Manual.ly Logo

Jung Pumpen Simer 5 Manual

0.0 · 0 Ratings

PDF manual · 48 Pages

English

M: QW-35-FL
page

/ 48

Loading...
636a128d27127f216513b7ef03502cfb17d7 page 6
6 6
ENGLISH
You have purchased a product made by
Pentair Jung Pumpen
and with it, there-
fore, also excellent quality and service.
Secure this service by carrying out the
installation works in accordance with
the instructions, so that our product can
perform its task to your complete satis-
faction. Please remember that damage
caused by incorrect installation or han-
dling will adversely affect the guarantee.
This appliance can be used by children
aged 8 years or over and by persons with
limited physical, sensory or intellectual
capabilities, or with limited experience
and knowledge, provided that they are
supervised or have been instructed in
the safe use of the appliance and are
aware of the dangers involved. Children
must not be allowed to play with the ap-
pliance. Cleaning and user maintenance
must not be carried out by children un-
less they are supervised.
Damage prevention in case of failure
Like any other electrical device, this product
may fail due to a lack of mains voltage or a tech-
nical defect.
If damage (including consequential damage) can
occur as a result of product failure, the following
precautions can be taken at your discretion:
• Installation of a water level dependent (under
circumstances, mains-independent) alarm
system, so that the alarm can be heard before
damage occurs.
• Inspection of the collecting tank/chamber for
tightness up to the top edge before – or at the
latest, during – installation or operation of the
product.
• Installation of backow protection for drainage
units that can be damaged by wastewater leak-
age upon product failure.
• Installation of a further product that can com-
pensate in case of failure of the other product
(e.g. duplex unit).
• Installation of an emergency power genera-
tor.
As these precautions serve to prevent or mini-
mise consequential damage upon product fail-
ure, they are to be strictly observed as the man-
ufacturer’s guideline – in line with the standard
DIN EN specications as state of the art – when
using the product (Higher Regional Court Frank-
furt/Main, Ref.: 2 U 205/11, 06/15/2012).
SAFETY
INSTRUCTIONS
This instruction manual contains essential infor-
mation that must be observed during installation,
operation and servicing. It is therefore important
that the installer and the responsible technician/
operator read this instruction manual before the
equipment is installed and put into operation.
The manual must always be available at the loca-
tion where the pump or the plant is installed.
Failure to observe the safety instructions can
lead to the loss of all indemnity.
In this instruction manual, safety information is
distinctly labelled with particular symbols. Dis-
regarding this information can be dangerous.
General danger to people
Warning of electrical voltage
NOTICE!
Danger to equipment and operation
Qualication and training of personnel
All personnel involved with the operation, servic-
ing, inspection and installation of the equipment
must be suitably qualied for this work and must
have studied the instruction manual in depth
to ensure that they are suciently conversant
with its contents. The supervision, competence
and areas of responsibility of the personnel
must be precisely regulated by the operator. If
the personnel do not have the necessary skills,
they must be instructed and trained accordingly.

Chat with your Jung Pumpen Simer 5 manual using AI

Get instant AI answers from your Jung Pumpen Simer 5 manual

Ask anything about the Jung Pumpen Simer 5. Answers come from this manual, with the pages they are based on.

Simer 5 Maintenance Schedule

Regularly (based on water hardness)
Clean the pump and inlet strainer

Clean the pump regularly depending on water hardness to prevent seal damage. Clean the inlet strainer to ensure maximum performance.

Every 1000 operating hours
Change the oil

Perform an oil change after every 1000 hours of operation. Fill the oil chamber with a maximum of 200 ml; overfilling damages the pump.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Simer 5?

Yes No

Frequently Asked Questions

A

The pump is effective starting from water levels of 5 mm and can drain surfaces down to a residual level of 2 mm.

Is this answer helpful?

A

No, the Simer pump is not suitable for saline media or water containing fish, as it may cause damage or harm aquatic life.

Is this answer helpful?

A

The oil should be changed after every 1000 hours of operation to ensure the pump continues to function correctly.

Is this answer helpful?

A

You should not run the pump dry for more than 20 minutes. Extended dry running can damage the internal components.

Is this answer helpful?

A

The pump must be connected to a socket protected by at least a 10 A slow-blow fuse and a 30 mA RCD safety switch.

Is this answer helpful?

A

Always lift the pump using the carrying handle. Never lift it by the power cable, and lower it into place using a rope or chain.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Can drain water down to a residual level of just 2 mm
  • Stepped hose connector fits 1/2", 3/4", and 1" hoses easily
  • Built-in thermal protection prevents motor damage from overheating
  • Effective for various applications like draining cellars, pools, and roofs
VS

Disadvantages

  • Not suitable for pumping saline water or water from fish ponds
  • Requires regular oil changes every 1000 operating hours
  • Cannot be permanently connected to building drainage systems
  • Must be kept away from freezing conditions when in use
M: QW-35-FL

Product Specification

Power

190W

Flow rate

1135.8 gpm

Head height

19.69 ft

Pressure connection

1 1/4"

Hose connection

1/2", 3/4", 1"

Features

no tank, IP68, overload protection

Cable length

32.81 ft

Weight

11.02 lbs

M: QW-35-FL

Product Description

Jung Pumpen Simer 5 Electric Submersible Pump 10m - Read, Download & Print Free

The Jung Pumpen Simer 5 Electric Submersible Pump is a versatile and robust solution designed for efficient water management in various environments. Whether you are dealing with flooded basements, draining roof surfaces, or clearing puddles on sports courts, this pump delivers reliable performance. It is engineered to handle water levels as low as 5 mm, ensuring that residual water can be reduced to just 2 mm without the need for additional accessories. This capability makes it an ideal choice for homeowners and professionals alike who require precise drainage control.

Constructed with durability in mind, the Simer 5 features a stepped hose connector compatible with 1/2", 3/4", and 1" hoses, allowing for immediate operation once connected. The automatic vent valve at the base ensures smooth operation by preventing air locks, although users must keep this area clean to maintain optimal function. The pump is equipped with a winding thermostat that automatically shuts off the unit if temperatures become dangerously high due to dry running or overload, protecting the motor from irreversible damage.

Safety is paramount with this device. It should only be connected to properly installed sockets protected by a 10 A fuse and a residual current device (RCD) of 30 mA. Users must never operate the pump while a person is in the water. Additionally, the pump is not suitable for saline media or fish ponds, and the pumped medium temperature must not exceed 60°C. Regular maintenance, including cleaning the inlet strainer and changing the oil every 1000 hours, is essential to prolong the life of the equipment.

Important Notes

  • Always disconnect power before performing any maintenance.
  • Do not run the pump dry for more than 20 minutes.
  • Lift the pump by the handle, never by the cable.
  • Ensure the work area is free of toxic gases before use.
M: QW-35-FL