case of pumps with an attached control, the oat switch must
be locked in the ON position. It is not possible therefore in low
level pumping to operate the pump in switching mode.
To make the pump operate, the drainage hose must be emptied
before each pumping run and there must be a 40mm minimum
water level available.
NOTICE! If the pump is malfunctioning, part of the contents of
the oil reservoir could escape into the pumping medium.
NOTICE! The oats of the level controller and alarm system
(accessory) are installed so that they are freely movable but
not under the inlet. Please observe the minimum distances,
see installation example. The controls may only be installed in
a dry and well ventilated room!
CAUTION!
For safety reasons, mobile operation is only allowed vertically
and with a foot strainer!
If a hose is used as a pressure line, care must be taken to en-
sure that for every pumping operation the hose is completely
empty before the pump is submersed. Any residual liquid would
obstruct the ventilation of the pump housing and therefore
also hinder the pumping operation. For the same reason, the
pump would not operate if it was switched on before being sub-
mersed.
CLEANING
WARNING!
Before carrying out any works: disconnect the pump and the
controls from the mains and take steps to ensure that no one
else can reconnect them to the power supply.
WARNING!
Check the mains cable for signs of mechanical and chemical
damage.
Damaged or kinked cables must be replaced by the
manufacturer.
NOTICE! If the water contains high levels of iron or lime, insuf-
cient cleaning can result in irreparable damage to the seal
and thus also to the pump motor in the long term. Consequent-
ly, the pump must be cleaned at regular intervals according to
the hardness of the water.
Tightening torque M
A
for A2 screw materials
for M 5 M
A
= 5 Nm
for Amtec
3 M
A
= 0,7 Nm
for Amtec
5 M
A
=
2 Nm
QUICK TIPS FOR REMEDYING
FAULTS
Pump does not work
• Check mains current (do not use a pin gauge)
• Fuse faulty = may be too weak (please refer to Electrical Con-
nection)
• Mains supply cable damaged = repair to be carried out by
manufacturer only
Pump runs but does not pump
• Empty the pressure pipe or hose to allow the non-return val-
ve to open and the air to escape from the pump housing, it
may be necessary to carry out a ventilation drilling
Impeller blocked
• Solids and brous matter have become lodged in the pump
housing = clean
Decreased pumping performance
• Foot strainer obstructed = clean
• Pressure pipe obstructed = clean
• Rotor worn out = repair to be carried out by the manufacturer
0197
JUNG PUMPEN GmbH - Industriestr. 4-6
33803 Steinhagen, Germany
20
401.17-22.02
EN 12050-2:2001; 2015
Lifting plant for faecal-free wastewater DN 32
U3 K (JP50002)
U3 KS (JP50000)
U3 KS (JP50001)
U3 K spez. (JP50007)
U3 KS spez. (JP50005)
U3 KS spez. (JP50006)
Collecting and automatically lifting faecal-free
waste water above the backow level in buildings
and sites
REACTION TO FIRE NPD
WATERTIGHTNESS Pass
EFFECTIVENESS (LIFTING EFFECT
- Pumping of solids Pass
- Pipe connections Pass
- Ventilation NPD
- Minimum ow velocity Pass
-
Minimum free passage of the plant
Pass
- Minimum useful volume NPD
MECHANICAL RESISTANCE
- Load bearing capacity and structural
stability of collection tank for use
NPD
- Structural stability of collection tank
for use inside buildings
NPD
NOISE LEVEL 70 dB(A)
DURABILITY
- of structural stability NPD
- of lifting effectiveness Pass
- of mechanical resistance NPD
DANGEROUS SUBSTANCES
NPD

Chat with your Jung Pumpen U3 manual using AI

Get instant AI answers from your Jung Pumpen U3 manual

Ask anything about the Jung Pumpen U3. Answers come from this manual, with the pages they are based on.

U3 Maintenance Schedule

Regularly
Clean the pump

Clean regularly depending on water hardness to prevent seal and motor damage from iron or lime deposits. Disconnect power before cleaning.

Before each pumping operation
Empty drainage hose

For flat suction or mobile use with a hose, ensure the drainage hose is completely empty before submerging the pump to allow proper venting.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend U3?

Yes No

Frequently Asked Questions

A

The U3 series is designed for domestic waste water without stones, including water from washing machines and dishwashers. The U3 K Spezial can also pump aqueous solutions with up to 10 percent salt and condensate from gas boilers.

Is this answer helpful?

A

Yes, the pump is frost resistant down to minus 20 degrees Celsius when stored in dry conditions. However, once installed in water, it must never be allowed to freeze.

Is this answer helpful?

A

The pump has a built-in thermostat that shuts off during high temperatures caused by dry running or overload. Always ensure the pump is connected to the correct voltage and avoid running it without water.

Is this answer helpful?

A

Mobile operation is permitted only with the foot strainer attached. You must empty any drainage hose before submerging the pump to allow proper venting and operation.

Is this answer helpful?

A

The pump must be connected to sockets protected by at least a 10 amp slow-blow fuse and a residual current device (RCD) rated at 30 milliamps or less.

Is this answer helpful?

A

Regular cleaning is recommended based on water hardness. In areas with high iron or lime content, frequent cleaning is necessary to prevent seal and motor damage.

Is this answer helpful?

A

If the impeller is blocked by solids or fibers, you must remove the foot strainer, unscrew the bottom cover, and clean the impeller carefully. Check for wear and replace if necessary.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Handles domestic wastewater from washing machines and dishwashers effectively
  • U3 K Spezial version tolerates saline solutions up to 10 percent and boiler condensate
  • Built-in thermal protector prevents motor damage from overheating or dry running
  • Low noise operation stays under 70 decibels for quiet indoor use
  • Can pump surfaces down to very low water levels with minimal residue left behind
VS

Disadvantages

  • Auto-restart feature after cooling creates a safety hazard if not manually disconnected
  • Requires specific 10-amp fuses and RCD protection for safe electrical connection
  • Impeller wear may occur faster in water with high iron or lime content without regular cleaning
  • Maintenance requires disconnecting power and careful handling of sharp edges on worn parts
  • Mobile operation strictly requires a foot strainer for safety compliance
M: QW-35-FL

Product Specification

Pressure connection

1.25 in

M: QW-35-FL

Product Description

Jung Pumpen U3: Reliable Domestic Wastewater Solutions

The Jung Pumpen U3 series represents a pinnacle of engineering for domestic wastewater management. Designed specifically for pumping household dirty water without stones, these submersible pumps are ideal for handling effluent from washing machines and dishwashers. The U3 K Spezial variant extends this capability further, capable of managing aqueous solutions with up to 10% salt content as well as condensate from gas condensing boilers. This versatility makes the U3 an essential component for modern homes and small commercial buildings requiring efficient drainage.

Safety is paramount in the design of the U3. The pump features a winding thermostat that automatically cuts power if temperatures become unacceptably high, preventing damage from dry running or electrical overload. However, users must remember that the pump will restart automatically once cooled, posing a potential injury risk if not disconnected first. Installation requires strict adherence to safety guidelines, including the use of qualified electricians and ensuring proper grounding with at least a 10-amp fuse and a residual current device. The pump is frost-resistant down to -20 degrees Celsius when stored dry, but it must never be allowed to freeze while installed in water.

Operationally, the U3 is built for efficiency and ease of maintenance. It can pump flooded areas leaving only minimal residual water, such as 5 millimeters for the U3K model. For mobile operations, the pump includes a foot strainer to prevent clogging and ensure safe venting. Regular cleaning of the foot strainer and impeller is crucial, especially in hard water areas, to maintain peak performance and prevent seal damage. The system supports both single and duplex installations, offering flexibility for various basement or utility room configurations. With noise levels kept below 70 dB(A), the U3 operates quietly, making it suitable for indoor environments without causing disturbance.

M: QW-35-FL

© Copyright 2026 Manual.ly