The table below shows the effects of different levels of CO poisoning on the
body;
Warning: The device cannot warn against the chronic effects of exposure to carbon monoxide or protect
individuals who are at specific risk.
NOTE: If you recognise any of the above symptoms consult your Doctor immediately.
NOTE: Young children, elderly and pets are more susceptible to the dangers of CO.
NOTE:
Your GLORIA alarm is designed to detect CO gas. It is not designed to detect other gas such as natural gas.
NOTE: This product is intended for use in ordinary family homes. It is not designed to measure compliance with
occupational safety and the HSE.
NOTE: Individuals with certain specific medical conditions may need an alarm that operates below 30ppm. If
this applies consult your Doctor.
IMPORTANT: Ensure that all family members are familiar with the symptoms of CO poisoning and how your
alarm works.
To be safe, know the possible sources of CO in your home, caravan, motor home, or boat. Keep fuel burn
ing
appliances and their chimneys and vents in good working condition. Learn the early symptoms of exposure, and
if you suspect CO poisoning, move outside to fresh air and get emergency help. Your first line of defence is an
annual inspection and regular maintenance of your appliances. Contact a licensed contractor or call your local
utility company for assistance.
In rented properties your Landlord (or Council/ Housing Association), will have an Emergency Response
phone number, and be lia
ble for the regular maintenance of their combustion appliances(Gas/LPG/Oil/
Solid Fuel).
PParts per Million (PPM)
of CO
TiEffects on Adults
100 Slight headache, nausea, fatigue (flu-like symptoms)
200 Dizziness and headache within 2 – 3 hours
400
Nausea, frontal headache, drowsiness, confusion and rapid heart rate. Risk to life after
over 3 hours of exposure
800 Severe headaches, convulsions, vital organ failures. Death possible within 2 – 3 hours
PParts per Million (PPM)
of CO
TiEffects on Adults
100 Slight headache, nausea, fatigue (flu-like symptoms)
200 Dizziness and headache within 2 – 3 hours
400
Nausea, frontal headache, drowsiness, confusion and rapid heart rate. Risk to life after
over 3 hours of exposure
800 Severe headaches, convulsions, vital organ failures. Death possible within 2 – 3 hours

Chat with your Gloria KO2D manual using AI

Get instant AI answers from your Gloria KO2D manual

Ask anything about the Gloria KO2D. Answers come from this manual, with the pages they are based on.

KO2D Maintenance Schedule

Weekly
Test the alarm

Press and release the test button to verify proper operation of the circuitry, horn, and batteries.

Show in the manual (page 14)
Yearly
Clean the alarm

Use compressed air or a vacuum on openings and wipe the outside with a damp cloth. Do not use detergents.

Show in the manual (page 20)
Yearly
Inspect fuel-burning appliances

Ensure annual inspection and regular maintenance of combustion appliances and their chimneys/vents.

Show in the manual (page 18)
Every 10 years
Replace the alarm unit

The manufacturer recommends replacing the alarm ten years from the install date.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend KO2D?

Yes No

Frequently Asked Questions

A

The Gloria KO2D is designed to detect carbon monoxide produced by combustion sources, such as boilers, gas fires, stoves, fireplaces, heaters, blocked flues, and vehicle exhaust. It does not detect smoke, flames, natural gas, or other gases.

Is this answer helpful?

A

The display shows detected carbon monoxide concentration in ppm. It can also show status messages: "Lb" for low battery, "Err" for a fault, and "End" when the detector has reached the end of its service life.

Is this answer helpful?

A

Move everyone to fresh air immediately. Open doors and windows if it is safe, turn off combustion appliances where possible, and do not re-enter if the alarm continues. Seek medical help for symptoms and contact emergency or qualified service personnel.

Is this answer helpful?

A

Test the detector weekly and after returning from an extended absence. Press and release the Test/Reset button. If the alarm does not sound correctly, or sounds weak or irregular, replace the detector.

Is this answer helpful?

A

Install it in rooms with fuel-burning appliances, 1 to 3 meters from the potential CO source. Add detectors in sleeping areas and on every home level. Place it at breathing height where appropriate and keep it accessible for testing.

Is this answer helpful?

A

Avoid garages, bathrooms, dusty spaces, insect-prone areas, strong airflow, direct sunlight, and locations near vents, windows, doors, cookers, or heating appliances. Do not place it where curtains, furniture, or other objects can block its openings.

Is this answer helpful?

A

Replace the detector ten years after installation. The display shows "End" and the yellow LED and audible alerts indicate end of life. Replace low batteries promptly and replace the entire detector if a persistent fault message appears.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Digital display shows carbon monoxide readings in ppm for quick status checks.
  • Peak-value memory records the highest CO level measured since the last reset.
  • 85 dB(A) audible alarm, red LED warning, and clear four-beep alarm pattern improve awareness.
  • Suitable for homes, caravans, motorhomes, and boats, with two AA battery operation.
  • Test/Reset control supports weekly checks and can acknowledge selected warning notifications.
VS

Disadvantages

  • Detects carbon monoxide only and does not detect smoke, fire, natural gas, or other toxic gases.
  • Requires regular battery replacement and weekly manual testing for dependable operation.
  • Digital readings may vary with environmental conditions and sensor tolerances.
  • Not intended for industrial compliance monitoring or hazardous-area installation.
  • Must be replaced after ten years, even if it appears to remain functional.
M: gpt-5.6-terra

Product Specification

Type

Gas detector

Sensors

Carbon monoxide (CO)

Alarm zones

1

Standard

N/A

Power supply

Battery (1 x AA), permanently installed

Operating temperature

14°F to 113°F

Dimensions

2.83 x 4.57 x 1.57 in

Weight

5.86 oz

Special features

Siren (85 dBA)

M: gpt-5.6-terra

Product Description

Gloria KO2D Carbon Monoxide Detector Manual

The Gloria KO2D Carbon Monoxide Detector is a battery-powered safety alarm designed to help households identify dangerous carbon monoxide levels from fuel-burning appliances. Carbon monoxide is colorless, odorless, and tasteless, making reliable detection especially important around boilers, stoves, fireplaces, portable heaters, and attached garages. This compact detector is suitable for homes, apartments, caravans, motorhomes, and boats.

Clear readings and practical alerts

A key advantage of the KO2D model is its digital display, which shows detected CO concentrations in parts per million (ppm). It also includes a peak-value memory, allowing users to review the highest recorded reading between 11 and 999 ppm since the memory was reset. This feature can be useful when investigating intermittent exposure or checking conditions after a suspected event.

When carbon monoxide is detected, the alarm uses a distinct pattern of four rapid beeps repeated every five seconds. A red LED flashes in sync with the audible warning, while the display shows the current CO reading. The alarm is rated at 85 dB(A) at three meters, providing a strong warning signal for occupied living spaces.

Everyday operation

The detector operates on two AA batteries and includes a Test/Reset button for regular function checks. Weekly testing is recommended to verify the alarm, electronics, and battery power. The same control can temporarily silence certain low-battery or end-of-life notifications, although batteries or the detector should always be replaced promptly when required.

The Gloria KO2D Carbon Monoxide Detector Manual highlights useful status messages on the display. "Lb" indicates low battery power, "Err" signals a fault, and "End" means the unit has reached the end of its service life. The detector is intended to be replaced ten years after installation, so recording the installation date is an important part of ongoing safety planning.

Placement matters

For effective protection, install a detector in rooms containing combustion appliances, while keeping it 1 to 3 meters away from the potential source. Additional alarms are recommended in sleeping areas and on every level of the home. Avoid humid bathrooms, garages, dusty locations, direct airflow, cooking appliances, and places where the unit may be blocked by furniture or curtains.

Important safety note

A CO alarm must never be ignored. If it sounds, move to fresh air, ventilate the area where safe to do so, and seek emergency assistance if symptoms or continued alarms occur. The KO2D detects carbon monoxide only. It does not replace smoke alarms, appliance servicing, adequate ventilation, or professional inspection of chimneys and fuel-burning equipment.

Note: Keep the detector clean using a soft cloth, vacuum, or dry compressed air. Do not use solvents, aerosols, paint, or cleaning chemicals near the sensor.

M: gpt-5.6-terra

© Copyright 2026 Manual.ly