Technische Daten
Technical Data
SCN-LOG1.02
Spezikation KNX Schnittstelle
Specication KNX interface
TP-256 mit Long Frame Unterstützung für ETS5
TP-256 with long frame support for ETS5
Verfügbare KNX Datenbanken
Available application software
ETS 4/5
Max. Kabelquerschnitt
Permitted wire gauge
KNX Busklemme
KNX busconnection terminal
0,8mm Ø, solid core
Versorgungsspannung
Power Supply
KNX Bus
Leistungsaufnahme KNX Bus typ.
Power consumption KNX Bus typ.
< 0,3W
Temperaturbereich
Operation temperature range
-10 bis + 50°C
Schutzart
Enclosure
IP 20
Abmessungen REG (Teilungseinheiten)
Dimensions MDRC (Space Units)
2TE
Technische Daten Logikmodul SCN-LOG - Technical Data Logic Module SCN-LOG
1
2
3
SCN-LOG.02
Allgemeine Sicherheitshinweise - Important safety notes
Lebensgefahr durch elektrischen Strom - Danger High Voltage
• Das Gerät darf nur von Elektrofachkräften montiert und angeschlossen werden. Beachten sie die länderspezischen
Vorschriften sowie die gültigen KNX-Richtlinien. Die Geräte sind für den Betrieb in der EU zugelassen und tragen das CE
Zeichen. Die Verwendung in den USA und Kanada ist nicht gestattet.
Installation and commissioning of the device only be carried out by authorised electricans. The relevant standards,
directives, regulations and instructions must be observed. The devices are approved for use in the EU and have the CE
mark. Use in USA and Canada is prohibited.
Anschlussklemmen, Bedien- und Anzeigeelemente Logikmodul SCN-LOG
Terminals, Operating and Display Logic Module SCN-LOG
Betriebsanleitung Logikmodul SCN-LOG
nur für autorisiertes Elektrofachpersonal
Operating Instructions Logic Module SCN-LOG
for authorised electricans
1 - Busanschlussklemme
- KNX busconnection terminal
2 - Programmiertaster
- Programming key
3 - Rote Programmier LED
- Red programming LED
4 - LED Anzeigen
- LED indicators
4
®
MDT_AOI_Logic_Module_02.indd 1MDT_AOI_Logic_Module_02.indd 1 11.05.2021 10:15:2111.05.2021 10:15:21

Chat with your MDT Logic Module manual using AI

Get instant AI answers from your MDT Logic Module manual

Ask anything about the MDT Logic Module. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Logic Module?

Yes No

Frequently Asked Questions

A

It creates and executes logical functions for building automation directly within the ETS software, handling up to 24 independent blocks.

Is this answer helpful?

A

No, installation and connection must be performed by authorized electricians due to high voltage risks and safety regulations.

Is this answer helpful?

A

Yes, it computes sunrise, sunset, and evening twilight based on inputted date, time, and geographical location.

Is this answer helpful?

A

The module can store specific values internally to preserve data until power is restored.

Is this answer helpful?

A

Yes, it supports TP-256 with long frame usage specifically designed for compatibility with ETS version 5.

Is this answer helpful?

A

You can download the necessary database and software from the official MDT website under the downloads section.

Is this answer helpful?

A

The device operates safely between -10 degrees Celsius and +50 degrees Celsius.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Supports 24 independent function blocks for versatile logic creation
  • No external software needed; fully configured via ETS
  • Calculates sunrise, sunset, and twilight automatically
  • Compact 2TE design fits easily on DIN rails
  • Includes 4 programmable LEDs for real-time status indication
VS

Disadvantages

  • Restricted to dry indoor environments only
  • Not approved for use in the USA and Canada
  • Requires authorized electrician for installation
  • Limited to KNX bus protocols only
  • Physical address must be assigned manually via ETS
M: QW-35-FL

Product Specification

Type

Sensor, Actuator

Standard

KNX

Function

Logic module, Switch actuator (on/off), On/Off delay, Temperature, Time functions

Topology

Bus

Features

IP20

M: QW-35-FL

Product Description

MDT Logic Module: The Heart of Intelligent Building Automation

The MDT Logic Module, specifically the 2TE REG model, represents a significant leap forward in KNX-based building automation. Designed for professionals who demand efficiency and precision, this device simplifies the creation of complex logic sequences directly within the ETS environment. Unlike traditional systems that require external software or complex coding, this module allows users to configure up to 24 independent function blocks using intuitive parameters. Whether you are managing lighting, ventilation, or security systems, the SCN-LOG provides a robust foundation for seamless operation.

Advanced Functionality at Your Fingertips

At the core of this module lies its versatility. It supports TP-256 with long frame capabilities, ensuring compatibility with modern ETS versions while maintaining high performance. The unit features four front-panel LEDs that can be mapped to any object, providing immediate visual feedback on system status. Beyond basic switching, it calculates astronomical data such as sunrise, sunset, and twilight based on date, time, and location inputs. This makes it ideal for energy-saving strategies that rely on natural light cycles.

Seamless Integration and Installation

Installation is straightforward, fitting securely onto standard DIN 35mm rails in distribution boards. The compact 2-unit width saves valuable space in electrical cabinets. Once mounted and connected to the KNX bus, the device requires no additional tools for programming. Users simply assign a physical address via ETS, upload the application program, and press the dedicated programming key on the module. A red LED indicator confirms successful configuration by turning off, signaling readiness for operation. With support for temperature ranges from -10 to +50 degrees Celsius and an IP 20 rating, it is built to withstand demanding indoor environments.

Why Choose the MDT Logic Module?

This product stands out for its ability to handle diverse tasks like value storage during power failures, telegram monitoring, and PWM conversion. It empowers electricians to build sophisticated control logic without leaving the familiar ETS interface, reducing commissioning time and potential errors. The inclusion of universal calculators and min/max comparators further expands its utility for advanced monitoring applications.