Each of the six channels can handle up to 16A at 230V AC1. However, the sum of all currents across all six channels must not exceed 68A to ensure safe operation.
Is this answer helpful?
Yes, you can control the outputs manually using the local push-buttons when the Auto/Manu switch is set to Manual position. In Auto mode, only KNX bus commands are accepted.
Is this answer helpful?
Yes, the actuator supports various LED loads up to 200W per channel at 230V. It also handles fluorescent tubes with electronic ballasts and conventional transformers effectively.
Is this answer helpful?
Configuration is done using ETS application software. You must set the switch to Auto mode to download parameters. Physical addressing is performed using the lighted push-button.
Is this answer helpful?
If incompatible application software is loaded, the state indicators will continuously flicker after powering on or downloading. This indicates a configuration error that needs correction.
Is this answer helpful?
Installation requires mounting on a DIN rail and connecting wires between 0.75mm² and 2.5mm². Due to safety regulations, only qualified electricians should perform the installation.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Six independent channels allow versatile control of multiple electrical loads simultaneously
- Integrated current detection enables real-time energy monitoring and fault identification
- Manual override capability provides local control even during network outages
- Compact 6TE design saves space in distribution boards while maintaining high capacity
- Visual status LEDs offer instant feedback on relay states and bus connectivity
Disadvantages
- Requires professional installation by a qualified electrician due to high voltage risks
- Maximum total current limit of 68A restricts usage in very high-load industrial applications
- Local buttons become inactive in Auto mode limiting manual access without reconfiguration
- No built-in surge protection beyond standard category III limits
- Configuration requires specific ETS software knowledge which may have a learning curve
Product Specification
Type
Actor
Standard
KNX
Function
Switch actor (on/off)
Topology
Bus
Features
IP20, IP30, IK04
Product Description
Hager KNX Switch Actuator 6/3-fold 16A C-Load with Current Detection
The Hager KNX Switch Actuator TYA606E is a robust solution for modern building automation systems, designed to seamlessly integrate electrical loads with the KNX bus. This 6-fold actuator features current detection capabilities, allowing for advanced monitoring and control of lighting and other electrical devices. With a compact 6TE width, it fits perfectly into standard DIN rail installations while offering powerful functionality.
This device supports six independent channels that can be controlled via the KNX bus or manually using local push-buttons when set to manual mode. The integrated state indicators provide immediate visual feedback on relay status, ensuring easy troubleshooting. The unit includes a physical addressing button for quick configuration and bus verification. It handles various load types including incandescent lamps, halogen lamps, electronic transformers, and LED systems, with a maximum switching capacity of 16A per channel.
Safety is paramount, as the device must be installed by qualified electricians adhering to SELV rules. The current monitoring function enables efficient energy visualization, threshold surveillance, and fault detection for wiring issues. Whether managing lighting in residential settings or complex commercial environments, this actuator delivers reliable performance with precise measurement accuracy within a 0.05A to 16A range.
Key Features
The actuator operates on a 30V SELV supply voltage and consumes minimal power on the KNX bus. Its design ensures compatibility with ETS application software for lighting and shutter configurations. Users can switch between automatic bus control and local manual operation effortlessly. The device withstands harsh environmental conditions with an operating temperature range from -5°C to +45°C and offers IP20 protection for indoor use.
Important Notes
Always ensure the total current across all six channels does not exceed 68A. Do not exceed the maximum permissible load per device to prevent damage or fire hazards. Regular maintenance and adherence to local installation standards are crucial for optimal safety and longevity.