103616b9e9f0af57882f299a59434b5719ee page 12
32
Mandatory
1. Should any of the following conditions occur, turn off the machine immediately
(electrical shock, sparks, or smoke may occur):
-Strange noises or vibrations during operation.
-Product is unusually hot, or has a burnt odor.
2. Please clean the plug regularly
If there is dust or moisture on the plug it could damage it. This may result in a fire.
-Unplug the power cord, and wipe it with a dry cloth.
-Unplug the power cord if the appliance is not used for a long period of time.
3. Before electrical maintenance, make sure to unplug the device.
-The product may suddenly turn on, leading to electrical shock or injury.
4. Please plug the power cord securely into the power outlet. If the plug is not
securely seated, this may cause overheating which may lead to electrical shock
and even fire.
-Do not use a damaged plug or loose power outlet.
220V~
5A
5. Please unplug the cord using the plug insulator.
-Pulling the power cord to unplug it may cause damage to the
power cord, electrical shock, short circuit, or fire.
6. Should any of the following circumstances arise, please turn off the machine
power immediately and contact the service department:
-A switch does not work.
-Power cord or plug is unusually hot.
-You detect an abnormal sound or vibration.
-Any other abnormalities or malfunctions.
7. To prevent the hazard of electrical shock, only trained professionals should
disassemble the machine.
√
×
31
7. This product cannot
replace normal
ventilation equipment,
vacuum cleaners, or
kitchen fans.
8. Please do not use this
product near gas
appliances, heating
appliances, or stoves.
9. Do not use this
product in a humid or
hot environment, such
as the shower,
restroom, or kitchen.
10. Make sure the remote is placed somewhere
children cannot reach to avoid unintended damage.
11.The two arches at both sides of the operation panel
are not handles and cannot be pulled. The handles
are at both sides of the purifier body.
12.Do not place this machine up-side-down, because there is a liquid
humidification device in it.
13.Do not place in the following locations:
-Unstable places: this may cause the product to topple or fall down. This may
lead to injury, electrical leakage, or fire.
-Hot or humid places, such as the shower: this may result in electrical shock or
fire due to electrical leakage.
-Places like the kitchen that emit fumes.
14.Do not use the air purifier in a room that is using an incense-type insect killer.
-Chemical residue may accumulate in the machine and then be released,
causing harm to physical health.
-After using insect killer or mosquito coils, allow the room to be fully
ventilated before using the air purifier.
Fresh Air Healthy Life
ENG
(*)Competent qualified electrician: after-sales department of the producer or
importer or any person who is qualified, approved and competent to perform this
kind of repairs in order to avoid all danger. In case of need you should return the
appliance to this electrician (www.ggv-service.de).

Chat with your Gutfels LR 67013 manual using AI

Get instant AI answers from your Gutfels LR 67013 manual

Ask anything about the Gutfels LR 67013. Answers come from this manual, with the pages they are based on.

LR 67013 Maintenance Schedule

Remind me when maintenance is due
Every 2 months
Clean cellular activated carbon and cold catalyst filters

Vacuum dust from the front. Place in a ventilated area to dissipate gases. Do not use water or press too hard.

Show in the manual (page 19)
Every 2 months
Maintain antibacterial cotton and HEPA filters

Place in a ventilated area to allow harmful gases and germs to dissipate. Do not use water to clean these filters.

Show in the manual (page 19)
Every 2 months
Clean the particulate sensor lens

Unplug the device. Remove the sensor cover and wipe the lens with a dry cotton swab to remove dirt.

Show in the manual (page 19)
Every 6 months
Replace filters No. 2 and No. 3

Suggested period to replace filters #2 and #3 is 6 months based on the performance index table.

Show in the manual (page 12)
Every 2 years
Replace filter No. 1

Suggested period to replace filter #1 is 2 years based on the performance index table.

Show in the manual (page 12)
Twice per month
Clean the pre-filter

Clean the surface with a vacuum or wash with water. Allow to dry thoroughly before reinstalling.

Show in the manual (page 19)
Every 320 operating hours
Reset filter No. 1 cleaning reminder

After the indicator flashes every 320 hours, clean filter No. 1 and press the reset button for 5 seconds.

Show in the manual (page 15)
Every 1500 operating hours
Replace filters No. 2 and No. 3

The indicator stays on after 1500 hours. Replace filters No. 2 and No. 3, then press the reset button for 5 seconds.

Show in the manual (page 15)
Regularly
Clean the power plug

Wipe the plug with a dry cloth if dust or moisture is present to prevent fire hazards. Unplug before cleaning.

Show in the manual (page 18)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend LR 67013?

Yes No

Frequently Asked Questions

A

You should clean the pre-filter approximately twice a month using a vacuum cleaner or by washing it with water and letting it dry thoroughly.

Is this answer helpful?

A

No, do not use this product in the kitchen or other areas that emit fumes, as this can damage the unit and reduce its effectiveness.

Is this answer helpful?

A

Auto mode uses the sensor to automatically adjust fan speed based on air quality, while Compulsory mode lets you manually set the speed and choose which features like UV or ions are active.

Is this answer helpful?

A

After cleaning or replacing the filters, press and hold the Reset button for five seconds until the indicator light stops flashing.

Is this answer helpful?

A

No, the negative ion generator and UV sterilization are designed to purify air without creating harmful ozone or secondary pollution.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Multi-stage filtration including HEPA and cold catalyst for superior air cleaning
  • Integrated evaporative humidifier adds moisture to dry air
  • Smart auto-mode adjusts fan speed based on real-time PM2.5 sensor data
  • UV sterilization and negative ion technology effectively kill germs and settle dust
  • Includes remote control and child-lock safety feature for convenience
VS

Disadvantages

  • Requires regular cleaning of the pre-filter every two weeks
  • Specialized filters need replacement every six months to two years
  • Cannot be used near gas appliances or in extremely humid areas like showers
  • Remote control requires specific button cell batteries not included
  • Machine must be placed on the floor for optimal pollen and dust removal
M: QW-35-FL

Product Specification

Power

95W

Color

white, black

Recommended Room Size

up to 753 sq ft

Air Circulation

15860 cu ft/h

Water Tank Capacity

0.45 gal

Filtration

4-stage, HEPA filter, activated carbon filter, cold catalyst filter, water purification

Display

yes

Features

remote control, night mode, switchable ionization, switchable UV disinfection, air quality monitoring (dust, fine dust, pollen, bacteria)

Noise Level

18-55dB(A)

Dimensions

9x24x16 in (WxHxD)

Weight

23.81 lbs

M: QW-35-FL

Product Description

Experience Pure Air with the Gutfels LR 67013

Welcome to a new era of indoor comfort with the Gutfels LR 67013 Luftbefeuchter/Luftreiniger. This advanced appliance is designed to transform your living space by combining powerful air purification with effective humidification. Whether you suffer from allergies, live in a smoky environment, or simply desire fresher air, this unit offers a comprehensive solution.

The Gutfels LR 67013 utilizes a multi-stage filtration system that targets pollutants at every level. Starting with a washable pre-filter made of aluminum alloy, it captures large dust particles and pet dander. The process continues through a cold catalyst filter that safely breaks down harmful gases like formaldehyde without producing secondary pollution. A cellular activated carbon filter absorbs odors, while an antibacterial cotton filter and a high-efficiency HEPA filter work together to trap microscopic particles, bacteria, mold, and viruses as small as 0.3 microns.

Beyond filtration, the device features a sterilizing UV light that eliminates airborne bacteria and a negative ion generator that helps heavy pollutants settle out of the air naturally. For added comfort during dry seasons, the integrated evaporative humidifier releases moisture into the room automatically when water is added to the side tank. The unit also includes smart sensors that adjust fan speed based on real-time PM2.5 data, ensuring efficient operation whether in Auto, Night, or Manual modes. With its sleek design, remote control, and child-lock safety feature, the Gutfels LR 67013 is the perfect addition to any modern home seeking health and hygiene.

M: QW-35-FL

© Copyright 2026 Manual.ly