Manual.ly Logo

PeakTech 2015 A Manual

0.0 · 0 Ratings

PDF manual · 60 Pages

English

M: QW-35-FL
page

/ 60

Loading...
51153187b40aac943f71719e907275d8b88d page 38
56
7. Care and Maintenance
7.1. Installing the battery
Your meter requires a 9V battery for power. The battery
symbol appears when the battery voltage drops to the
certain limits. For proper operation, replace the battery as
soon as possible. Continued use with a low battery will lead
to abnormal readings.
Warning!
To avoid electric shock, disconnect both test leads from
equipment before you remove or install the battery.
Follow these steps to install the battery:
1. Turn off the power and disconnect the two test leads.
2. Remove the screw to open the battery cover.
3. Remove the battery.
4. Place the battery into the battery compartment.
5. Replace the battery cover and secure it with the screw.
WARNING! Do not operate the meter until you replace the
battery and close the battery compartment cover.
Notes:
Never leave a weak or dead battery in your meter. Even a
leakproof battery can leak damaging chemicals. When you
are not going to use your meter for a week or more, remove
the battery.

Chat with your PeakTech 2015 A manual using AI

Get instant AI answers from your PeakTech 2015 A manual

Ask anything about the PeakTech 2015 A. Answers come from this manual, with the pages they are based on.

2015 A Maintenance Schedule

Remind me when maintenance is due
Yearly
Recalibrate the multimeter

The manufacturer recommends repeating the factory calibration after one year of use.

Show in the manual (page 59)
Before each use
Inspect device and accessories for damage

Check the multimeter and test leads for insulation damage, cracks, or breaks before every measurement. Do not use if damaged.

Show in the manual (page 35)
Regularly
Clean the housing

Wipe the case with a damp cloth and mild cleaning agent. Do not use caustic abrasives.

Show in the manual (page 35)
When low battery symbol appears
Replace the 9V battery

Switch off the device, remove test leads, and replace the battery when the low battery indicator is shown to ensure accuracy.

Show in the manual (page 28)
If unused for a week or more
Remove the battery from the compartment

Take out the battery during long periods of non-use to prevent damage from potential leakage.

Show in the manual (page 56)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 2015 A?

Yes No

Frequently Asked Questions

A

Yes, due to high safety ratings and compliance with European Union directives for low voltage and electromagnetic compatibility it is designed for industrial and professional environments.

Is this answer helpful?

A

True RMS technology ensures accurate readings for non-sinusoidal signals with a precision of plus or minus 1 point 2 percent plus digits for AC voltage ranges.

Is this answer helpful?

A

Up to 10A for limited bursts with proper fuse protection it is rated for max 10 seconds every 15 minutes to prevent fuse failure or device damage.

Is this answer helpful?

A

The symbol on the display alerts the user so they should swap the battery immediately to avoid inaccurate readings or damage to the measurement results.

Is this answer helpful?

A

Yes, with the included thermocouple adapter and sensor it measures from minus 20 to 250 degrees Celsius using the temperature function on the selector switch.

Is this answer helpful?

A

Yes, after 15 minutes of inactivity to save battery power the device automatically enters power off mode to ensure longer battery life during use.

Is this answer helpful?

A

The dimensions are 201 mm length, 101 mm width, 68 mm depth with a weight of 483 grams including the battery for compact storage.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True RMS AC measurement for accurate non-sinusoidal waveforms in industrial settings.
  • High safety rating with CAT III 1000V and CAT IV 600V compliance for electrical work.
  • Versatile measurement range includes temperature, frequency, capacitance, and diode testing.
  • Clear backlight LCD display with bar graph trend indicator for easy reading.
  • Auto range function reduces user error during complex electrical diagnostics operations.
VS

Disadvantages

  • Manual battery replacement requires opening the rear service flap for access.
  • High current limit restricts continuous measurements to 10 seconds every 15 minutes.
  • Test leads resistance can impact accuracy on low resistance measurements under 400 ohms.
  • Battery powered operation requires spare 9V cells for extended field work sessions.
  • Accuracy specifications vary with ambient temperature deviations from 23 degrees Celsius.
M: QW-35-FL

Product Specification

Measurement Range

max. 10A, max. 1,000V, max. 40MOhm

Scope of Delivery

Bag, Test Leads, Battery

M: QW-35-FL

Product Description

Exploring the PeakTech P 2015 A TrueRMS Digital Multimeter

When electrical professionals search for the PeakTech P 2015 A TrueRMS Digital Multimeter Manual, they are often looking for reliable specifications and performance details. This robust instrument stands out in the industry for its versatility and durability. It features a clear 3 3/4 digit LCD display with 3999 counts. Reading measurements is effortless even in low light thanks to the backlight. The device handles a wide range of electrical tasks including DCV, ACV, DCA, ACA, resistance, and capacitance. It serves as an essential tool for anyone working with electronics.

Safety and Compliance

Safety is paramount when working with electrical systems. This multimeter adheres to CAT III 1000V and CAT IV 600V standards. It meets European Union directives for electromagnetic compatibility and low voltage. Users can trust the double insulated housing. Overload prevention prevents damage to the internal circuit. Working with dangerous voltages requires caution, and this tool provides the necessary safeguards against short circuits and arc flashes.

Measurement Capabilities

Beyond basic voltage checks, this unit measures temperature using a thermocouple. The range spans from minus 20 to 250 degrees C with high precision. Frequency and duty cycle measurements are also available up to 1 MHz. True RMS technology ensures accurate readings for non sinusoidal signals. The bar graph provides a visual trend indicator for fluctuating data. Minimum and maximum value functions help capture transient signals without constant monitoring by the operator.

Usability and Maintenance

The unit includes a rotary selector switch for intuitive operation. Automatic range selection simplifies usage for hobbyists and professionals alike. A 10 A input allows for high current measurements up to 10 seconds. The battery compartment is accessible via a service flap on the back. Cleaning is simple with a damp cloth. Always ensure the device is closed before powering on. It is designed for stability and ease of use in varied environments.

Conclusion and Specifications

These features make it a staple in workshops globally. Whether for home repair or industrial maintenance, accuracy and safety remain the top priorities. The included accessories cover most basic needs right out of the box. The 9V battery powers the unit for extended periods. Users appreciate the clear display and logical layout of the function keys. Dimensions are compact at 201 mm long. It weighs roughly 483 grams including battery. The stand is useful on workbenches. The fuses are accessible through the rear cover. This ensures long term reliability. It is essential for technicians to follow the safety precautions during installation.

Notes on Usage

Regular calibration is recommended to maintain accuracy over time. Always inspect test leads for damage before starting work. Do not exceed the maximum voltage limits stated in safety guidelines. Keep the device dry to prevent corrosion of internal components.

M: QW-35-FL

© Copyright 2026 Manual.ly