d0ba131ceaa36955f7e6956cc2297aa45b59 page c
12 ProMax Rain 4000
Translation of the original Operating
Instructions
WARNING
• This unit can be used by chil-
dren aged 8  and above and
by persons with reduced
physical, sensory or mental
capabilities or lack of experi-
ence and knowledge if they
are supervised or have been
instructed on how to use the
unit in a safe way and they un-
derstand the hazards in-
volved.
• Do not allow children to play
with the unit.
• Only allow children to carry
out cleaning and user mainte-
nance under supervision.
• Ensure that the unit is fused
for a rated fault current of
max. 30 mA by means of a
fault current protection de-
vice.
• Only connect the unit if the
electrical data of the unit and
the power supply correspond.
The unit data is to be found on
the unit type plate, on the
packaging or in this manual.
• Possible death or severe in-
jury from electrocution! Be-
fore reaching into the water,
always disconnect all units in
the water that have a voltage
of >12 V AC or >30 V DC
from the power supply.
• Only operate the unit if no per-
sons are in the water.
• A damaged connection cable
cannot be replaced. Dispose
of the unit.
SAFETY INFORMATION
Electrical connection
• Extension cables and power distributors
(e.g. outlet strips) must be suitable for
outdoor use (splash-proof).
• Protect the plug connection from mois-
ture.
• Only connect the unit to a correctly fitted
socket.
Safe operation
• Never operate the unit if the housing is
defective!
• Never operate the unit if an electrical ca-
ble is defective!
• Never carry or pull the unit by the elec-
trical cable.
• Route cables such that they are pro-
tected from damage and do not present
a tripping hazard.
• Never carry out technical changes to the
unit.
• Only carry out work on the unit that is
described in this manual. If problems
cannot be overcome, please contact an
authorised customer service point or, if
in doubt, the manufacturer.
• Only use original spare parts and acces-
sories for the unit.
• Disconnect the unit from the power sup-
ply during thunderstorms.

Chat with your Oase ProMax Rain 4000 manual using AI

Get instant AI answers from your Oase ProMax Rain 4000 manual

Ask anything about the Oase ProMax Rain 4000. Answers come from this manual, with the pages they are based on.

ProMax Rain 4000 Maintenance Schedule

Remind me when maintenance is due
Monthly
Clean the filter screen

Turn filter screen clockwise to remove and clean under clear water. Reassemble in reverse order.

Show in the manual (page 10)
Semiannual
Clean the pump unit

Clean unit at least twice a year using non-aggressive cleaners. Rinse all parts thoroughly with clear water.

Before winter/frost
Store and protect from frost

Drain unit and hoses, clean thoroughly, check for damage, and store in a dry, frost-free place.

Show in the manual (page 10)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend ProMax Rain 4000?

Yes No

Frequently Asked Questions

A

No, this pump is not suitable for drinking water. It is designed exclusively for clear water, rainwater, and transferring water from basins or wells for irrigation purposes only.

Is this answer helpful?

A

The maximum head height for the Oase ProMax Rain 4000 is 12 meters, allowing it to push water to significant heights for garden irrigation systems.

Is this answer helpful?

A

To switch to manual mode, move the handle to a horizontal position and press the cable directly against the float switch so it stands vertically. This keeps the pump running constantly.

Is this answer helpful?

A

No, the pump is not frost-proof. You must drain it completely and store it in a dry, frost-free location before winter temperatures arrive to prevent damage.

Is this answer helpful?

A

No, the power connection cable cannot be replaced. If the cable is damaged, the entire unit must be disposed of and replaced to ensure electrical safety.

Is this answer helpful?

A

You should clean the filter screen at least once a month, or more frequently if you notice reduced performance or heavy sediment in the water source.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High flow rate of 4000 l/h for efficient water movement
  • Automatic float switch prevents overfilling and saves energy
  • Includes comprehensive connection set for easy setup
  • Handles small particles up to 0.3 mm without clogging easily
  • Adjustable handle allows for flexible manual operation modes
VS

Disadvantages

  • Not suitable for long-term continuous recirculation in ponds
  • Cannot be used for drinking water or saltwater applications
  • Connection cable cannot be replaced if damaged
  • Requires specific storage during freezing temperatures
  • Impeller replacement must be done by authorized service only
M: QW-35-FL

Product Specification

Power

370W

Flow rate

1056.7gph

Head height

39.37in

Submersion depth

22.97in

Pressure

17.4psi

Pressure connection

1"

Features

without tank

Cable length

32.81ft

Weight

28.22lbs

M: QW-35-FL

Product Description

Oase ProMax Rain 4000: The Ultimate Rain Barrel Pump

The Oase ProMax Rain 4000 Electric Rain Barrel Pump is a robust and reliable solution for managing water resources in your garden. Designed primarily for rain barrels, cisterns, and wells, this pump ensures efficient irrigation and watering with minimal effort. Whether you are looking to empty a large water butt or transfer clear water between containers, the ProMax Rain 4000 delivers consistent performance.

This pump features an automatic float switch that activates when the water level rises and deactivates as it drops, preventing dry running in most scenarios. For manual control, the adjustable handle allows you to lock the float switch vertically, keeping the pump running continuously for tasks like draining deep tanks. Safety is paramount; the unit includes a kink protection system for the pressure hose and requires connection to a residual current device for user safety.

Constructed with durability in mind, the pump handles water with particles up to 0.3 mm, making it ideal for slightly dirty rainwater. It boasts a maximum flow rate of 4000 liters per hour and can lift water up to 12 meters. The included connection set simplifies installation, featuring quick-release couplings and various adapters for hoses and taps. Always remember to store the unit indoors during winter as it is not frost-proof.

Key Features

  • Automatic Operation: Float switch manages on/off cycles based on water levels.
  • High Capacity: Delivers up to 4000 liters per hour for rapid drainage.
  • Versatile Use: Suitable for rain barrels, cisterns, wells, and basins.
  • Safety First: Requires RCD protection and has a non-replaceable damaged cable policy.

Important Notes

  • Do not use for drinking water or saltwater.
  • Clean the filter screen at least once a month.
  • Disconnect power before any maintenance work.