1. Safety Precautions
This product complies with the requirements of the following European Community Directives:
2014/30/EU (Electromagnetic Compatibility) and 2014/35/EU (Low Voltage) as amended by
2014/32/EU (CE-Marking).
Overvoltage category III 1000V; pollution degree 2.
CAT I: For signal level, telecommunication, electronic with small transient over voltage
CAT II: For local level, appliances, main wall outlets, portable equipment
CAT III: Supplied from a cable under earth; fixed installed switches, automatic cut-off or main plugs
CAT IV: Units and installations, which are supplied overhead lines, which are stand in a risk of
persuade of a lightning, i.e. main-switches on current input, overvoltage-diverter, current
use counter.
To ensure safe operation of the equipment and eliminate the danger of serious injury due to short-
circuits (arcing), the following safety precautions must be observed.
Damages resulting from failure to observe these safety precautions are exempt from any legal claims
whatever.
* Never touch the probe tip while operating insulation test
Do not use this instrument for high-energy industrial installation measurement. This instrument is
intended for use in installation over voltage category III.
* Do not place the equipment on damp or wet surfaces.
* Do not exceed the maximum permissible input ratings (danger of serious injury and/or destruction
of the equipment).
* The meter is designed to withstand the stated max voltages. If it is not possible to exclude without
that impulses, transients, disturbance or for other reasons, these voltages are exceeded a suitable
presale (10:1) must be used.
* Disconnect test leads or probe from the measuring circuit before switching modes or functions.
* To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before
taking any resistance measurements.
* Check test leads and probes for faulty insulation or bare wires before connection to the equipment.
* Please use only 4mm-safety test leads to ensure immaculate function.
* To avoid electric shock, do not operate this product in wet or damp conditions. Conduct measuring
works only in dry clothing and rubber shoes, i. e. on isolating mats.
* Never touch the tips of the test leads or probe.
* Comply with the warning labels and other info on the equipment.
* The measurement instrument is not to be to operated unattended.
* Always start with the highest measuring range when measuring unknown values.
* Do not subject the equipment to direct sunlight or extreme temperatures, humidity or dampness.
* Do not subject the equipment to shocks or strong vibrations.
* Do not operate the equipment near strong magnetic fields (motors, transformers etc.).
* Keep hot soldering irons or guns away from the equipment.
* Allow the equipment to stabilize at room temperature before taking up measurement (important for
exact measurements).
* Do not input values over the maximum range of each measurement to avoid damages of the meter.
* Do not turn the rotary function switch during voltage or current measurement, otherwise the meter
could be damaged.
* Use caution when working with voltages above 35V DC or 25V AC. These Voltages pose shock
hazard.
-9-

Chat with your PeakTech 2695 manual using AI

Get instant AI answers from your PeakTech 2695 manual

Ask anything about the PeakTech 2695. Answers come from this manual, with the pages they are based on.

2695 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the unit

Re-calibration is recommended after one year of operation.

Periodically
Clean the case

Wipe with a damp cloth and mild detergent. Do not use abrasives or solvents.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend 2695?

Yes No

Frequently Asked Questions

A

Remove the battery compartment cover using a screwdriver. Extract the old batteries ensuring correct polarity. Insert six new one point five V AA batteries. Secure the cover and check the display for battery level.

Is this answer helpful?

A

The device complies with safety standards for Category three at 1000 volts. It is suitable for supply from underground cables and fixed switches. Always follow specific safety rules for category four environments.

Is this answer helpful?

A

Resistance checks cover ranges from zero to 4000 megaohms. The open circuit voltage depends on the selected range. Ensure voltage inputs do not exceed maximum limits.

Is this answer helpful?

A

No, the device is intended for indoor use only. Do not place it on wet surfaces or operate in damp conditions. This prevents serious injury or damage to the unit.

Is this answer helpful?

A

Annual calibration is recommended to ensure optimal accuracy. Factory calibration is provided but may drift over time. Follow the manufacturer guidelines for service intervals.

Is this answer helpful?

A

Wipe the case with a damp cloth and mild detergent. Do not use solvents or abrasive materials. Ensure no moisture enters the interior to prevent shorts.

Is this answer helpful?

A

Dispose of old batteries at council collection points. Do not place them in domestic trash. Return used batteries to a local shop for recycling.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • Robust design with overload protection in all measurement ranges.
  • High safety rating compliant with CAT III category standards.
  • Large LCD display with convenient backlight feature.
  • Wide measurement range covering resistance and voltage.
  • Automatic zero adjustment simplifies calibration tasks.
VS

Disadvantages

  • Limited to indoor use only as per specifications.
  • No automatic ranging function requires manual selection.
  • Requires six AA batteries which may impact longevity.
  • Regular annual calibration is recommended for accuracy.
M: qwen/qwen3.5-flash-20260224

Product Description

PeakTech 2695 Insulation Tester

Comprehensive Overview

The PeakTech 2695 Insulation Tester is designed for professionals requiring reliable and precise electrical measurements in various environments. Information often associated with the PeakTech 2695 Insulation Tester Manual highlights its robust industrial features. This device complies with the latest EU directives for low voltage safety and electromagnetic compatibility. It supports category three overvoltage protection specifically rated at one thousand volts. This ensures safety during complex electrical testing scenarios involving high energy.

Measurements extend across multiple electrical domains effectively. Resistance checks cover a vast range from zero to 4000 megaohms. Voltage capabilities include stable readings up to 750 volts AC and 1000 volts DC. Insulation testing utilizes high voltage outputs between 125 and 1000 volts for thorough analysis. The digital display provides clear visual feedback on all parameters. A backlight ensures readability in low light conditions without strain. Data hold functions capture peak and minimum values for later review.

Safety precautions are paramount during daily operation. Avoid touching probes while conducting insulation tests to prevent shock. Ensure the equipment is on a dry surface always. Do not operate in wet conditions to prevent shock hazards completely. The casing is lightweight yet durable plastic construction. It resists shocks and vibrations common in industrial fields. Battery indicators alert users when power is low effectively. Six one point five V cells provide the necessary nine volts DC.

Operational Guidance and Procedures

Operating the instrument requires attention to detail and safety. Disconnect all power to the circuit prior to resistance checks. Select the correct range using the rotary switch mechanism. Test leads must be secured to the V and COM jacks accurately. Push the test button to start the active measurement process. Results update automatically based on high frequency sampling rates. Environmental factors influence results significantly during operation. Humidity lowers insulation values compared to dry air.

Maintenance and Support

Proper maintenance ensures continued performance over many years. Replace batteries immediately upon low power indicators appearing. Store the unit in a dry location away from moisture. Avoid modifying the internal circuits under any circumstances. Only qualified technicians should attempt to open the housing. Annual calibration is recommended for optimal accuracy and reliability. This tool remains a reliable partner for electrical maintenance professionals. It balances power with portability for efficient daily workflows. Accessories include test leads and a carrying case. Cleaning requires a damp cloth without abrasive agents. Additionally, the system warns against exposure to explosive substances. Users must dispose of old batteries at council collection points. This adheres to strict environmental regulations regarding hazardous waste. Do not place the device face down to prevent control damage. Always check cables for damage before use. Temperature stabilization is vital after transport. Ensure batteries are inserted correctly to avoid short circuits.