Manual.ly Logo

Jung Pumpen U6 Manual

0.0 · 0 Ratings

PDF manual · 76 Pages

English

M: OA-GPT-5-NAN
page

/ 76

Loading...
d7006a1d9d228c9fe2dd79efdaf126a813bd page 9
9 9
ENGLISH
You have purchased a product made by
JUNG PUMPEN and with it, therefore, also
excellent quality and service. Secure this
service by carrying out the installation
works in accordance with the instruc-
tions, so that our product can perform
its task to your complete satisfaction.
Please remember that damage caused
by incorrect installation or handling will
adversely affect the guarantee. There-
fore please adhere to the instructions in
this manual!
This appliance can be used by children
aged 8 years or over and by persons with
limited physical, sensory or intellectual
capabilities, or with limited experience
and knowledge, provided that they are
supervised or have been instructed in
the safe use of the appliance and are
aware of the dangers involved. Children
must not be allowed to play with the ap-
pliance. Cleaning and user maintenance
must not be carried out by children un-
less they are supervised.
Damage prevention in case of failure
Like any other electrical device, this product
may fail due to a lack of mains voltage or a tech-
nical defect.
If damage (including consequential damage) can
occur as a result of product failure, the following
precautions can be taken at your discretion:
• Installation of a water level dependent (under
circumstances, mains-independent) alarm
system, so that the alarm can be heard before
damage occurs.
• Inspection of the collecting tank/chamber for
tightness up to the top edge before – or at the
latest, during – installation or operation of the
product.
• Installation of backow protection for drain-
age units that can be damaged by wastewater
leakage upon product failure.
• Installation of a further product that can com-
pensate in case of failure of the other product
(e.g. duplex unit).
• Installation of an emergency power genera-
tor.
As these precautions serve to prevent or mini-
mise consequential damage upon product fail-
ure, they are to be strictly observed as the man-
ufacturer’s guideline – in line with the standard
DIN EN specications as state of the art – when
using the product (Higher Regional Court Frank-
furt/Main, Ref.: 2 U 205/11, 06/15/2012).
SAFETY INSTRUCTIONS
This instruction manual contains essential in-
formation that must be observed during instal-
lation, operation and servicing. It is therefore
important that the installer and the responsible
technician/operator read this instruction manu-
al before the equipment is installed and put into
operation. The manual must always be available
at the location where the pump or the plant is
installed.
Failure to observe the safety instructions can
lead to the loss of all indemnity.
In this instruction manual, safety information is
distinctly labelled with particular symbols. Dis-
regarding this information can be dangerous.
General danger to people
Warning of electrical voltage
NOTICE! NOTICE!
Danger to equipment and operation
Qualication and training of personnel
All personnel involved with the operation, ser-
vicing, inspection and installation of the equip-
ment must be suitably qualied for this work
and must have studied the instruction manual
in depth to ensure that they are suciently
conversant with its contents. The supervision,
competence and areas of responsibility of the
personnel must be precisely regulated by the

Chat with your Jung Pumpen U6 manual using AI

Get instant AI answers from your Jung Pumpen U6 manual

Ask anything about the Jung Pumpen U6. Answers come from this manual, with the pages they are based on.

U6 Maintenance Schedule

As needed
Check mains cable for damage

Inspect the power cord for mechanical or chemical damage. Replace damaged or kinked cables only through the manufacturer.

As needed
Clean float and foot strainer

Regularly clean the float and foot strainer to ensure maximum performance. This prevents coarse impurities from entering the pump.

As needed
Clean impeller

Remove the foot strainer and unscrew the underside cover to access the impeller for cleaning if blocked or obstructed.

As needed
Inspect impeller for wear

If pumping performance decreases, check the impeller for wear and sharp edges. Replace worn parts only via the manufacturer.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend U6?

Yes No

Frequently Asked Questions

A

The U6 series pumps domestic faecal-free wastewater (including water from washing machines and dishwashers). The U6K variant additionally handles groundwater, drainage water, silage juice and liquid fertilisers within specified limits.

Is this answer helpful?

A

Yes, outdoor installations require models fitted with at least a 10-metre mains cable. Always follow local regulations and ensure RCD protection (≤30 mA) and appropriate fusing (minimum 10 A slow-blow) for safe outdoor use.

Is this answer helpful?

A

Regularly clean the foot strainer and float, inspect and clean the impeller if blocked, and check the power cable for damage. In iron- or lime-rich water, increase cleaning frequency to prevent seal and motor damage.

Is this answer helpful?

A

Only qualified electricians should perform electrical work. Observe the nameplate voltage, use RCD protection, and for three-phase units verify correct rotation (startup jolt counter-clockwise). If rotation is wrong, swap two supply phases.

Is this answer helpful?

A

Yes—using specific steps: remove the foot strainer and, where applicable, lock the float switch in ON. Models can pump down to a few millimetres (U5K: ~6 mm, U6K: ~10 mm) but switching mode is not possible in low-level pumping.

Is this answer helpful?

A

Install level-dependent alarms, verify tank/sump tightness, fit backflow prevention, consider duplicate pumps or emergency power, and follow local standards (e.g., EN 12056) to minimise consequential damage.

Is this answer helpful?

A

Disconnect power, remove the foot strainer, open the lower screws and clean the impeller and housing. Check for worn impellers and replace through the manufacturer if needed; also inspect pressure lines and non-return valves for blockages.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Versatile: handles domestic wastewater plus groundwater, drainage and agricultural liquids (U6K).
  • Multiple installation options: base, guide-rail coupling or duplex setup for redundancy.
  • Built-in protections: winding thermostat, recommended RCD and fusing for safe operation.
  • Serviceable design: accessible impeller and foot strainer for cleaning and blockage removal.
  • Shallow pumping capability and options to enlarge free passage for larger solids.
VS

Disadvantages

  • Not suitable for pumping sewage containing solids with fecal matter (faecal-free wastewater only).
  • Requires qualified electrician for electrical work and correct three-phase phase rotation checks.
  • Mobile operation restrictions: vertical use only and must use foot strainer; hose must be emptied before submersion.
  • Regular maintenance required in iron- or lime-rich water to avoid seal damage and motor failure.
  • Some modifications (e.g., enlarging passage) may prevent use of the foot strainer and change operating constraints.
M: OA-GPT-5-NAN

Product Specification

Flow rate

3962.32 gal/h

Delivery head

29.53 ft

Pressure connection

1 1/4"

Special features

without Tank, IP68

M: OA-GPT-54-NAN

Product Description

Jung Pumpen U6 — Reliable Submersible Utility Pump

The Jung Pumpen U6 is a versatile, robust submersible pump designed for domestic wastewater and a range of drainage tasks. Engineered to handle household effluent—such as water from washing machines and dishwashers—the U6 also supports groundwater, drainage water, silage juice and liquid fertilizers in its K variant. It is built for dependable everyday performance with safety and maintenance in mind.

Compact and user-focused, the U6 features corrosion-resistant construction, a protective foot strainer, and an impeller accessible for cleaning or service. Models with integrated float switches provide automatic on/off control while other variants support external level controls and guide-rail installations for fixed sump stations. The pump’s design includes options to enlarge free passage and a flushing modification to reduce sediment build-up in the intake area.

Key practical attributes include frost resistance in storage (to -20°C), a maximum pumped-medium temperature of 35°C, and straightforward mounting options: base plate, guide-rail coupling or duplex installations for redundancy. Electrical safety is emphasised: only qualified electricians should perform connections, and use of RCD-protected outlets (≤30 mA) plus appropriate fusing is required. The U6 includes a winding thermostat for thermal protection and provides guidance on phase rotation for three-phase units.

Maintenance is simple but essential: regular cleaning of the foot strainer and float, periodic inspection of the impeller for wear, and ensuring the power cable is undamaged. The manual explains procedures for clearing blockages, venting the housing, and preparing the pump for shallow pumping (down to a few millimetres with specific steps). It also details safety measures, installation clearances, and legal/regulatory considerations for installation and operation.

Beyond technical guidance, the U6’s documentation stresses risk mitigation for failure scenarios—suggesting alarm systems, backflow protection, redundancy or emergency power—so that consequential damage from pump failure is minimised. Overall, the Jung Pumpen U6 is positioned as a dependable, maintainable choice for domestic and small commercial wastewater lifting and drainage needs.

Notes

  • U6K variant extends application to groundwater, drainage and agricultural liquids.
  • For outdoor use, use pumps with ≥10 m cable.
  • Observe local regulations (e.g., EN 12056, VDE) and install RCD protection.
  • Regular cleaning prevents seal and motor damage in iron- or lime-rich water.
M: OA-GPT-5-NAN