- ZZUSB02 -
Technische Daten
Technical Data
SCN-USBR.02 SCN-IP000.02 SCN-IP100.02
Schnittstelle
Interface
USB Ethernet Ethernet
Spezikation KNX Schnittstelle
Specication KNX interface
TP-256 mit Long Frame Unterstützung für ETS5/6
TP-256 with long frame support for ETS5/6
Verfügbare Produktdatenbanken
Available application software
ETS 3/4/5/6 ETS 4/5 ETS 4/5
Max. Kabelquerschnitt
Permitted wire gauge
Schraubklemme
Screw terminal
0,5 - 4,0mm² eindrähtig/solid core
0,5 - 4,0mm² feindrähtig/nely stranded
KNX Busklemme
KNX busconnection terminal
0,8mm Ø, Massivleiter/solid core
Versorgungsspannung
Power Supply
KNX bus KNX bus KNX bus
Leistungsaufnahme typ.
Power Consumption
<0,3W <0,8W <0,8W
Umgebungstemperatur
Operation temperature range
0 bis + 45°C 0 bis + 45°C 0 bis + 45°C
Schutzart
Enclosure
IP 20 IP 20 IP 20
Abmessungen
Design
2TE 2TE 2TE
Technische Daten USB Interface, IP Interface/Router
Technical Data USB Interface, IP Interface/Router
1
SCN-USBR.02
Allgemeine Sicherheitshinweise - Important safety notes
Lebensgefahr durch elektrischen Strom - Danger High Voltage
• Das Gerät darf nur von Elektrofachkräften montiert und angeschlossen werden. Beachten sie die länderspezischen
Vorschriften sowie die gültigen KNX-Richtlinien. Die Geräte sind für den Betrieb in der EU zugelassen und tragen das CE
Zeichen. Die Verwendung in den USA und Kanada ist nicht gestattet.
Installation and commissioning of the device only be carried out by authorised electricans. The relevant standards,
directives, regulations and instructions must be observed. The devices are approved for use in the EU and have the CE
mark. Use in USA and Canada is prohibited.
Anschlussklemmen, Bedien- und Anzeigeelemente USB Interface, IP Interface/Router
Terminals, Operating and Display USB Interface, IP Interface/Router
Betriebsanleitung USB Interface, IP Interface/Router
nur für autorisiertes Elektrofachpersonal
Operating Instructions USB Interface, IP Interface/Router
for authorised electricans
1 - Busanschlussklemme
- KNX busconnection terminal
2 - Programmiertaster
- Programming key
3 - Rote Programmier LED
- Red programming LED
4 - LED Anzeigen
- LED indicators
4
SCN-IPx00.02
1
4
5 - Ethernet Schnittstelle
- Ethernet interface
5
Anzeigeelemente IP Interface/Router - Display IP Interface/Router
LED Bus State IP grün an: LAN ok aus: LAN Fehler
LED Bus State IP rot an: manuelles Überschreiben aktiv
LED Bus State TP grün an: KNX Linie ok aus: KNX Linie nicht angeschlossen
LED Trafc IP grün blinkend: Busverkehr auf LAN aus: kein Busverkehr auf LAN
LED Trafc TP grün blinkend: Busverkehr auf KNX Linie aus: kein Busverkehr auf KNX Linie
LED Trafc TP rot blinkend: Übertragungsfehler auf KNX Linie
LED Group Address Telegrammweiterleitung:
aus: LAN- und KNX Linie unterschiedlich grün: Filtertabelle aktiv grün+rot: Alles weiterleiten rot: Sperren
LED Physical Address Weiterleitung Physikalische Adressen:
aus: LAN- und KNX Linie unterschiedlich grün: Filtertabelle aktiv grün+gelb: Alles weiterleiten gelb: Sperren
LED Bus State IP green on: LAN ok off: LAN error
LED Bus State IP red on: manual overwrite active
LED Bus State TP green on: KNX line ok off: KNX line error or not connected
LED Trafc IP green blinking: bus trafc on LAN off: no trafc on LAN
LED Trafc TP green blinking: bus trafc on KNX line off: no trafc on KNX line
LED Trafc TP red blinking: transmission error on KNX line
LED Group Address routing of telegrams:
off: LAN- and KNX line different green: lter table active green+red: route all red: block
LED Physical Address routing of physical addresses:
off: LAN- and KNX line different green: lter table active green+yellow: route all yellow: block
2
®

Chat with your MDT USB Interface manual using AI

Get instant AI answers from your MDT USB Interface manual

Ask anything about the MDT USB Interface. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend USB Interface?

Yes No

Frequently Asked Questions

A

It enables bidirectional communication between a personal computer and the KNX bus. It allows for bus programming and configuration using ETS software. Both USB and Ethernet options exist for connecting to the system.

Is this answer helpful?

A

No, the devices are approved for use in the EU only. Use in the USA and Canada is prohibited according to the manufacturer's safety guidelines and regulatory standards.

Is this answer helpful?

A

No, the interface receives its power supply directly from the KNX bus. This eliminates the need for additional external power sources in most standard installation scenarios.

Is this answer helpful?

A

The module supports ETS versions 3, 4, 5, and 6. It specifically features long frame support for ETS5 and ensures compatibility with modern programming applications.

Is this answer helpful?

A

LED indicators show the status of the bus state and traffic. Green lights indicate ok conditions while red lights signal errors or manual overwrites. Blinking lights show active data traffic.

Is this answer helpful?

A

You can find the product database at the official website www.mdt.de/Downloads.html. It is recommended to download application software before commissioning.

Is this answer helpful?

A

No. The device must be installed by authorized electricians. You must observe relevant standards and directives. High voltage danger exists during connection.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Galvanic isolation protects PC from KNX bus electrical hazards
  • Direct power supply from KNX bus eliminates external adapters
  • Supports long frame requirements for ETS5 and ETS6 software
  • Enables multiple simultaneous connections for improved workflow
  • Modular design allows installation on standard DIN 35mm rails
VS

Disadvantages

  • Use in USA and Canada is prohibited by certification standards
  • Installation must be performed by authorized electricians only
  • Limited to dry indoor room environments only
  • Relies on KNX bus for power which may cause issues if bus fails
  • Initial programming requires downloading external application software first
M: QW-35-FL

Product Specification

Type

Function Module

Protocols

KNX, USB

Function

Interface Expansion

Features

IP20

M: QW-35-FL

Product Description

Unlocking Potential in Building Automation Through the MDT KNX USB Interface 2TE REG Function Module Manual

Smart building automation relies heavily on robust communication standards within the industry. The KNX protocol stands out as a leading choice for professionals seeking true interoperability across various electronic control devices. At the heart of efficient system integration lies the necessity for precise tools to connect personal computers directly with the KNX bus network. This is where the specialized interface units shine brightest within current architectural designs. They facilitate seamless bidirectional communication ensuring superior configuration and monitoring capabilities for increasingly complex installations worldwide.

The comprehensive documentation known as the MDT KNX USB Interface 2TE REG Function Module Manual provides essential guidance for users aiming to master these critical components. Whether you are deploying a simple direct USB connection or an advanced Ethernet router system, understanding the detailed setup process is paramount. The device incorporates galvanic isolation which protects sensitive computing hardware from potential electrical hazards on the KNX line. This safety feature is crucial during installation phases involving dangerous voltage risks encountered on site. Technicians can easily mount the module onto standard DIN 35mm rails located within dry indoor environments.

Detailed technical specifications highlight versatility across different operational modes. The unit accommodates long frame support specifically designed for ETS5 and ETS6 software suites. This ensures compatibility with the latest programming applications required for contemporary automated systems. Power supply is derived directly from the KNX bus eliminating the need for external adapters. Multiple connections allow simultaneous access enhancing overall workflow efficiency during large scale deployment projects involving multiple zones.

Important Installation and Safety Notes

Maintaining safety remains the top priority when handling sensitive electrical equipment. Only qualified electricians should perform professional mounting and commissioning tasks according to regional regulations and national standards. The CE mark confirms compliance within the EU market though usage rights might be restricted elsewhere depending on local laws. LED indicator systems offer immediate visual feedback regarding live bus status and transmission errors allowing for rapid troubleshooting. Monitoring traffic flow between LAN and KNX lines becomes intuitive through distinct color coded lighting systems.

Downloading necessary application software prior to commisioning is highly recommended to ensure smooth parameter assignment. Programming involves assigning physical addresses via ETS followed by uploading the full configuration file into memory. Completion signals are indicated clearly through programmed LED behavior changes turning off once done. These interfaces serve as fundamental bridges between digital planning tools and physical infrastructure elements in smart buildings. Integrating them correctly guarantees optimal performance throughout the entire lifespan of the automation system deployed onsite.

IP routers also support encrypted transmission and time server functions for better synchronization.

M: QW-35-FL

© Copyright 2026 Manual.ly