INSTALLATION
The pump must be installed as shown in the examples. For in-
stallations in accordance with EN 12056-4, the pressure pipe
must be laid in a loop above the local backow level and pro-
tected with a non-return valve in accordance with EN 12050-4.
A correspondingly larger diameter pipe should be used for
longer pressure pipelines to avoid pipe friction losses.
The MultiDrain pumps have both a horizontal and a vertical
discharge branch. The branch that is not used must be sealed
with the plug. During operation, the pump is automatically ven-
tilated via this plug.
In contrast to pumps with built-in level control, the ON and OFF
switching heights of pumps without built-in level control are
variable by the use of a separate level control.
NOTICE! If the pump is malfunctioning, part of the contents of
the oil reservoir could escape into the pumping medium.
Dimensions of sump
Single installation with pump base: 40 x 50 cm
Single installation with guide rail system: 40 x 70 cm
Duplex installation: 70 x 70 cm
Example of single installation with guide rail system
Installation: Fix the coupling base rmly to the oor of the col-
lection chamber using wall plugs and then mount the guide rail.
Next, install the pressure pipe including the necessary ttings,
such as the non-return valve and shut-off valves.
Finally, t the pump with the screwed-on coupling catch onto
the guide rail and lower it into place using a chain xed to the
handle.
Example of duplex installation
NOTICE! The oats of the level control and alarm system are
installed so that they are freely movable but not under the in-
let. Please observe the minimum distances. The controls must
only be installed in a dry and well ventilated room!
MAINTENANCE
Maintenance and inspection of this product must be carried
out in accordance with EN 12056-4.
To ensure continued reliability of service, we recommend that
you take out a service contract.
DANGER!
Before carrying out any work: Disconnect the pump and the
control unit from the mains power supply and take action to en-
sure that no one else can reconnect them to the power supply.
WARNING!
Check the plug and the mains cable for signs of mechanical
and chemical damage. Damaged or kinked cables must be re-
placed by the manufacturer.
NOTICE! When using a chain to lift the pump, please observe
the relevant national regulations regarding accident preventi-
on. Lifting gear must be checked regularly by an expert in ac-
cordance with the legal regulations.
Cleaning
The inlet strainer prevents coarse dirt from entering the pump.
Regular cleaning of the oat and the foot strainer ensures opti-
mum performance and operation.
If the impeller needs to be cleaned due to blocking or clogging,
remove the screws on the underside of the pump and then re-
move the foot strainer.
Check and clean the ventilation hole in the sealing plug that is
tted in the unused discharge branch.
Tightening torque M
A
for A2 screw materials
for M 6 M
A
= 8 Nm,
for M 8 M
A
= 20 Nm,
for M 10 M
A
= 40 Nm,
for M 12 M
A
= 70 Nm,
for foot strainer M
A
= 3 Nm.
9

Chat with your Jung Pumpen Multidrain UV 620-1 manual using AI

Get instant AI answers from your Jung Pumpen Multidrain UV 620-1 manual

Ask anything about the Jung Pumpen Multidrain UV 620-1. Answers come from this manual, with the pages they are based on.

Multidrain UV 620-1 Maintenance Schedule

Regularly
Clean the inlet strainer and float

Regular cleaning of the foot strainer and float prevents coarse dirt entry and ensures maximum pump performance.

Regularly
Check and clean ventilation hole in sealing plug

Inspect and clean the ventilation hole in the sealing plug of the unused discharge branch to ensure proper automatic venting.

Regularly
Inspect lifting gear for safety compliance

Lifting gear used to lower or raise the pump must be checked regularly by an expert in accordance with legal regulations.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Multidrain UV 620-1?

Yes No

Frequently Asked Questions

A

The pump is designed to transport wastewater containing admixtures with a maximum grain size of 10 millimeters.

Is this answer helpful?

A

No, electrical work must only be performed by a qualified electrician to ensure safety and compliance with local regulations.

Is this answer helpful?

A

Running the pump dry can cause immediate motor damage. The built-in thermostat will shut it down, but prevention is key to avoiding repairs.

Is this answer helpful?

A

Check the startup jolt; it should oppose the arrow on the motor housing. Loud noises or low performance indicate wrong rotation requiring phase swap.

Is this answer helpful?

A

Yes, when stored in dry conditions, the pump is frost-resistant down to minus 20 degrees Celsius, but it must not freeze while installed in water.

Is this answer helpful?

A

The pump must be connected to a circuit protected by a 16 A slow-blow fuse and a residual current device with a trip current of 30 mA.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Handles solids up to 10 mm grain size effectively
  • Automatic thermal protection prevents motor burnout
  • Flexible discharge options with horizontal and vertical ports
  • Continuous operation possible with submerged yellow ring
  • Compact design fits standard sump pit dimensions
VS

Disadvantages

  • Requires professional electrical installation only
  • Cannot run dry without risking severe motor damage
  • Must be disconnected before clearing blockages due to auto-restart risk
  • Free cable end requires separate approved connector purchase
  • Limited to media temperatures below 40 degrees Celsius
M: QW-35-FL

Product Specification

Power

2400 W

Flow rate

9514 gph

Head height

60.7 ft

Pressure connection

2"

Features

without tank, IP68

Cable length

32.8 ft

Weight

50.71 lbs

M: QW-35-FL

Product Description

Jung Pumpen Multidrain UV 620-1: Reliable Sewage Handling

The Jung Pumpen Multidrain UV 620-1 Electro Submersible Sewage Pump is a robust solution designed for demanding drainage applications. This submersible pump belongs to the MultiDrain series, which is specifically engineered to handle wastewater, rainwater, groundwater, seepage water, and drainage water containing solid particles up to 10 mm in size. Its versatility makes it an ideal choice for residential basements, commercial buildings, and industrial sites where efficient water management is critical.

Constructed with durability in mind, this pump features a compact design that allows for easy installation in sump pits of various dimensions. The unit supports both horizontal and vertical discharge options, providing flexibility during setup. A key feature of the UV 620-1 is its ability to operate continuously as long as the yellow float ring remains submerged, ensuring consistent performance without interruption. However, running the pump dry must be strictly avoided to prevent motor damage, as the device includes a winding thermostat that automatically shuts off the unit if temperatures become dangerously high due to overload or dry running.

Safety is paramount in the design of the Jung Pumpen Multidrain UV 620-1. The pump is equipped with a thermal cut-off switch that protects the motor from overheating. It is crucial to disconnect the power supply before attempting to clear any blockages, as the pump may restart automatically once it cools down. Electrical connections must be performed by qualified professionals using circuits protected by at least a 16 A slow-blow fuse and a residual current device (RCD) rated at 30 mA. The pump handles media temperatures up to 40°C and can be stored in dry conditions at temperatures as low as -20°C without freezing.

Maintenance is straightforward but essential for longevity. Regular cleaning of the foot strainer prevents clogging and ensures optimal pumping efficiency. If the impeller becomes blocked by solids or fibrous matter, the strainer can be removed for inspection and cleaning. The pump also features a self-venting mechanism via a plug on the unused discharge port, simplifying operation. Whether used in a single installation with a guide rail system or as part of a duplex setup, the UV 620-1 delivers reliable performance when installed according to safety guidelines.

Important Notes

  • Always lift the pump by the handle, never by the power cable.
  • Ensure the pressure pipe is looped above the backflow level to prevent sewage backup.
  • Use only original spare parts to maintain warranty and safety standards.
  • Check rotational direction upon installation; incorrect rotation reduces efficiency and increases noise.