M: QW-35-FL
page

/ 2

Loading...
abdd1c1a50b1b1200643bba6df736340f5f3 page 1
MDT technologies GmbH
•
51766 Engelskirchen
•
Papiermühle 1
Tel.: + 49 - 2263 - 880
•
Fax: + 49 - 2263 - 4588
•
•
www.mdt.de
Stand: 0322
Technische Änderungen und Irrtümer vorbehalten,
Abbildungen können abweichen.
Technische Daten
Technical Data
STV-160.02 STV-320.02 STV-640.02
Spannung
Voltage
Versorgungsspannung
Mains voltage
230VAC/50Hz 230VAC/50Hz 230VAC/50Hz
Ausgangsspannung
Output voltage
30VDC SELV 30VDC SELV 30VDC SELV
Ausgangsspannung unverdrosselt
Choke free output voltage
-- -- 30VDC SELV
Strom
Current
Nennstrom
Nominal current
160mA 320mA 640mA
Dauerstrom
Continuous current
240mA 480mA 960mA
Spitzenstrom
Peak current
320mA 640mA 1200mA
Max. Summenstrom beider Ausgänge
Max. total current of both outputs
-- -- 1000mA
Wirkungsgrad bei Nennlast typ.*
Efciency at nominal load typ.*
> 82% > 85%
> 87%
Verlustleistung im Leerlauf typ.
Power loss no operation typ.
< 0,45W < 0,45W
< 0,75W
Überspannungskategorie
Overvoltage catagory
III III
III
Max. Kabelquerschnitt
Permitted wire gauge
Schraubklemmen (max. 0,5Nm Anzugsmoment)
Screw terminal (max. 0,5Nm tightening torque)
0,5 - 4,0mm² solid core
0,5 - 2,5mm² nely stranded
0,5 - 4,0mm² solid core
0,5 - 2,5mm² nely stranded
0,5 - 4,0mm² solid core
0,5 - 2,5mm² nely stranded
KNX Busklemme
KNX busconnection terminal
0,8mm Ø, solid core 0,8mm Ø, solid core 0,8mm Ø, solid core
Umgebungstemperatur
Operation temperature range
0 bis + 45°C 0 bis + 45°C 0 bis + 45°C
Schutzart
Enclosure
IP 20 IP 20 IP 20
Abmessungen REG (Teilungseinheiten)
Dimensions MDRC (Space Units)
2TE 2TE 4TE
Technische Daten Spannungsversorgung STV - Technical Data Power Supply
1
1
2
2
3
3
4
4
7
5
5
6
STV-160.02 / STV-320.02 STV-640.02
6
Betriebsanleitung Spannungsversorgung STV - nur für autorisiertes Elektrofachpersonal
Operating Instructions Power Supply STV - for authorised electricans
Allgemeine Sicherheitshinweise - Important safety notes Lebensgefahr durch elektrischen Strom - Danger High Voltage
• Das Gerät darf nur von Elektrofachkräften montiert und angeschlossen werden. Beachten sie die länderspezischen
Vorschriften sowie die gültigen KNX-Richtlinien. Die Geräte sind für den Betrieb in der EU zugelassen und tragen das CE
Zeichen. Die Verwendung in den USA und Kanada ist nicht gestattet.
Installation and commissioning of the device only be carried out by authorised electricans. The relevant standards,
directives, regulations and instructions must be observed. The devices are approved for use in the EU and have the CE
mark. Use in USA and Canada is prohibited.
• Nach dem Einbau des Gerätes und Zuschalten der Netzspannung liegt an den Ausgängen Spannung an.
After Installation and connecting mains power supply the outputs are alive.
• Vor Arbeitsbeginn am Gerät immer über die vorgeschalteten Sicherungen spannungsfrei schalten.
Disconnect the mains power supply prior to installation or disassembly.
• Alle spannungsführenden Klemmen und Anschlüsse müssen nach der Installation vollständig durch die Schalttafel-
abdeckung berührungssicher verschlossen werden. Die Schalttafelabdeckung darf nicht ohne Werkzeug zu öffnen sein.
All screw terminals and connections under current must be covered completely against touching by the switch panel.
It should not be possible to open the switch panel cover without using tools.
Anschlussklemmen und Anzeigeelemente Spannungsversorgung STV
Terminals and Display Power Supply STV
1 - Busanschlussklemme
- KNX busconnection terminal
2 - Resettaster
- Reset key
3 - Grüne LED: Betrieb
- Green LED: Normal operation
4 - Gelbe LED: Überlast
- Yellow LED: KNX Bus overload
5 - Rote LED: Reset
- Red LED: Reset
6 - Netzanschlussklemmen
- mains power supply terminal
7 - unverdrosselter Ausgang
- choke free output
** Wirkungsgrad vor der Drossel
** Efciency before choke
®

Chat with your MDT STV manual using AI

Get instant AI answers from your MDT STV manual

Ask anything about the MDT STV. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend STV?

Yes No

Frequently Asked Questions

A

The MDT STV series supplies a stabilized 30VDC SELV output voltage to power KNX components reliably.

Is this answer helpful?

A

Yes, once the underlying fault is resolved, the power supply automatically restarts without manual intervention.

Is this answer helpful?

A

Only the STV-640.02 model includes an additional choke-free output for specific application needs.

Is this answer helpful?

A

Yes, the device must be installed and connected by authorized electricians following local and KNX regulations.

Is this answer helpful?

A

Green means normal operation, yellow signals bus overload, and red indicates a reset has occurred.

Is this answer helpful?

A

It is approved for use in the EU but is strictly prohibited for use in the USA and Canada.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Automatic self-restart after fault clearance reduces manual maintenance needs
  • High efficiency ratings above 82% ensure energy savings during operation
  • Clear multi-color LED indicators simplify troubleshooting and status monitoring
  • Integrated choke protects against noise and ensures stable bus communication
  • Compact DIN rail design fits easily into standard distribution boards
VS

Disadvantages

  • Restricted to EU markets; not approved for use in USA or Canada
  • Requires installation by authorized electricians only per safety guidelines
  • Limited to dry indoor environments preventing outdoor or damp usage
  • STV-160 and STV-320 lack the choke-free output available on STV-640
  • Maximum total current limit applies when using both outputs on STV-640
M: QW-35-FL

Product Specification

Type

Power supply

Standard

KNX

Function

Power supply

Topology

Bus

Features

IP20

M: QW-35-FL

Product Description

Enhancing KNX Systems with the MDT KNX Bus Voltage Supply STV

The MDT KNX Bus Voltage Supply STV series represents a cornerstone for reliable building automation systems. Designed specifically for integration into modern KNX networks, these power supplies deliver a stable 30VDC SELV output essential for powering communication devices across residential and commercial installations. The product line includes models like the STV-160.02, STV-320.02, and STV-640.02, each catering to varying load requirements while maintaining consistent performance standards.

At the heart of the STV design is an integrated choke that filters noise and ensures signal integrity on the bus line. This feature is critical for preventing data corruption in complex setups where multiple devices draw power simultaneously. The system automatically restarts after a fault is cleared, minimizing downtime and reducing the need for manual intervention. The STV-640.02 model stands out by offering an additional choke-free output, providing flexibility for specific applications that require direct power without filtering.

Installation is straightforward, as these units are built for fixed mounting on standard DIN 35mm rails within distribution boards or compact enclosures. They are intended for use in dry indoor environments and comply with strict safety regulations including CE marking for EU markets. The device features clear LED indicators that provide immediate status feedback: a green light signals normal operation, yellow indicates overload conditions, and red denotes a reset event. This visual diagnostics tool allows electricians to quickly identify and resolve issues without specialized testing equipment.

Efficiency is another key highlight, with models boasting efficiency rates exceeding 82% up to 87% under nominal load. Low power loss during idle operation further contributes to energy savings. The robust construction supports wire gauges ranging from 0.5mm² to 4.0mm², ensuring compatibility with various cabling standards. Whether managing a small apartment setup or a large office building, the MDT KNX Bus Voltage Supply STV provides the stability and reliability required for seamless automation control.

Important Notes

  • Always disconnect mains power before installation or maintenance.
  • Installation must be performed by authorized electrical personnel only.
  • Ensure all terminals are covered by panel doors after wiring.
  • Do not use in USA or Canada due to regulatory restrictions.