d. Electrical bonding : consideration shoud be given to bonding all metal objects in the surrounding area. However,
metal objects connected to the workpiece increase the riskof electric shock if the operator touches both these metal
elements and the electrode. It is necessary to insulate the operator from such metal objects.
e. Earthing of the welded part : When the part is not earthed because for electrical safety reasons or because of its
size and its location (which is the case with ship hulls or metallic building structures), the earthing of the part can, in
some cases but not systematically, reduce emissions. It is preferable to avoid the earthing of parts that could increase
the risk of injury to the users or damage other electrical equipments. If necessary, it is appropriate that the earthing
of the part is done directly, but in some countries that do not allow such a direct connection, it is appropriate that the
connection is made with a capacitor selected according to national regulations.
f. Protection and plating : The selective protection and plating of other cables and devices in the area can reduce
perturbation issues. The protection of the entire welding area can be considered for specic situations.
TRANSPORT AND TRANSIT OF THE MACHINE
The machine is equipped with a handle to facilitate transport. Be careful not to underestimate the
machine’s weight. The handle cannot be used to hang the machine from other equipment.
Do not use the cables or torch to lift or move the machine. The welding equipment must be moved in
an upright position.
. Transportation standards are different.
INSTALLATION
Rules to follow:
• Put the machine on the oor (maximum incline of 10°.)
• Ensure the work area has sufcient ventillation for welding, and that there is easy access to the control panel.
• The machine must be placed in a sheltered area away from rain or direct sunlight.
• The machine must not be used in an area with metallic dust.
• The machine benets from an IP21 protection index, which means:
- Protection against acess to dangerous parts from solid bodies of a ≥12.5mm diameter and,
- Protection against vertically falling water droplets
The manufacturer does not incur any responsibility regarding damage to both objects and persons that
result from an incorrect and/or dangerous use of the machine .
MAINTENANCE / RECOMMENDATIONS
• Maintenance should only be carried out by a qualied person.
• Ensure the machine is unplugged, and that the inside fan has stopped before carrying out maintenance work.
Caution - High Voltage and dangerous Current levels can be present inside the machine.
• Remove the casing 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical
connections checked by a qualied person, with an insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced
by the manufacturer, its after sales service or an equally qualied person to prevent danger.
• Ensure the ventilation holes of the device are not blocked to allow adequate air circulation.
• Do not use this equipment to thaw pipes, to charge batteries, or to start any engine.
• The power cables, extension cords and welding must be fully unwound in order to prevent overheating.
INSTALLATION – PRODUCT OPERATION
Only qualied personnel authorized by the manufacturer should perform the installation of the welding equipment.
During set up, the operator must ensure that the machine is unplugged. Connecting generators in a series or a parallel
circuit is forbidden.
HARDWARE DESCRIPTION
The 80P, 130P, 160P, 200P are Inverter technology based welding machines, portable, single phase, fan cooled, for
electrode welding (MMA) in direct current output(DC). These machines can weld all types of electrodes : rutile, basic/
low hydrogen (except 80P), stainless and cast iron. They’re protected to work with generators (230 V +- 15%).

Chat with your GYS GYSMI 80P manual using AI

Get instant AI answers from your GYS GYSMI 80P manual

Ask anything about the GYS GYSMI 80P. Answers come from this manual, with the pages they are based on.

GYSMI 80P Maintenance Schedule

Remind me when maintenance is due
Every 4 months
Remove casing and clean dust

Remove the casing 2 or 3 times a year to remove excess dust using an air blower.

Show in the manual (page 10)
Every 4 months
Check electrical connections

Have a qualified person check the tightness of electrical connections with an insulated tool while cleaning.

Show in the manual (page 10)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend GYSMI 80P?

Yes No
0
User Pic

Novella Ledner

8 months ago

Does the welding arc stay stable and the welding power stay constant during operation, or is it likely to fluctuate?

0
User Pic

Manual.ly

8 months ago

Based on customer testing and product behavior, the arc stability is designed to remain consistent, so you should see a steady arc and reliable performance during normal welding. One reviewer reported constant welding power and perfect arc stability during their test, matching the expected results when using the recommended settings and proper setup. For best results, ensure you select the correct process and parameters for your material and electrode/wire, use suitable cables and a secure earth connection, and keep within the device rating (duty cycle) during longer work sessions.

M: OA-GPT-5-NAN
M: OA-GPT-5-NAN

Product Specification

Power

3 kW (230 V)

Open circuit voltage

85 V

Control range

10-80 A (MMA)

Electrodes

0.06-0.10 in (MMA)

Dimensions

5.51x9.06x3.94 in (HxWxD)

Weight

5.51 lb