d1fad8b15b496e0012d809137658e399c27d page 26
The display value is the test lead resistance to be
subtracted.
7. After completing measurement, disconnect the test leads.
6.5. Continuity testing
1. Select the
°
))) position by turning the rotary selector switch.
2. Follow step 2 and 4 as for resistance measurements.
3. An audible tone will sound for resistance less than approx.
100 . After all measurements are completed, disconnect
the test leads from the circuit and from the input terminals.
6.6. Diode testing
CAUTION!
Measurements must only be made with the circuit power
OFF.
1. Set the rotary selector switch to the - position.
2. Follow steps 2 and 4 as for resistance measurements.
3. The red test lead should be connected to the anode and the
black lead to the cathode. For a silicon diode, the typical
forward voltage should be about 0,7 V or 0.4 V for a
germanium diode.
4. If the diode is reverse biased or there is an open circuit the
display shows “OL”.
6.7. Frequency measurements
1. Set the rotary selector switch to the Hz% position.
2. Plug the black and red test leads into the COM and Hz input
terminals respectively.
-37-

Chat with your PeakTech 1640 manual using AI

Get instant AI answers from your PeakTech 1640 manual

Ask anything about the PeakTech 1640. Answers come from this manual, with the pages they are based on.

1640 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the meter

The manufacturer recommends recalibrating the unit after 1 year to ensure measurement accuracy.

Show in the manual (page 41)
As needed
Replace the battery

Replace the 9V battery as soon as the battery symbol appears on the display to avoid inaccurate readings.

Show in the manual (page 38)
Periodically
Clean the housing

Wipe the cabinet with a dry clean cloth or damp cloth and mild detergent. Do not use solvents or abrasives.

Show in the manual (page 40)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 1640?

Yes No

Frequently Asked Questions

A

The device can measure alternating and direct currents up to 1000 Amperes. It uses transformer jaws to capture the magnetic field around the conductor, allowing for non-intrusive measurements.

Is this answer helpful?

A

No, the PeakTech 1640 is designed exclusively for indoor applications. Exposure to weather elements like rain or extreme humidity can damage the internal components and void safety certifications.

Is this answer helpful?

A

Turn off the device and remove test leads. Unscrew the battery compartment cover on the rear, remove the old 9V battery, insert a new NEDA 1604 equivalent, and secure the cover back in place.

Is this answer helpful?

A

No, the manual explicitly states not to use this instrument for high-energy industrial installation measurements. It is intended for general electrical testing within its specified voltage limits.

Is this answer helpful?

A

The ZERO button is used specifically for DC current measurements. Pressing it calibrates the display to zero before taking a reading to eliminate any offset errors caused by magnetic interference.

Is this answer helpful?

A

Yes, the device features an automatic shutdown after 35 minutes of inactivity to preserve battery life. This ensures the meter is ready for use while preventing unnecessary drain.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High accuracy with 3 ¾-digit resolution for detailed readings
  • Measures up to 1000 A AC/DC current without breaking the circuit
  • Complies with strict EU safety standards for professional use
  • Includes auto-ranging function to simplify operation
  • Compact and lightweight design for easy portability
VS

Disadvantages

  • Maximum voltage limit of 600 V restricts high-voltage applications
  • Requires careful handling to avoid damage from strong magnetic fields
  • Battery life depends on usage frequency and requires regular replacement
  • Manual range switching may be less convenient than full auto-ranging
  • Not suitable for outdoor use due to indoor-only rating
M: QW-35-FL

Product Specification

Measurement Range

max. 1000A, max. 600V, max. 40MΩ

Package Contents

Case, test leads

M: QW-35-FL

Product Description

PeakTech 1640 Clamp Meter Multimeter Review

The PeakTech 1640 Clamp Meter Multimeter is a robust digital tool designed for professionals and hobbyists who require precise electrical measurements in various environments. This device combines the functionality of a standard multimeter with the convenience of a clamp meter, allowing users to measure current without breaking the circuit. It features a clear 3 ¾-digit LCD display that provides readings up to 4000 counts, ensuring high visibility even in dimly lit workspaces.

One of the standout features of this instrument is its ability to handle both AC and DC measurements across a wide range of parameters. Users can measure voltage up to 600 V, current up to 1000 A, resistance, frequency, and duty cycle. The built-in transformer jaws are capable of clamping around conductors with diameters up to 30 mm, making it versatile for different wire sizes. The device also includes power measurement capabilities, supporting wattage calculations for both AC and DC circuits with high accuracy.

Safety is paramount with the PeakTech 1640. It complies with EU directives for electromagnetic compatibility and low voltage equipment. The tool is rated for Overvoltage Category III at 600V, suitable for distribution level installations. It includes essential safety features like overload protection and automatic range selection to prevent user error. The unit operates within a temperature range of -10°C to 50°C and is powered by a standard 9V battery, which is easily replaceable.

The meter comes complete with test leads, a carrying case, and an instruction manual. Its compact design and lightweight construction make it portable for field work. Whether you are troubleshooting industrial machinery or performing residential electrical checks, this multimeter offers reliability and precision. Remember to always follow safety guidelines, such as wearing dry clothing and using insulated mats, to ensure safe operation.

Key Notes

  • Ensure the device is fully closed before operation.
  • Always start with the highest range for unknown values.
  • Replace batteries immediately when the low battery symbol appears.
M: QW-35-FL