1. Safety Precautions
This product complies with the requirements of the following European
Community Directives: 2004/108/EC (Electromagnetic Compatibility)
and 2006/95/EC (Low Voltage) as amended by 2004/22/EC (CE-
Marking).
Overvoltage category III 600; pollution degree 2.
CAT I: For signal level, telecommunication, electronic with small
transient over voltage
CAT II: For local level, appliances, main wall outlets, portable
equipment
CAT III: Supplied from a cable under earth; fixed installed switches,
automatic cut-off or main plugs
CAT IV: Units and installations, which are supplied overhead lines,
which are stand in a risk of persuade of a lightning, i.e. main-
switches on current input, overvoltage-diverter, current use
counter.
To ensure safe operation of the equipment and eliminate the danger of
serious injury due to short-circuits (arcing), the following safety
precautions must be observed.
Damages resulting from failure to observe these safety precautions are
exempt from any legal claims whatever.
* Do not use this instrument for high-energy industrial installation
measurement.
* Do not place the equipment on damp or wet surfaces.
* Do not operate the equipment near strong magnetic fields (motors,
transformers etc.).
* Do not exceed the maximum permissible input ratings (danger of
serious injury and/or destruction of the equipment).
* The meter is designed to withstand the stated max voltages. If it is
not possible to exclude without that impulses, transients,
disturbance or for other reasons, these voltages are exceeded a
suitable presale (10:1) must be used.
* Do not operate the meter before the cabinet has been closed and
screwed safely as terminal can carry voltage.
-27-

Chat with your PeakTech 2025 manual using AI

Get instant AI answers from your PeakTech 2025 manual

Ask anything about the PeakTech 2025. Answers come from this manual, with the pages they are based on.

2025 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the device

Recalibration is recommended after one year of use to ensure accuracy.

Show in the manual (page 26)
When battery symbol appears
Replace the battery

Replace 1.5V AAA batteries immediately when the battery symbol appears to avoid false readings.

Show in the manual (page 23)
Periodically
Clean the casing

Wipe the case regularly with a damp cloth and mild detergent; do not use abrasives.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend 2025?

Yes No

Frequently Asked Questions

A

It is suited for electronics troubleshooting, service work, training, and general maintenance. It handles common checks like voltage, current, resistance, continuity, diode testing, capacitance, frequency, and temperature.

Is this answer helpful?

A

Yes. It offers automatic range selection for convenient everyday use, and manual range selection when you want more control over the measurement range.

Is this answer helpful?

A

Yes. With the included temperature probe and adapter, it can measure temperature in both Celsius and Fahrenheit, making it useful for technical and repair tasks.

Is this answer helpful?

A

It is designed with CAT III 600V protection, fused current inputs, and clear safety limits. As always, correct lead placement and safe measurement habits are essential.

Is this answer helpful?

A

Yes. The meter includes a USB interface for PC connection, allowing data to be recorded, analyzed, and displayed with the supplied software.

Is this answer helpful?

A

A battery symbol appears on the display. The batteries should be replaced soon, because low power can cause inaccurate readings and unreliable operation.

Is this answer helpful?

A

Yes. It includes both diode test and continuity check functions, which are useful for identifying open circuits, shorts, and basic semiconductor behavior.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Wide measurement range: voltage, current, resistance, capacitance, frequency, temperature, diode, continuity, and transistor tests.
  • CAT III 600V safety rating with fused inputs helps protect the user and the meter during common electrical tasks.
  • Backlit 6000-count display and bargraph improve readability in bright or low-light environments.
  • USB interface supports PC logging, analysis, and data transfer for longer measurement sessions.
VS

Disadvantages

  • 10A measurements are time-limited, so high-current work requires short duty cycles and careful planning.
  • Temperature, PC-link, and advanced functions may require extra setup with the adapter, software, and cable.
  • Like most multimeters, it needs correct lead placement and range selection to avoid damage or unsafe readings.
M: OA-GPT-54-NAN

Product Description

PeakTech 2025 Digital Multimeter: Compact Power for Everyday Diagnostics

The PeakTech 2025 Digital Multimeter stands out as a practical all-rounder for anyone who needs reliable measurements without a steep learning curve. Built with automatic range selection, a clear 6000-count LCD, and a bright backlight, it makes everyday troubleshooting faster and easier. If you are looking for the PeakTech 2025 Digital Multimeter Manual style of guidance translated into a real-world overview, this model shows why it is popular in education, service work, and home electronics projects.

One of its biggest strengths is versatility. It covers DC and AC voltage, current, resistance, capacitance, frequency, duty cycle, temperature, diode testing, continuity checks, and transistor measurement. That means a single tool can handle everything from checking batteries and power supplies to tracing faults in circuits and testing components. The included USB interface also adds a modern touch, letting users record and analyze readings on a PC.

Safety is clearly a priority. The meter is rated for CAT III 600V, includes protected inputs, and supports warning limits for current measurement. Features such as auto power-off, battery status indication, data hold, and min/max capture make it easier to work efficiently while reducing mistakes. The compact body and fold-out stand also help on a crowded bench or in the field.

For students and technicians, the PeakTech 2025 is especially appealing because it balances functionality with accessibility. Manual range selection is available when precision is needed, while auto-ranging keeps routine measurements simple. The supplied accessories, including test leads, temperature probe, adapter, software, and USB cable, make it ready to use right away.

In short, this is a well-rounded digital multimeter for users who want broad measurement capability, dependable safety features, and PC connectivity in one portable device.

Notes

  • Use the correct input terminal before measuring current.
  • Do not measure resistance or continuity on live circuits.
  • Replace fuses and batteries only with matching parts.
  • Keep the meter dry and store it away from heat and moisture.