- ZZP360E303 -
Technische Daten
Technical Data
SCN-P360E3.03
Reichweite
Operating distance
Bewegung*
Movement*
11m
Präsenz*
Presence*
5m
Empndlichkeit
Sensitivity
einstellbar in 10 Stufen
adjustable in 10 steps
Erfassungsbereich
Angular coverage
360°
Dynamikbereich Lichtsensor
Range of light sensor
5 - 1000 Lux
Temperaturmessbereich
Measurement range temperature
-10 bis +50°C
-10 to +50°C
Spezikation KNX Schnittstelle
Specication KNX interface
TP-256
Verfügbare KNX Datenbanken
Available application software
ETS 4/5
Max. Kabelquerschnitt
Permitted wire gauge
KNX Busklemme
KNX screw terminal
0,8mm Ø, solid core
Versorgungsspannung
Power Supply
KNX Bus
Leistungsaufnahme KNX Bus typ.
Power consumption KNX bus typ.
<0,3W
Umgebungstemperatur
Operation temperature range
0 bis + 40°C
Schutzart
Enclosure
IP 20
Abmessungen (Durchmesser x Höhe)
Dimensions (Diameter x Height)
50mm x 52mm
Technische Daten Einbaupräsenzmelder MR16 - Technical Data Presence Detector MR16
1
2
4
SCN-P360E3.03 Frontansicht - Front view SCN-P360E3.03 Rückansicht - Back view
Allgemeine Sicherheitshinweise - Important safety notes
Lebensgefahr durch elektrischen Strom - Danger High Voltage
• Das Gerät darf nur von Elektrofachkräften montiert und angeschlossen werden. Beachten sie die länderspezischen
Vorschriften sowie die gültigen KNX-Richtlinien. Die Geräte sind für den Betrieb in der EU zugelassen und tragen das CE
Zeichen. Die Verwendung in den USA und Kanada ist nicht gestattet.
Installation and commissioning of the device only be carried out by authorised electricans. The relevant standards,
directives, regulations and instructions must be observed. The devices are approved for use in the EU and have the CE
mark. Use in USA and Canada is prohibited.
Anschlussklemmen, Bedien- und Anzeigeelemente Einbaupräsenzmelder MR16
Terminals, Operating and Display Switch Presence Detector MR16
Betriebsanleitung Einbaupräsenzmelder MR16
nur für autorisiertes Elektrofachpersonal
Operating Instructions Presence Detector MR16
for authorised electricans
1 - Busanschlussklemme
- KNX busconnection terminal
2 - Programmiertaster
- Programming key
3 - Rote Programmier LED
- Red programming LED
4 - LED Nachtlicht
- LED night light
S3
S2
S1
S1-S3 - Position Sensoren
S1-S3 - Sensor position
* bei maximaler Einbauhöhe von 4m
* at maximum mounting height of 4m
3
®

Chat with your MDT SCN-P360E3.03 manual using AI

Get instant AI answers from your MDT SCN-P360E3.03 manual

Ask anything about the MDT SCN-P360E3.03. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SCN-P360E3.03?

Yes No

Frequently Asked Questions

A

The device detects movement up to eleven meters away from the sensor unit.

Is this answer helpful?

A

No, it is designed for dry indoor rooms only and has an IP 20 rating unsuitable for weather exposure.

Is this answer helpful?

A

Certain versions support up to three light bands while others manage one band specifically.

Is this answer helpful?

A

Yes, physical programming keys are used along with software uploads through the engineering tool.

Is this answer helpful?

A

It is compatible with application software versions four and five of the standard engineering suite.

Is this answer helpful?

A

Presence detection maintains the signal for five meters depth to recognize stationary figures.

Is this answer helpful?

A

Users can tune sensitivity in ten distinct steps using the configuration parameters.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Adjustable sensitivity in ten steps for customized detection thresholds
  • Integrated KNX bus power eliminates need for external adapters
  • Controls up to three light rows with constant intensity regulation
  • Compact dimensions fit flush into standard ceiling housing
  • Wide temperature range supports diverse indoor climate conditions
VS

Disadvantages

  • Installation restricted to authorized electricians due to safety risks
  • EU market approval excludes direct use in USA and Canada
  • Requires dry indoor locations limiting outdoor deployment options
  • Higher mounting heights require specific tilt adjustments for coverage
  • Light sensor sensitivity may need recalibration during seasonal shifts
M: QW-35-FL

Product Specification

Type

Motion Detector

Sensors

Infrared

Alarm Zones

1

Standard

KNX

Detection Range

36.09 ft

Detection Angle

360°

Operating Temperature

-14°F to 122°F

Dimensions

Dia 1.97 x 2.05 in

Protection Rating

IP20

M: QW-35-FL

Product Description

Enhancing Automation with Intelligent Sensing Solutions

Modern building automation requires reliable hardware that integrates easily into existing frameworks. The MDT KNX MR16 Built-in Presence Detector represents a top-tier choice for professionals installing smart lighting systems. This sensor utilizes advanced technology to distinguish between active movement and passive presence within a room environment. By doing so, it ensures energy is saved while occupants enjoy consistent illumination without frequent flickering or delayed responses. The compact form factor allows it to fit flush into standard ceiling fixtures discreetly.

Comprehensive Sensor Performance

Inside the unit, pyro detectors work alongside a precise optical lens to monitor the space effectively. Coverage extends to eleven meters for basic movement recognition and five meters for true presence detection. Installers can adjust sensitivity across ten different stages to match room dynamics perfectly. Ambient light sensors measure conditions between five and one thousand lux, preventing false activations during sunlight hours. Temperature tolerance spans from minus ten to plus fifty degrees Celsius ensuring reliability in varied climates within dry indoor spaces.

Seamless KNX Bus Integration

Power is supplied directly through the two-wire KNX bus network reducing wiring complexity significantly. Communication protocols comply with the latest ETS version standards allowing easy parameter configuration. Dimming capabilities offer full control from zero to one hundred percent for connected loads. Specialized versions support constant light regulation adjusting output based on available natural resources. This feature manages up to three distinct light bands simultaneously in specific models. HVAC channels receive occupancy signals to optimize heating or cooling cycles based on actual usage patterns rather than fixed timers. Block objects allow blocking specific channels for maintenance or special events easily. Scene modules simplify complex lighting scenarios requiring multi-step transitions between states instantly.

Installation Guidelines and Safety Protocols

Mounting occurs on the ceiling ideally between two and four meters above the floor. Qualified electricians must handle all electrical connections to avoid hazardous situations involving high voltage lines. The device is approved for use in European markets carrying the necessary CE marking compliance. Programming involves uploading address tables and setting parameters via engineering tools followed by physical button presses for confirmation. Visual indicators show success when LEDs turn off after communication completes. Detailed guidance on calibration procedures aligns with expectations set forth in the Motion Detector Manual. Wiring access requires removing the cover plate carefully to reach terminal screws securely. Adhering to national standards is mandatory for insurance and warranty purposes locally.

Long Term Reliability and Maintenance

Enclosure ratings protect internal electronics from dust and solid foreign objects effectively. Dimensions remain small at fifty-two millimeters height maintaining aesthetic appeal. Operational life is extended by drawing low current from the main bus power source. Regular software updates ensure compatibility with future system expansions or changes. Users benefit from reduced maintenance needs compared to older relay-based detection methods commonly found in legacy installations.

Notes: Always verify site requirements before purchasing. Ensure power is disconnected during any wiring activities performed onsite.

M: QW-35-FL

© Copyright 2026 Manual.ly