 hours every 3 months if stored between -25°C and 40°C.

Show in the manual (page 35)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend VFI 20000 CPR 3/1?

Yes No

Frequently Asked Questions

A

It is best for commercial and industrial environments that need reliable power protection for servers, networking gear, control systems, or other mission-critical loads. Its high capacity makes it suitable for demanding setups.

Is this answer helpful?

A

Yes. It includes USB and serial communication support, and the system is designed to work with monitoring software for shutdown configuration, status checks, and better power management.

Is this answer helpful?

A

Yes. The series supports parallel operation when configured as a parallel model. This allows multiple UPS units to work together for higher capacity and improved system flexibility.

Is this answer helpful?

A

It supports AC mode, battery mode, bypass mode, ECO mode, CVCF mode, and battery test operation. These modes help balance protection, efficiency, and power quality.

Is this answer helpful?

A

No. The text strongly indicates that installation and wiring should be performed by qualified personnel. This is a high-power UPS with strict grounding, breaker, and battery requirements.

Is this answer helpful?

A

It includes programmable output terminals so non-critical devices can be separated from critical ones. This helps preserve battery runtime for the most important equipment during outages.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • High-capacity online UPS protection for demanding loads and sensitive equipment.
  • USB/Serial connectivity supports monitoring, shutdown control, and system oversight.
  • Parallel-ready design allows capacity scaling and improved redundancy.
  • LCD interface provides detailed status, alarms, and configuration options.
  • Programmable output helps prioritize critical loads during outages.
VS

Disadvantages

  • Installation is complex and should be done by qualified technicians only.
  • Requires careful wiring, grounding, and breaker setup for safe operation.
  • Heavy, rack-oriented design may be difficult to move or deploy quickly.
  • Backup time depends on battery configuration and load, so runtime varies.
  • Overload or incorrect battery settings can trigger warnings or shutdowns.
M: OA-GPT-54-NAN

Product Specification

Type

Rackmount

Classification

VFI (On-Line)

Apparent Power

20,000 VA

Active Power

18,000 W

Voltage

208/220/230/240 V

Input

Hardwired

Outputs

1x Hardwired

Interfaces

USB, serial

Data Line Protection

N/A

Runtime

12.1 min (50%), 4.2 min (100%)

Charging Time

9 h (90%)

Weight

99.21 lb (Battery Pack: 138.89 lb)

Dimensions (WxHxD)

17.24x10.47x26.30 in (Battery Pack: 17.24x5.24x22.83 in)

Rack Units

6U

19" Rack Depth

26.30 in

Features

LCD, 2x Battery Pack

M: OA-GPT-54-NAN

Product Description

BlueWalker PowerWalker VFI 20000 CPR 3/1, USB/Serial: A Practical High-Capacity Power Backup

BlueWalker PowerWalker VFI 20000 CPR 3/1, USB/Serial is built for environments where stable power is not optional. This online UPS line is designed to protect mission-critical systems with clean, regulated output and fast response when the mains supply becomes unstable. Whether used in IT rooms, industrial setups, or business infrastructure, it focuses on reliability, monitoring, and control.

What makes this series especially appealing is its flexibility. The unit supports single operation or parallel expansion, giving users a path to scale protection as demand grows. It also offers USB and serial communication, so administrators can connect monitoring software and manage shutdown behavior more intelligently. For users who value oversight, the LCD panel and status indicators provide a clear view of operating mode, load, battery state, warnings, and fault codes.

The design emphasizes safety from the very beginning. The instructions stress proper grounding, qualified installation, correct wiring, and careful battery handling. That may sound strict, but it reflects the reality of high-power UPS systems: a well-installed unit can protect equipment, while a poorly installed one can create risk. The PowerWalker VFI 20000 CPR 3/1 is clearly aimed at users who need dependable performance and understand the importance of correct setup.

In daily use, the UPS offers several practical modes, including AC mode, battery mode, bypass mode, ECO mode, and CVCF operation. This gives operators more control over efficiency, protection level, and output behavior. It also supports configurable programmable outputs, which helps separate critical loads from non-critical ones and extend runtime where it matters most.

For larger installations, the parallel function adds another layer of value. Multiple units can work together to increase capacity and resilience, provided each unit is installed and configured properly. Combined with optional monitoring software, the system becomes easier to supervise and integrate into broader power management strategies.

Notes

  • Best suited to commercial and industrial power protection.
  • Installation should be handled by qualified personnel.
  • Battery runtime depends heavily on load and external battery setup.
  • Keep ventilation, grounding, and overload limits in mind for safe operation.
M: OA-GPT-54-NAN

© Copyright 2026 Manual.ly