MDT AKS 16A Manual

0.0 · 0 Ratings

PDF manual · 2 Pages

English

M: OA-GPT-5-NAN
page

/ 2

Loading...
6f4795537becd47ad3e4905dd4020a0a598b page 1
MDT technologies GmbH
•
51766 Engelskirchen
•
Papiermühle 1
Tel.: + 49 - 2263 - 880
•
Fax: + 49 - 2263 - 4588
•
•
www.mdt.de
Stand: 0421
Technische Änderungen und Irrtümer vorbehalten,
Abbildungen können abweichen.
Allgemeine Sicherheitshinweise - Important safety notes Lebensgefahr durch elektrischen Strom - Danger High Voltage
• Das Gerät darf nur von Elektrofachkräften montiert und angeschlossen werden. Beachten sie die länderspezischen
Vorschriften sowie die gültigen KNX-Richtlinien. Die Geräte sind für den Betrieb in der EU zugelassen und tragen das CE
Zeichen. Die Verwendung in den USA und Kanada ist nicht gestattet. Installation and commissioning of the device
only be carried out by authorised electricans. The relevant standards, directives, regulations and instructions must be
observed. The devices are approved for use in the EU and have the CE mark. Use in USA and Canada is prohibited.
• Nach dem Einbau des Gerätes und Zuschalten der Netzspannung kann an den Ausgängen Spannung anliegen.
Über die eingebauten Kanaltaster lassen sich die Ausgänge ausschalten. After Installation and connecting mains power
supply the outputs can be alive. The outputs can be switched OFF using the push buttons on top of the device.
• In eingebauten Zustand kann ein KNX-Bustelegramm die Ausgänge jederzeit spannungsführend schalten.
After installation a KNX bus telegram can switch the outputs alive.
• Vor Arbeitsbeginn am Gerät immer über die vorgeschalteten Sicherungen spannungsfrei schalten.
Disconnect the mains power supply prior to installation or disassembly.
• Alle spannungsführenden Klemmen und Anschlüsse müssen nach der Installation vollständig durch die Schalttafel-
abdeckung berührungssicher verschlossen werden. Die Schalttafelabdeckung darf nicht ohne Werkzeug zu öffnen sein.
All screw terminals and connections under current must be covered completely against touching by the switch panel.
It should not be possible to open the switch panel cover without using tools.
Anschlussklemmen, Bedien- und Anzeigeelemente Schaltakor AKS
Terminals, Operating and Display Switch Actuator AKS
Technische Daten
Technical Data
AKS-0216.03 AKS-1616-03
AKS-0416.03 AKS-1616-03
AKS-0816.03 AKS-2016.03
AKS-1216.03 AKS-2416-03
Anzahl Ausgänge
Number of Outputs
2 4 8 12 16 20 24
Maximale Schaltleistung je Kanal
Output switching ratings
Ohmsche Last
Ohmic loads
16A
Kapazitive Last
Capacitive loads
140uF
Spannung
Voltage
230VAC
Maximaler Einschaltstrom
Maximum inrush current
600A/150µs
250A/600µs
Maximale Last
Maximum lamp loads
Glühlampen
Incandescent lamps
2500W
HV- Halogenlampen
Halogen lamp 230V
2500W
NV- Halogenlampen*
Halogen lamp, electronic transformer
1500W
Leuchtstofampen unkompensiert
Fluorescent lamp not compensated
2300W
Leuchtstofampen parallelkompensiert
Fluorescent lamp parallel compensated
1500W
max. Anzahl EVG (elektronischer Trafo)
max. number of electronic transformers
20
mech. Schalthäugkeit
Output life expectancy (mech.)
1.000.000
Summenstrombelastbarkeit des Aktors
Max. total current of the actuator
32A 64A 96A 128A 128A 192A 192A
Spezikation KNX Schnittstelle
Specication KNX interface
TP-256 mit Long Frame Unterstützung für ETS5
TP-256 with long frame support for ETS5
Verfügbare KNX Datenbanken
Available application software
ETS 4/5
Max. Kabelquerschnitt
Permitted wire gauge
Schraubklemmen
Screw terminal
1 x (0,5 - 4,0mm²)
2 x (0,5 - 2,5mm²)
KNX Busklemme
KNX busconnection terminal
0,8mm Ø, solid core
Anzugsmoment Schraubklemme
Torque screw terminal
0,5Nm
Versorgungsspannung
Power Supply
via KNX bus
Leistungsaufnahme KNX Bus typ.
Power Consumption KNX bus typ.
<0,25W <0,25W <0,25W <0,3W <0,3W <0,3W <0,3W
Umgebungstemperatur
Operation temperature range
0 bis + 45°C
Schutzart
Enclosure
IP 20
Abmessungen (Teilungseiheiten)
Design MDRC (Space Units)
2TE 4TE 6TE 8TE 8TE 12TE 12TE
Technische Daten Schaltaktor AKS - Technical Data Switch Actuator AKS
* gilt für NV- Halogenlampen mit elektroischem Transformator
* low voltage halogen lamps with electronic transformator
1
2
3
4
5
6
AKS-0816.03 AKS-2016.03
1
2
3
4 4
5
6
Betriebsanleitung Schaltaktor AKS - nur für autorisiertes Elektrofachpersonal
Operating Instructions Switch Actuator AKS - for authorised electricans
1 - Busanschlussklemme
- KNX busconnection terminal
2 - Programmiertaster
- Programming key
3 - Rote Programmier LED
- Red programming LED
4 - Anschlussklemmen
- Output power terminal
5 - Grüne Kanalanzeige LED
- Green ON/OFF Led
6 - Taster Handbetätigung
- Buttons for manual actuation
®

Chat with your MDT AKS 16A manual using AI

Get instant AI answers from your MDT AKS 16A manual

Ask anything about the MDT AKS 16A. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend AKS 16A?

Yes No

Frequently Asked Questions

A

The AKS supports resistive and capacitive loads, incandescent and halogen lamps, fluorescent lamps (compensated and not compensated) and electronic transformers. Each channel is rated 16A and designed for significant inrush currents.

Is this answer helpful?

A

Programming is done via ETS (supports ETS4/5). Assign a physical address, create and load the application into the actuator, then confirm programming by pressing the onboard programming key; the red LED indicates programming status.

Is this answer helpful?

A

Yes. Each channel has a manual push-button and a green LED showing ON/OFF state, allowing local switching independent of KNX commands.

Is this answer helpful?

A

All relays retain their current switching position during a bus voltage loss. After power returns, each channel’s post-recovery behavior can be configured individually via ETS.

Is this answer helpful?

A

Installation must be by authorised electricians. Mount on a 35mm DIN rail in dry indoor locations, connect to the KNX bus, fuse switching outputs with upstream circuit breakers, and ensure all live terminals are covered and inaccessible after wiring.

Is this answer helpful?

A

Screw terminals accept typical wire gauges (e.g., 0.5–4.0 mm² for single conductor, depending on model). The KNX bus terminal accepts 0.8mm solid core. Use correct torque (about 0.5 Nm) on terminals.

Is this answer helpful?

A

Yes. The AKS is designed to withstand high inrush currents and is suitable for heavy C-loads and lamp circuits requiring robust switching capability.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High per-channel capacity: 16A per channel suitable for heavy loads and high inrush currents.
  • Compact DIN-rail design: high channel density reduces required distribution space and per-channel cost.
  • Per-channel L terminals and manual push-buttons: simplifies wiring and local control.
  • Flexible ETS programmability: supports logical functions, delays, scenes and status feedback.
  • State retention on bus outage: relays hold position and behavior can be parameterized after power return.
VS

Disadvantages

  • EU-only approval: not certified for use in USA or Canada, limiting international deployments.
  • IP20 enclosure: suitable only for dry indoor installations, not for damp or outdoor locations.
  • Requires authorised electrician for installation: not intended for DIY users.
  • Need for upstream fuses: each switching contact must be protected by circuit breakers, adding installation steps.
  • Relies on ETS and KNX expertise: full functionality requires familiarity with ETS tool and KNX commissioning.
M: OA-GPT-5-NAN

Product Specification

Type

Actuator

Standard

KNX

Function

Switching actuator (on/off), On/Off delay

Topology

Bus

Special features

IP20

M: OA-GPT-54-NAN

Product Description

MDT Schaltaktor AKS 16A Manual

The MDT Schaltaktor AKS 16A is a compact, high-performance KNX switch actuator designed for reliable control of lighting and resistive or capacitive loads. Built for DIN-rail installation in distribution boards, the AKS series packs multiple channels into a small footprint and supports up to 16A per channel. It uses bistable relays for low standby power and retains relay positions during KNX bus outages. Each channel has a dedicated L terminal, manual push-button, and a green status LED, making local operation and status checks simple and clear.

The AKS family supports a variety of load types including incandescent, halogen, fluorescent (compensated and non-compensated) and electronic transformers, and is engineered to handle high inrush currents typical of lamps and certain electronic loads. Parameters for each output are set via ETS (supports ETS4/5 and TP-256 long frame), enabling flexible configuration: logical links, status feedback, lock functions, central switching, delays, staircase lighting and scene control. For commissioning, assign a physical address, download the application to the device, and confirm programming with the on-board key and LED.

Installation is intended for authorised electricians only. The actuator is powered via the KNX bus and requires upstream circuit protection on switching contacts. Terminals accept common wire gauges and the unit is rated IP20 for indoor dry locations. Typical use cases include apartment buildings, commercial lighting circuits, and distribution panels where space efficiency and high switching capability are priorities.

Why choose the AKS 16A? It reduces per-channel cost by increasing channel density while maintaining robust switching performance. It’s a practical choice where mixed lighting types and high inrush currents are present. With per-channel programmability via ETS and manual override buttons, it blends automation flexibility with straightforward local control.

Notes:

  • Only use the AKS in EU regions; it is CE marked and not approved for use in the USA/Canada.
  • Disconnect mains before installation and ensure all live terminals are covered and inaccessible after wiring.
  • For best results, download the latest application database and ETS support from MDT before commissioning.
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly