Important notice beforehand:
Please don’t forget to buy a new JBL PROFLORA CO
2
pH SENSOR SET!
To guarantee you the highest reliability when using the included JBL PROFLORA CO₂ CONTROL, this control unit comes without a pH sensor� When
purchasing the unit make sure to also purchase a new pH SENSOR SET� Your specialist pet shop will have one in stock for you�
Dear customer,
Choosing to buy this highly modern JBL PROFLORA CO₂ CONTROL was an excellent decision� The latest measurement and control technology mea
-
sures the pH value and temperature and regulates the pH value and supply of CO₂ reliably and fully automatically
� This ensures luxuriant plant growth
and healthy fish� JBL PROFLORA CO₂ CONTROL has a coloured touch display for easy operation as well as a whole range of useful features never
before incorporated in equipment of this class� A simple multi-lingual menu guides you safely through all the menu points� The device is designed
for the control of the external solenoid valve JBL PROFLORA CO₂ VALVE� The complete equipment runs on low voltage (12V), providing the highest
possible safety�
Safety instructions
1� Operation only with solenoid valves JBL PROFLORA CO
2
VALVE or CO
2
sets containing such a valve�
2� Follow the safety instructions for handling CO
2
� These can be found on the CO₂ pressurised gas cylinders�
3� Children must be supervised to ensure that they do not play with the appliance and its power supply unit�
4� The appliance must not be used for any purpose other than that described in these instructions for use�
5� Do not operate or store the unit in places where there is a risk of frost�
6� Appliance may only be used indoors�
7� Appliance may only be used in a dry environment�
Disposal: Do not dispose of this device and the power unit in the normal household waste� Please follow your local disposal regulations for electrical
equipment�
1. Parts and description
1 Top-hat rail
2 Screws with dowels (2 x each)
3 Power supply unit 12 V DC
4 JBL PROFLORA CO₂ CONTROL measuring and display unit
5 Coloured touch display
6 Input socket for power supply 12 V DC
7 Connection for temperature sensor
8 BNC connection for pH sensor
9 12 V DC output socket for connecting cable for solenoid valve
10 Temperature sensor
10a Suction holder for temperature sensor (2 x)
11 Connecting cable for solenoid valve
12 Holder for calibration cuvettes
13 JBL PROFLORA pH SENSOR SET (please purchase separately!)
2. Installation
The illustration shows a typical installation example�
E
4
8 9 9
E
D
3
D
C
4
5
6
CB
1
1
B
2
!
1 Measuring and control device JBL PROFLORA CO₂ CONTROL
2 Power supply unit
3 pH sensor
4 Temperature sensor
5 CO2 reactor JBL PROFLORA CO₂ TAIFUN SPIRAL
6 Bubble counter with integrated backflow protection JBL PROFLORA CO₂ TAIFUN COUNT SAFE
7 Connecting cable for solenoid valve
8 Solenoid valve JBL PROFLORA CO₂ VALVE
9 Special CO₂ hose
2.1 Mounting the JBL PROFLORA CO₂ CONTROL measurement and control device
First attach the top-hat rail in a horizontal position to the desired position on the wall near the aquarium, using the two screws supplied� Hang the
rear bracket of the device on the upper edge of the rail and click it into place by applying slight pressure from the front� (It can easily be removed
from the top-hat rail at any time by sliding it sideways�)
2.2 Installing the sensors and connecting to the power supply
Connect the plug of the pH sensor and the temperature sensor to the corresponding connections on the appliance� Do not install the two sensors in
the aquarium until calibration is complete� Connect the JBL PROFLORA CO₂ VALVE solenoid valve provided to the measuring and control device
using the solenoid valve connection cable� The connection on the device is marked “valve”� Any previous power supply unit for the solenoid valve is
no longer needed� All the connectors and plugs on the device and all the sensors and cables are designed in such a way that an incorrect connection
is not possible� Plug the universal power supply unit into a nearby power socket and insert the plug on the cable into the socket labelled 12 DC on
the device�
UKUK
16 17

Chat with your JBL Aquaristic ProFlora CO2 Control manual using AI

Get instant AI answers from your JBL Aquaristic ProFlora CO2 Control manual

Ask anything about the JBL Aquaristic ProFlora CO2 Control. Answers come from this manual, with the pages they are based on.

ProFlora CO2 Control Maintenance Schedule

Remind me when maintenance is due
Monthly
Calibrate the pH sensor

Perform a two-point calibration using buffer solutions pH 7.00 and then pH 4.00. The device recommends intervals of 30, 45, or 60 days, with 30 days being the factory default.

As needed / When dirty
Clean the sensor tip

Remove dirt from the glass sensor tip by dabbing it gently with a soft cloth. Never rub vigorously to avoid damaging the sensitive tip.

Show in the manual (page 12)
Regularly
Check sensor placement

Regularly check that the sensor is fully submerged in water. If pulled out or if water level drops, measurements will be incorrect and fish may be endangered.

Show in the manual (page 12)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend ProFlora CO2 Control?

Yes No

Frequently Asked Questions

A

The device recommends calibration every thirty days to maintain high accuracy. The timer resets upon successful completion. Frequent calibration compensates for natural sensor aging processes.

Is this answer helpful?

A

Auto pH calculates the optimal pH set point based on the carbonate hardness input. It uses a standard CO2 value of 22.5 mg/l to determine safe targets for plants and fish.

Is this answer helpful?

A

No, the pH sensor is sold separately as part of a dedicated kit. Buyers must acquire the JBL PROFLORA CO2 pH SENSOR SET independently for full functionality.

Is this answer helpful?

A

Yes, it can be used with calcium reactors in marine water applications. It monitors pH inside the reactor to regulate CO2 dosing for effective lime dissolution.

Is this answer helpful?

A

You can enable key lock via the settings menu. Enter a four-digit password or use the master password 7442 to unlock the interface after locking.

Is this answer helpful?

A

Default alarms trigger if pH deviates plus or minus 1.00 or temperature goes outside 20 to 30 degrees Celsius. These limits are adjustable through the menu.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Automatic pH regulation based on entered carbonate hardness reduces manual effort significantly.
  • Colorful touch display allows intuitive menu navigation and status monitoring easily.
  • Low voltage operation ensures maximum user safety during installation and daily use.
  • Multi-language support includes nine options catering to diverse international markets globally.
  • Comprehensive alarm system notifies owners of critical deviations via visual and audio signals.
VS

Disadvantages

  • pH sensor must be purchased separately which adds initial cost to the setup.
  • Regular calibration every 30 days is required to maintain measurement accuracy consistently.
  • Sensors degrade over time requiring replacement typically every two years of usage.
  • Manual installation of rail and sensors requires basic technical knowledge and tools.
  • Power outage interruptions reset calibration timers leading to temporary tracking issues.
M: QW-35-FL

Product Specification

Category

Water Treatment, Water Parameters

Type

Controller for CO2 Regulator with Solenoid Valve (BNC Connection for pH Electrode, Thermometer, Touchscreen)

Suitability

Freshwater, Aquarium

Dimensions

3.50x2.64x0.98 in (WxHxD)

Weight

1.01 lbs

M: QW-35-FL

Product Description

JBL Pro Flora CO2 Control Manual Overview

Maintaining a healthy aquarium environment requires precise monitoring of carbon dioxide levels to support aquatic vegetation. The JBL PROFLORA CO2 CONTROL system offers a sophisticated solution for freshwater planted tanks globally. When you consult the detailed JBL Pro Flora CO2 Control Manual, you discover a device designed to automate plant growth conditions effectively. This digital measuring and control unit monitors pH and temperature continuously using advanced sensors. It regulates CO2 supply to ensure plants thrive while keeping fish completely safe from harmful gas spikes. Installation is straightforward when following the guide provided by the manufacturer carefully. Mount the rail near the aquarium and connect the sensors securely to ports. The device features a colorful touch display for easy navigation through various menus. You can choose from nine languages including English and German for user convenience. This ensures consistent performance for all users regardless of experience level.

Key Features and Functionality

One standout feature is the Auto pH function which simplifies complex calculations. By entering your carbonate hardness value, the device calculates the optimal target pH automatically based on internal algorithms. This prevents dangerous fluctuations that could harm aquatic life significantly over time. The manual highlights safety protocols extensively throughout its pages regarding electrical safety. Operating on low voltage ensures user protection against potential electrical hazards during maintenance. It includes alarm functions for pH and temperature deviations which are fully configurable by the owner. If levels go outside set limits, visual and audio alerts notify the owner immediately through flashing symbols.

Maintenance and Care

Regular calibration is essential for accuracy and reliability over time within the ecosystem. The device guides users through a two-point calibration process using buffer solutions safely provided. Remember that the pH sensor is sold separately and must be replaced periodically as it ages over time consistently. The average service life is approximately twenty-four months depending on specific care routines taken. Additional settings allow customization of hysteresis and valve operation modes for specific needs. Users can lock the interface to prevent accidental changes via a four digit password system. Maintenance involves cleaning the surface gently with a damp cloth avoiding immersion. Whether you manage a lush planted tank or experiment with aquascaping this equipment provides reliable performance consistently. The system works with external solenoid valves specifically designed for this application perfectly. Adhering to the instructions found in the documentation ensures longevity and precision for many years. This comprehensive approach helps hobbyists achieve vibrant plant growth without constant manual intervention required daily. The technology bridges the gap between simple bubble counters and professional automation systems found in large facilities. Furthermore it supports use in calcification reactors for marine water applications efficiently allowing carbonate release.

M: QW-35-FL

© Copyright 2026 Manual.ly