Preparation
Spraying
1. Place the device on its back. (Fig. 8)
2. Using the pump lever [11], pump slowly and regularly to maintain a continuous spraying
pressure. (→ Table 2, Fig. 8)
+
Max. pressure should not exceed 6 bar. If the maximum pressure is exceeded, the
pressure relief valve will actuate and release the excess pressure from the pressure
vessel.
1. Screw the cover [19] o󰀨 the tank. (Fig. 6)
+
Measuring cups [20] are integrated in the cover [19] and can be used to prepare the
spraying agent. Fill the tank 1/3 with water, pour in the spraying agent and then ll up
with water.
2. Pour the spray liquid through the lling strainer [21] into the tank. (Fig. 7)
+
In the case of 18 liter devices the maximum lling quantity is reached as soon as the
liquid level can be seen in the lling strainer.
3. Screw the cover [19] onto the tank. (Fig. 6)
Table 2. Dependence: Spraying rate – spraying pressure
Nozzle
Pressure
1.1 (Basic equipment) 80015 8002
Flow rate in l/min
2.0 bar 0.56 0.48 0.65
6.0 bar 0.96 0.85 1.13
3. Ensure that the optimum spraying pressure is set on the pressure gauge [22] (Figs. 8
and 9).
GB IRL AUS USA NZ CDN IND
+
To prevent dripping, hold the spray wand up when rst spraying and activate the
shut-o valve until no more liquid mixed with air comes out of the nozzle.
Observe the instructions in the section entitled “Safety”.
Operate the device only while it is vertical or suspended upright and nearly vertical.
Avoid allowing drops of spray to drift onto areas that are not being treated.
Observe the instructions of the spray product manufacturer!
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
Observe the instructions in the section entitled „Safety“.
The device must be in an upright position.
If lling the tank from a water line, ensure that the line or a hose does not project
into the tank.
+
If liquid mixed with air emerges from the nozzle, the tank is empty.
Pump the device completely empty after each fth lling at the latest.
7393400_0618_ RS12_-RS18_16spr.indd 17 08.06.2018 11:04:55

Chat with your Mesto RS125 3552 manual using AI

Get instant AI answers from your Mesto RS125 3552 manual

Ask anything about the Mesto RS125 3552. Answers come from this manual, with the pages they are based on.

RS125 3552 Maintenance Schedule

Remind me when maintenance is due
Every 2 years
External inspection by expert

Unless local laws specify otherwise, have an expert perform an external test of the device every 2 years.

Show in the manual (page 18)
Every 5 years
Internal inspection by expert

Unless local laws specify otherwise, have an expert perform an internal test of the device every 5 years.

Show in the manual (page 18)
After every use
Rinse tank and wipe device

Activate shut-off valve to depressurize. Dilute remaining liquid twice with 0.5L water each time and spray. Wipe device with a moist cloth.

Show in the manual (page 18)
Every 5 fillings
Pump device completely empty

To prevent the pressure vessel from filling with liquid, pump the device completely empty at least after every fifth filling.

Show in the manual (page 17)
Every 50 uses or Yearly
Grease diaphragm

Perform this maintenance after 50 uses, upon malfunction, or at least once a year (preferably after winter). Grease the diaphragm [24].

Show in the manual (page 18)
Every 50 uses or Yearly
Oil pump rod

Perform this maintenance after 50 uses, upon malfunction, or at least once a year. Oil the pump rod [33].

Show in the manual (page 18)
Every 50 uses or Yearly
Grease shaft bearings

Perform this maintenance after 50 uses, upon malfunction, or at least once a year. Grease the bearing points on the shaft [16].

Show in the manual (page 18)
Every 50 uses or Yearly
Clean nozzle and insert

Perform this maintenance after 50 uses, upon malfunction, or at least once a year. Clean the nozzle [41] and insert [40] under running water, using a brush if necessary.

Show in the manual (page 18)
Every 50 uses or Yearly
Clean filter

Perform this maintenance after 50 uses, upon malfunction, or at least once a year. Clean the filter [38] under running water.

Show in the manual (page 18)
Every 10 years
Strength test by expert

Unless local laws specify otherwise, have an expert perform a strength test of the device every 10 years.

Show in the manual (page 18)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend RS125 3552?

Yes No

Frequently Asked Questions

A

You can use plant protection products, cleaning agents, and disinfectants approved for sprayers. Avoid flammable liquids, corrosive acids above 10%, and ammonia-based fluids.

Is this answer helpful?

A

Hold the spray wand upward during the first spray and operate the shut-off valve until no air-mixed liquid comes out. Ensure the nozzle insert is clean and properly seated.

Is this answer helpful?

A

No, never leave liquid in the device. Always drain and rinse the tank after use to prevent corrosion and damage to seals.

Is this answer helpful?

A

The device must not be exposed to temperatures above 40 degrees Celsius. Do not leave it in direct sunlight or near heat sources.

Is this answer helpful?

A

Perform basic maintenance after every 50 uses or at least once a year. Grease the diaphragm, oil the pump rod, and clean the filter regularly.

Is this answer helpful?

A

No, the warranty covers material and processing errors but excludes wearing parts like O-rings, diaphragms, and seals damaged by normal use.

Is this answer helpful?

A

Check if the diaphragm is defective or if foreign objects are blocking the valves. Clean the intake and pressure valves or replace the diaphragm if necessary.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Durable polypropylene tank resistant to corrosion
  • Ergonomic design with comfortable back cushion
  • Adjustable pump handle for left or right-handed use
  • Maximum pressure of 6 bar ensures efficient spraying
  • Clear troubleshooting guide included in manual
VS

Disadvantages

  • Not suitable for viscous liquids like paints or fats
  • Requires manual pumping which can be tiring over time
  • Cannot be used with liquids above 40 degrees Celsius
  • Residual quantity remains in the tank after emptying
  • Regular maintenance required to prevent leaks
M: QW-35-FL

Product Specification

Tank Volume

3.17 gal

Operating Pressure

86.96 psi

Hose Length

4.92 ft

Features

Shoulder Strap

Nozzle

Fog Nozzle

M: QW-35-FL

Product Description

The Mesto 3552 RS125 Back Sprayer Manual: A Comprehensive Guide for Efficient Gardening

The Mesto 3552 RS125 Back Sprayer Manual serves as an essential companion for anyone looking to maintain a pristine garden or manage agricultural tasks with precision. This manual is not just a collection of instructions; it is a roadmap to mastering the operation, safety, and maintenance of one of the most reliable sprayers in the market. Designed by Mesto Spritzenfabrik Ernst Stockburger GmbH, the RS125 model stands out for its durability and user-friendly design, making it ideal for applying plant protection products, cleaning agents, and disinfectants.

Understanding the Device

The RS125 is built with a polypropylene tank that holds up to 12 liters of liquid. Its lightweight construction ensures comfort during extended use, while the ergonomic carrying straps and back cushion provide support. The device operates at a maximum pressure of 6 bar, ensuring a fine mist for effective coverage without waste. Safety is paramount, with specific warnings against using the sprayer with flammable liquids, corrosive substances beyond recommended concentrations, or liquids exceeding 40 degrees Celsius.

Assembly and Operation

Setting up the sprayer is straightforward. The manual guides users through attaching the carrying strap, securing the pump lever, and connecting the hose and spray wand. A key feature is the adjustable pump handle, which can be mounted on either side to suit the user's preference. Once assembled, the device requires careful filling. Users should fill the tank one-third with water, add the chemical agent, and then top up with water to prevent splashing and ensure proper mixing.

Maintenance and Care

Longevity depends on proper care. The manual emphasizes regular maintenance, such as greasing the diaphragm and oiling the pump rod after every 50 uses or at least once a year. Cleaning the nozzle and filter after each use prevents clogging and ensures consistent spray patterns. Storing the device with the cap removed in a dry, frost-free environment helps preserve its integrity.

Troubleshooting

Common issues like lack of pressure or dripping nozzles are addressed with clear troubleshooting steps. Whether replacing a defective valve disc or lubricating moving parts, the guide empowers users to resolve problems quickly, minimizing downtime.

Important Notes

  • Always wear protective gear when handling chemicals.
  • Never leave liquid in the tank overnight.
  • Use only original Mesto spare parts for repairs.
M: QW-35-FL

© Copyright 2026 Manual.ly