MDT AIO-0410V.01 Manual

0.0 · 0 Ratings

PDF manual · 2 Pages

English

M: QW-35-FL
page

/ 2

Loading...
74ce2db2841c0f64b78c77bc983b8ded328a page 1
MDT technologies GmbH
•
51766 Engelskirchen
•
Papiermühle 1
Tel.: + 49 - 2263 - 880
•
Fax: + 49 - 2263 - 4588
•
•
www.mdt.de
Stand: 1221
Technische Änderungen und Irrtümer vorbehalten,
Abbildungen können abweichen.
Technische Daten
Technical Data
AIO-0210V.01 AIO-0410V.01
Anzahl der Kanäle
Number of channels
2
4
Eingänge
Inputs
Eingangsspannung
Input voltage
0-10V
2-10V
0-10V
2-10V
Innenwiderstand
Internal resistance
130kΩ 130kΩ
Bereich Stromschleife
Range of current loop
0-20mA
4-20mA
0-20mA
4-20mA
Widerstand
Resistance
266Ω 266Ω
Ausgänge
Outputs
Ausgangsspannung
Output voltage
0-10V 0-10V
Ausgangsstrom max.
Output current max.
2mA 2mA
Lastwiderstand min.
Load resistance min.
5kΩ 5kΩ
Spezikation KNX Schnittstelle
Specication KNX interface
TP-256 TP-256
Verfügbare KNX Datenbanken
Available application software
ETS 4/5 ETS 4/5
Max. Kabelquerschnitt
Permitted wire gauge
Schraubklemmen (max. 0,5Nm Anzugsm.)
Screw terminal (max. 0,5Nm tight. torque)
0,5 - 4,0mm² solid core
0,5 - 2,5mm² nely stranded
0,5 - 4,0mm² solid core
0,5 - 2,5mm² nely stranded
KNX Busklemme
KNX busconnection terminal
0,8mm² 0,8mm²
Versorgungsspannung
Power Supply
KNX bus KNX bus
Leistungsaufnahme typ.
Power consumption
<0,3W <0,3W
Umgebungstemperatur
Operation temperature range
0 bis + 40°C 0 bis + 40°C
Schutzart
Enclosure
IP 20 IP 20
Abmessungen REG (Teilungseinheiten)
Dimensions MDRC (Space Units)
-- 2TE
Abmessungen UP (B x H x T)
Dimensions UP (W x H x D)
41mm x 41mm x 12mm --
Technische Daten Analog In-/Output - Technical Data Analog In-/Output
1 2 3
4
AIO-0210V.01
Allgemeine Sicherheitshinweise - Important safety notes
Lebensgefahr durch elektrischen Strom - Danger High Voltage
• Das Gerät darf nur von Elektrofachkräften montiert und angeschlossen werden. Beachten sie die länderspezischen
Vorschriften sowie die gültigen KNX-Richtlinien. Die Geräte sind für den Betrieb in der EU zugelassen und tragen das CE
Zeichen. Die Verwendung in den USA und Kanada ist nicht gestattet.
Installation and commissioning of the device only be carried out by authorised electricans. The relevant standards,
directives, regulations and instructions must be observed. The devices are approved for use in the EU and have the CE
mark. Use in USA and Canada is prohibited.
Betriebsanleitung Analog Ein-/Ausgang
nur für autorisiertes Elektrofachpersonal
Operating Instructions Analog In-/Output
for authorised electricans
Anschlussklemmen, Bedien- und Anzeigeelemente Analog In-/Output
Terminals, Operating and Display Analog In-/Output
1 - Busanschlussklemme
- KNX busconnection terminal
2 - Programmiertaster
- Programming key
3 - Rote Programmier LED
- Red programming LED
4 - Anschlusskabel
- Connection cables
Zwischen KNX Buskabeln/Eingangsleitungen und den 230V Leitungen ist ein Abstand von mindestens 4mm einzuhalten. Es sind die
gültigen Normen und Richtlinien zu Leitungsabständen einzuhalten.
Between KNX bus cables/Input cables and the 230V cables the minimum gap has to be 4mm. The applicable standards and
regulations must be observed.
Wichtiger Einbauhinweis - Important assembly note
AIO-0410V.01
5 - Anschlussklemmen
- Connection screw terminal
1
2
3
5
®

Chat with your MDT AIO-0410V.01 manual using AI

Get instant AI answers from your MDT AIO-0410V.01 manual

Ask anything about the MDT AIO-0410V.01. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend AIO-0410V.01?

Yes No

Frequently Asked Questions

A

No, the device is designed exclusively for dry indoor environments and lacks weatherproofing ratings for outdoor use.

Is this answer helpful?

A

Yes, the device relies entirely on ETS software for addressing and parameterization, so the software is mandatory.

Is this answer helpful?

A

The system automatically activates an emergency mode to maintain safe operation until the issue is resolved.

Is this answer helpful?

A

Yes, all channels are galvanically isolated from the KNX bus to prevent electrical faults and interference.

Is this answer helpful?

A

Yes, each channel can be configured individually in ETS to act as either a voltage or current loop input.

Is this answer helpful?

A

The typical power consumption is less than 0.3 Watts, making it highly energy efficient.

Is this answer helpful?

A

Yes, every output includes a day/night function to limit control values based on scheduled times.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Galvanic isolation ensures high safety and signal integrity across all channels
  • Flexible configuration allows independent setting of inputs and outputs per channel
  • Comprehensive ETS support enables detailed parameterization like thresholds and unit conversion
  • Dual form factors provide options for both DIN rail and flush mounting applications
  • Built-in safety features include automatic emergency mode and day/night limiting functions
VS

Disadvantages

  • Restricted to use only in dry indoor environments with no outdoor rating
  • Installation requires strict adherence to voltage separation guidelines for safety
  • Not approved for use in the USA and Canada, limiting global deployment options
  • Requires professional programming via ETS which may have a learning curve for beginners
  • Limited to specific wire gauges which might require adapters for non-standard cabling
M: QW-35-FL

Product Specification

Type

Actor

Standard

KNX

Features

IP20

M: QW-35-FL

Product Description

MDT Analog Input/Output AIO: The Ultimate Control Solution

The MDT Analog Input/Output AIO represents a pinnacle in smart building automation, designed specifically for professionals seeking precision and flexibility. This device serves as a robust bridge between the KNX bus system and analog field devices, enabling seamless control of equipment with 0-10V inputs while simultaneously capturing critical measurement data from sensors operating on 0-20mA or 4-20mA loops.

What sets this product apart is its incredible versatility. Every channel within the unit is galvanically isolated from the KNX bus, ensuring safety and preventing electrical interference. Users can configure each channel independently as either an input or an output, adapting to the unique needs of any installation. Whether you are managing heating systems, lighting controls, or environmental monitoring, the AIO adapts effortlessly.

The configuration process is intuitive thanks to full compatibility with ETS software. Engineers can individually parameterize each input to define specific min/max limits, threshold values, and even traffic light functions. The ability to convert measuring units and adjust Data Point Types (DPT) directly in the software streamlines the commissioning phase significantly. On the output side, the device delivers a stable 0-10V signal controllable via 1-byte, 2-byte, or 1-bit objects. Safety features are built-in; if the control value fails, the system automatically switches to emergency mode, and a day/night function allows for precise limiting of control values based on time of day.

Available in two distinct physical forms, the AIO caters to diverse installation requirements. The modular version fits perfectly onto standard DIN rails, ideal for distribution boards, while the flush-mounted variant integrates discreetly into switch boxes for fixed installations in dry indoor environments. Both versions operate reliably within temperatures ranging from 0 to +40 degrees Celsius and consume less than 0.3W of power, making them energy-efficient choices for modern green buildings.

Key Notes for Installers

Ensure that all wiring adheres to the mandatory 4mm separation distance between KNX bus cables and 230V mains lines to prevent hazards. Only authorized electricians should perform installation and commissioning tasks. Remember to download the latest application software from the manufacturer before starting the setup process to ensure optimal performance and compatibility.

Pros and Cons

Pros

  • Galvanic isolation ensures high safety and signal integrity across all channels.
  • Flexible configuration allows independent setting of inputs and outputs per channel.
  • Comprehensive ETS support enables detailed parameterization like thresholds and unit conversion.
  • Dual form factors provide options for both DIN rail and flush mounting applications.
  • Built-in safety features include automatic emergency mode and day/night limiting functions.

Cons

  • Restricted to use only in dry indoor environments with no outdoor rating.
  • Installation requires strict adherence to voltage separation guidelines for safety.
  • Not approved for use in the USA and Canada, limiting global deployment options.
  • Requires professional programming via ETS which may have a learning curve for beginners.
  • Limited to specific wire gauges which might require adapters for non-standard cabling.

Frequently Asked Questions

Q: Can I use the MDT AIO outdoors? A: No, the device is designed exclusively for dry indoor environments and lacks weatherproofing ratings for outdoor use.

Q: Is programming difficult without ETS software? A: Yes, the device relies entirely on ETS software for addressing and parameterization, so the software is mandatory.

Q: What happens if the control signal fails? A: The system automatically activates an emergency mode to maintain safe operation until the issue is resolved.

Q: Are the inputs and outputs isolated from the KNX bus? A: Yes, all channels are galvanically isolated from the KNX bus to prevent electrical faults and interference.

Q: Can I change the input type dynamically? A: Yes, each channel can be configured individually in ETS to act as either a voltage or current loop input.

Q: What is the maximum power consumption? A: The typical power consumption is less than 0.3 Watts, making it highly energy efficient.

Q: Is there a day/night function available? A: Yes, every output includes a day/night function to limit control values based on scheduled times.

M: QW-35-FL

© Copyright 2026 Manual.ly