MDT technologies GmbH
•
51766 Engelskirchen
•
Papiermühle 1
Tel.: + 49 - 2263 - 880
•
Fax: + 49 - 2263 - 4588
•
•
www.mdt.de
Stand: 0217
Technische Änderungen und Irrtümer vorbehalten,
Abbildungen können abweichen.
Allgemeine Sicherheitshinweise - Important safety notes Lebensgefahr durch elektrischen Strom - Danger High Voltage
• Das Gerät darf nur von Elektrofachkräften montiert und angeschlossen werden. Beachten sie die länderspezischen
Vorschriften sowie die gültigen KNX-Richtlinien. Die Geräte sind für den Betrieb in der EU zugelassen und tragen das CE
Zeichen. Die Verwendung in den USA und Kanada ist nicht gestattet. Installation and commissioning of the device
only be carried out by authorised electricans. The relevant standards, directives, regulations and instructions must be
observed. The devices are approved for use in the EU and have the CE mark. Use in USA and Canada is prohibited.
• Nach dem Einbau des Gerätes und Zuschalten der Netzspannung kann an den Ausgängen Spannung anliegen.
Über die eingebauten Kanaltaster lassen sich die Ausgänge ausschalten. After Installation and connecting mains power
supply the outputs can be alive. The outputs can be switched OFF using the push buttons on top of the device.
• In eingebauten Zustand kann ein KNX-Bustelegramm die Ausgänge jederzeit spannungsführend schalten.
After installation a KNX bus telegram can switch the outputs alive.
• Vor Arbeitsbeginn am Gerät immer über die vorgeschalteten Sicherungen spannungsfrei schalten.
Disconnect the mains power supply prior to installation or disassembly.
• Alle spannungsführenden Klemmen und Anschlüsse müssen nach der Installation vollständig durch die Schalttafel-
abdeckung berührungssicher verschlossen werden. Die Schalttafelabdeckung darf nicht ohne Werkzeug zu öffnen sein.
All screw terminals and connections under current must be covered completely against touching by the switch panel.
It should not be possible to open the switch panel cover without using tools.
Anschlussklemmen, Bedien- und Anzeigeelemente Schaltakor AMI/AMS
Terminals, Operating and Display Switch Actuator AMI/AMS
Technische Daten
Technical Data
AMS-0416.02
AMS-0816.02
AMS-1216.02
AMI-0416.02
AMI-0816.02
AMI-1216.02
Anzahl Ausgänge
Number of outputs
4 8 12 4 8 12
Strommeßbereich
Current measurement range
10mA - 20A 10mA - 20A
Messungenauigkeit
Measuring inaccuracy
2% 2%
Abtastrate
Sampling rate
2000 Messungen/500ms
2000 samples/500ms
2000 Messungen/500ms
2000 samples/500ms
Maximale Schaltleistung
Output switching ratings
Ohmsche Last
Ohmic loads
16A 16/20A
Kapazitive Last
Capacitive loads
140uF 200uF
Spannung
Voltage
230VAC 230VAC
Maximaler Einschaltstrom
Maximum inrush current
600A/150µs
250A/600µs
600A/150µs
300A/600µs
Maximale Last
Maximum lamp loads
Glühlampen
Incandescent lamps
2500W
3680W
HV- Halogenlampen
Halogen lamp 230V
2500W
3680W
NV- Halogenlampen, elektr. Tranformator
Halogen lamp, electronic transformer
1500W
2000W
Leuchtstofampen unkompensiert
Fluorescent lamp not compensated
2300W
3680W
Leuchtstofampen parallelkompensiert
Fluorescent lamp parallel compensated
1500W
2500W
max. Anzahl EVG (elektronischer Trafo)
max. number of electronic transformers
20
28
Mech. Schalthäugkeit
Output life expectancy (mechanical.)
1.000.000
1.000.000
Spezikation KNX Schnittstelle
Specication KNX interface
TP-256 mit Long Frame Unterstützung für ETS5
TP-256 with long frame support for ETS5
Verfügbare KNX Datenbanken
Available application software
ETS 4/5
Project le for ETS 3 (*.pr5)
ETS 4/5
Project le for ETS 3 (*.pr5)
Max. Kabelquerschnitt
Permitted wire gauge
Schraubklemmen
Screw terminal
1 x (0,5 - 4,0mm²)
2 x (0,5 - 2,5mm²)
1 x (0,5 - 4,0mm²)
2 x (0,5 - 2,5mm²)
KNX Busklemme
KNX busconnection terminal
0,8mm Ø, solid core 0,8mm Ø, solid core
Anzugsmoment Schraubklemme
Torque screw terminal
0,5Nm 0,5Nm
Versorgungsspannung
Power Supply
KNX bus KNX bus
Leistungsaufnahme KNX Bus typ.
Power consumption knx bus typ.
< 0,3W < 0,4W < 0,4W < 0,3W < 0,4W < 0,4W
Umgebungstemperatur
Operation temperature range
0 bis + 45°C 0 bis + 45°C
Schutzart
Enclosure
IP 20 IP 20
Abmessungen REG (Teilungseinheiten)
Dimensions MDRC (Space Units)
4TE 8TE 12TE 4TE 8TE 12TE
1
2
3
4
5
6
AMI/AMS-04xx.02 AMI/AMS-08xx.02
1
2
3
4 4
5
6
Betriebsanleitung Schaltaktor AMI/AMS - nur für autorisiertes Elektrofachpersonal
Operating Instructions Switch Actuator AMI/AMS - for authorised electricans
1 - Busanschlussklemme
- KNX busconnection terminal
2 - Programmiertaster
- Programming key
3 - Rote Programmier LED
- Red programming LED
4 - Anschlussklemmen
- Output power terminal
5 - Grüne Kanalanzeige LED
- Green ON/OFF Led
6 - Taster Handbetätigung
- Buttons for manual actuation
®

Chat with your MDT AMS Gen2 manual using AI

Get instant AI answers from your MDT AMS Gen2 manual

Ask anything about the MDT AMS Gen2. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend AMS Gen2?

Yes No

Frequently Asked Questions

A

No, the device requires the KNX bus for receiving control commands and configuration data. However, it can be operated manually using the built-in push buttons if the bus is unavailable.

Is this answer helpful?

A

All relays hold their current switching position when mains power fails. Upon restoration, the relays remain in that state unless programmed otherwise to return to a default position.

Is this answer helpful?

A

Yes, the MDT Switch Actuator AMS Gen2 fully supports TP-256 communication with long frame support, making it compatible with ETS4 and ETS5 project files.

Is this answer helpful?

A

The device includes an integrated hour meter and current sensors. It calculates active power using voltage and cos phi factors, sending consumption data in mA, A, or kW formats to the bus.

Is this answer helpful?

A

No, the enclosure has an IP20 rating, meaning it is not protected against dust or water. It must be installed in dry indoor rooms only.

Is this answer helpful?

A

The maximum capacitive load varies by model but generally reaches up to 200 microfarads for the higher capacity versions of the actuator series.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Bistable relays maintain switch position during power failures for enhanced safety
  • Integrated current measurement per channel and total sum for precise energy monitoring
  • Supports extensive programming options including scenes, delays, and logical functions via ETS
  • Compact design fits multiple configurations (4, 8, or 12 channels) on standard DIN rails
  • Manual push buttons allow direct local control with clear LED status indicators
VS

Disadvantages

  • Restricted to authorized electricians for installation and commissioning procedures
  • Not certified for use in North America, limiting international deployment options
  • Requires specific KNX bus voltage and proper fusing of outgoing lines for safety
  • Maximum neighboring output current capacity is limited to 32A total
  • Enclosure protection is IP20, suitable only for dry indoor environments
M: QW-35-FL

Product Specification

Type

Actor

Standard

KNX

Function

Switch actuator (on/off), On/off delay

Topology

Bus

Features

IP20

M: QW-35-FL

Product Description

MDT Switch Actuator AMS Gen2: Advanced KNX Control

The MDT Switch Actuator AMS Gen2 represents a pinnacle in intelligent building automation, designed specifically for professionals seeking reliability and precision. This device serves as the central nervous system for managing electrical loads within modern KNX networks. By receiving telegrams from the KNX bus, it controls up to twelve independent outputs simultaneously, ensuring that every light, motor, or appliance operates exactly as intended.

Each output channel is powered by a robust bistable relay, which guarantees energy efficiency and maintains its last known state even during power outages. This feature is crucial for safety and convenience, preventing unexpected switches upon power restoration. The unit allows for complete individual programming via ETS software, enabling complex logical operations, status feedback, blocking functions, and sophisticated time-based scenarios like staircase lighting or delay timers.

Beyond simple switching, the AMS Gen2 offers advanced monitoring capabilities. It measures current on each channel and calculates total consumption, transmitting data in various formats such as milliamperes, amperes, or kilowatts directly to the bus. An integrated service interval counter tracks operating hours, facilitating predictive maintenance and energy management strategies. The device supports long frame protocols compatible with ETS5, ensuring future-proof integration.

Installation is straightforward for authorized electricians. The actuator mounts securely on standard DIN rails and features clear manual operation buttons accompanied by green LEDs for immediate visual feedback. Safety is paramount; all live terminals are enclosed behind tool-accessible covers, and the unit complies with strict EU regulations and CE marking standards. Whether used in residential or commercial settings, this actuator delivers seamless control and detailed diagnostics.

Important Notes

  • Only qualified electricians should install or commission this device.
  • Ensure all connections are fused according to local circuit breaker specifications.
  • The device is approved for EU use only; usage in the USA and Canada is prohibited.
  • Always disconnect mains power before working on the unit to avoid shock hazards.