3.0 Installation
3.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should
have received the following items in the package:
The unit x 1
User manual x 1
USB Communication cable x 1
Current sharing cable (parallel model available)
Parallel communication cable (parallel model available)
Note: The Software CD is no longer provided, if necessary, please download it from the official website
www.ginverter.com
3.2 Preparation
Before connecting all wiring, please take off bottom cover by removing two screws as shown below.
3.3 Mounting the Unit
Consider the following points before selecting where to install:
Do not mount the inverter on flammable construction materials.
Mount on a solid surface
Install this inverter at eye level in order to allow the LCD
display to be read at all times.
The ambient temperature should be between 0°C and 55°C
to ensure optimal operation.
The recommended installation position is to be adhered to
the wall vertically.
Be sure to keep other objects and surfaces as shown in the
right diagram to guarantee sufficient heat dissipation and
to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR
OTHER NON-COMBUSTIBLE SURFACE NLY.
Install the unit by screwing three screws. It’s recommended to use M4 or M5 screws.

Chat with your Growatt SPF TL HVM manual using AI

Get instant AI answers from your Growatt SPF TL HVM manual

Ask anything about the Growatt SPF TL HVM. Answers come from this manual, with the pages they are based on.

SPF TL HVM Maintenance Schedule

Remind me when maintenance is due
Monthly
Perform battery equalization cycle

The manual recommends periodic battery equalization to reverse stratification and remove sulfate crystals. The default interval is set to 30 days in program 47.

Show in the manual (page 36)
Periodically
Inspect unit for damage

Before installation or during service, inspect the unit to ensure nothing inside the package or on the device is damaged.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend SPF TL HVM?

Yes No

Frequently Asked Questions

A

The inverter supports both lead-acid batteries (AGM and Flooded) and lithium-ion batteries. For lithium options, it requires connection to a compatible BMS via CAN or RS485 for full functionality.

Is this answer helpful?

A

Yes, the 4KVA and 5KVA models support parallel operation. You can connect up to six units in single-phase or configure them for three-phase systems to significantly increase total power output.

Is this answer helpful?

A

You can configure the priority using Program 01 on the LCD panel. Options include Solar First, Utility First, and SBU Priority, allowing you to decide whether solar, grid, or battery power takes precedence.

Is this answer helpful?

A

Yes, by installing an optional WiFi or GPRS module, you can monitor system status, view real-time data, and manage settings remotely through a mobile app or website.

Is this answer helpful?

A

The inverter will automatically switch to battery mode warning or shut down to protect the battery. You can adjust the cut-off voltage levels in the LCD settings to suit your specific battery type.

Is this answer helpful?

A

While basic tools are needed, all electrical wiring must be performed by qualified personnel. Proper torque wrenches are recommended for tightening battery terminals to ensure safety and prevent overheating.

Is this answer helpful?

A

It is recommended to enable the equalization function periodically, typically every 30 days as per default settings, to remove sulfate crystals and balance cell voltages, especially for flooded lead-acid batteries.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Integrates inverter, charger, and UPS functions in one compact unit
  • Supports both lead-acid and lithium batteries with BMS communication
  • Offers flexible power source priority settings for customized energy management
  • Enables parallel expansion for 4KVA and 5KVA models to increase capacity
  • Includes remote monitoring capabilities via optional WiFi or GPRS modules
VS

Disadvantages

  • Parallel installation requires additional hardware and complex wiring for 4KVA/5KVA models
  • Lithium battery setup necessitates specific BMS protocol matching which may require technical knowledge
  • Initial setup involves detailed configuration of multiple LCD programs for optimal performance
  • Requires qualified personnel for safe installation of high-voltage DC and AC connections
  • Some advanced features like three-phase parallel operation have strict phase synchronization requirements
M: QW-35-FL

Product Specification

Note

Prices may include 0% VAT rates for AT and DE

Type

Hybrid inverter, off-grid capable

MPP tracker count

1

Efficiency

93.00% max.

Input

Terminals

Output

Terminals

Interfaces

1x USB-B, 1x RS-485

Protection class

IP20

Ambient temperature

32°F to 131°F

M: QW-35-FL

Product Description

Growatt SPF TL HVM Manual: Your Guide to Off-Grid Solar Power

The Growatt SPF TL HVM series represents a significant leap in off-grid solar technology, designed for users seeking reliable backup power and efficient energy self-consumption. This multifunctional hybrid inverter integrates a high-frequency pure sine wave inverter, an MPPT solar charge controller, and a UPS module into a single compact unit. Whether you are powering a remote cabin or enhancing home energy independence, this device offers robust performance with rated powers ranging from 2KVA to 5KVA.

One of the standout features of the Growatt SPF TL HVM is its versatility in battery compatibility. It supports both lead-acid and lithium-ion batteries, allowing users to customize their system based on budget and longevity needs. The built-in communication capabilities enable seamless integration with Battery Management Systems (BMS) via CAN or RS485 protocols, ensuring optimal charging cycles and extended battery life. For larger energy demands, the 4KVA and 5KVA models offer optional parallel operation, letting you connect multiple units to scale your power output effortlessly.

Installation is streamlined with clear guidelines for mounting, wiring, and configuration. The unit features a user-friendly LCD display that provides real-time data on input voltage, output status, load percentage, and battery state of charge. Advanced settings allow you to prioritize power sources, choosing between solar-first, utility-first, or battery-first modes to suit your specific energy strategy. Safety is paramount, with comprehensive protections against overloads, short circuits, and extreme temperatures.

For those looking to monitor their system remotely, the Growatt SPF TL HVM supports plug-and-play WiFi or GPRS modules. This connectivity transforms how you interact with your solar setup, offering insights from anywhere in the world. From initial unpacking to final commissioning, understanding the nuances of this manual ensures your system operates at peak efficiency. By following the detailed procedures for AC, DC, and PV connections, you can build a resilient energy infrastructure capable of handling modern power challenges.

Key Notes

  • Always ensure proper grounding to prevent electric shock hazards.
  • Use recommended cable sizes to maintain system safety and efficiency.
  • Regular battery equalization helps prevent sulfation and extends lead-acid battery life.