Manual.ly Logo

General Electric GEP4-20kW Manual

0.0 · 0 Ratings

PDF manual · 55 Pages

English

M: OA-GPT-5-NAN
page

/ 55

Loading...
407763b73edca69b99a5e53904fa62b2a556 page 2b
38
08 System Commissioning
User Manual V1.1-2022-08-01
8�4 Monitoring via Power Sight
Power Sight is an monitoring platform used to manage organizations/users, add plants, and
monitor plant status.
For more details, refer to the Power Sight User Manual. Scan the QR code or visit https://www.
gesolarinverter.com/󽗉le/Power%20Sight%20User%20Manual-EN.pdf to get the user manual.
Power Sight
User Manual
Power Sight
8.3 Setting Inverter Parameters via WE Mate App
WE Mate app is a mobile application that communicates with the inverter via Bluetooth module, WIFi
module or GPRS module. Commonly used functions are as follows:
1. Check the operating data, software version, alarms, etc.
2. Set grid parameters, communication parameters, etc.
3. Equipment maintenance.
For more details, refer to the WE Mate APP User Manual. Scan the QR code or visit https://www.
gesolarinverter.com/images/FILES/DOWNLOADS/1-GLOBAL/4-USER-MANUALS/WeMate%20
APP%20User%20Manual-EN.pdf to get the user manual.
WE Mate App WE Mate App User Manual

Chat with your General Electric GEP4-20kW manual using AI

Get instant AI answers from your General Electric GEP4-20kW manual

Ask anything about the General Electric GEP4-20kW. Answers come from this manual, with the pages they are based on.

GEP4-20kW Maintenance Schedule

Remind me when maintenance is due
Every 6-12 months
Clean heat sink and vents

Check the heat sink, air intake, and air outlet for foreign matter or dust.

Show in the manual (page 43)
Every 6-12 months
Inspect electrical connections

Check that cables are securely connected and look for breaks or exposed copper cores.

Show in the manual (page 43)
Yearly
Check fan status

Verify the fan is working properly with low noise and has an intact appearance.

Show in the manual (page 43)
Yearly
Test DC switch operation

Turn the DC switch on and off ten consecutive times to ensure proper function.

Show in the manual (page 43)
Yearly
Verify terminal sealing

Ensure all terminals and ports are sealed; reseal cable holes if necessary.

Show in the manual (page 43)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend GEP4-20kW?

Yes No

Frequently Asked Questions

A

Dual MPPT (Maximum Power Point Tracking) means the inverter has two independent input trackers so each MPPT can optimize power from separate PV strings. This is useful when arrays face different orientations, slopes, or shading conditions, improving overall energy harvest.

Is this answer helpful?

A

GEP inverters support RS485, WiFi, LAN and optional 4G/Bluetooth modules. Local LCD and LEDs display status and errors. Mobile commissioning uses the WE Mate app; cloud monitoring and fleet management are available via the Power Sight platform for remote performance tracking and alerts.

Is this answer helpful?

A

The inverters include anti-islanding, residual current monitoring (RCMU), DC reverse polarity protection, AC overcurrent/short-circuit protection, surge arresters (DC type II, AC type III or optional type II), and optional arc-fault circuit interrupter (AFCI), rapid shutdown, and emergency power-off to meet grid and installer safety requirements.

Is this answer helpful?

A

Commissioning includes secure mounting and grounding, correct DC/AC wiring and sealing, setting grid parameters (voltage, frequency, grid type), configuring power limits and power factor, enabling LVRT/HVRT if required, and verifying communication via LCD or WE Mate app prior to powering on and grid connection.

Is this answer helpful?

A

Ensure PV string open-circuit voltage and short-circuit currents fall within each MPPT’s limits (max input voltage ~1100 V and MPPT current specs). Install dedicated AC circuit breakers sized per model (e.g., 16A–40A depending on inverter) and follow local regulations for RCD/RCMU and surge protection.

Is this answer helpful?

A

Routine checks every 6–12 months: clean heatsinks and ventilation, inspect fans and seals, verify cable terminations and DC switch operation annually. Address any faults promptly, validate firmware is up to date, and reseal any compromised ingress points to maintain IP65 protection.

Is this answer helpful?

A

Frequent issues include utility loss, voltage/frequency out-of-range, insulation/isolation failures, over-temperature or fan faults, and ARC alarms. Troubleshoot by checking grid supply, wiring/phase sequence, grounding, PV string insulation, ventilation and fan operation; collect serial, firmware and fault logs before contacting support.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High peak efficiency (≈98.3–98.4%) and strong European/CEC efficiencies for good energy yield.
  • Two independent MPPTs allow optimal performance with mixed-orientation or partially shaded arrays.
  • Comprehensive protections: anti-islanding, RCMU, surge arresters, DC reverse-polarity, optional AFCI and rapid shutdown.
  • Flexible communications: RS485, WiFi, LAN, 4G, Bluetooth plus app (WE Mate) and cloud monitoring (Power Sight).
  • IP65-rated, C4 corrosion class, and natural convection cooling allow indoor/outdoor installations with low noise.
VS

Disadvantages

  • Some advanced features (AFCI, rapid shutdown, emergency power-off) are optional and may add cost.
  • Large installations require separate AC breakers per inverter and careful sizing of upstream protection.
  • Commissioning and parameter tuning can be complex; trained technicians recommended.
  • Certain country-specific accessories or PV boxes are required (e.g., Australia) increasing logistics complexity.
  • High start-up and max input voltages demand careful string design to avoid over-voltage faults.
M: OA-GPT-5-NAN

Product Specification

Note

Prices partly include 0% VAT tax rates for AT and DE

Type

Solar inverter, transformerless, passive

MPP Voltage Range

140-950V Direct Current (DC)

Number of MPP Trackers

2

Output Phases

3-phase

Input

MC4

Output

Terminals

Interfaces

Wi-Fi (WLAN), LTE, RJ-45, RS-485, Modbus RTU

Noise Level

<25dB

IP Rating

IP65

Ambient Temperature

-22F to +140F

Dimensions

16.34x20.12x6.89in (WxHxD)

M: OA-GPT-54-NAN

Product Description

General Electric GEP 3-phase inverter / 2 MPPT Manual

The General Electric GEP three-phase inverter with dual MPPT is a robust grid-tied PV string inverter series designed for residential and commercial rooftop or small utility installations. Built to convert DC from photovoltaic arrays into stable three-phase AC for export to the grid, GEP models cover a wide power range (4 kW to 20 kW and up to 40 kW variants) while offering high efficiency, reliability, and flexible installation options.

Featuring two independent MPPT inputs, the GEP inverter maximizes energy harvest from arrays with differing orientations or partial shading. Start-up and operating voltages are wide-ranging (MPPT operating window typically 140–950 V) and the units support common grid voltages (220/380V, 230/400V, 240/415V). Peak conversion efficiencies exceed 98% and European/CEC efficiencies are competitive, making these inverters a strong choice where energy yield matters.

The GEP line emphasizes safety and protection: integrated DC reverse polarity protection, anti-islanding, residual current monitoring, surge arresters, and optional arc-fault interruption and rapid shutdown features meet modern grid and installer requirements. Built-in monitoring and communication options include RS485, WiFi, LAN and 4G modules, plus optional Bluetooth and app-based commissioning (WE Mate) and cloud monitoring (Power Sight). Local LCD and LED indicators provide real-time status, fault history, and parameter tuning.

Installation is straightforward with a reinforced mounting plate and IP65-rated enclosure for indoor or outdoor use. The manual details grounding, PE and AC wiring, recommended circuit breakers, AC and DC connector types (MC4/OT), ingress protection practices, and ventilation/clearance requirements. Commissioning workflows cover parameter setup through LCD or WE Mate app, power limiting (soft/hard limits), grid-type selection, power factor adjustment, and protections like LVRT/HVRT.

Maintenance guidance includes routine cleaning, fan and DC switch checks, electrical connection inspections, and sealing checks. Troubleshooting sections list common faults (grid loss, over/under voltage or frequency, insulation failures, fan faults, ARC warnings) with diagnostic steps and recommended actions. Technical specifications provide per-model input/output ratings, MPPT currents, efficiencies, thermal and environmental limits, dimensions, and accessory lists.

Overall, the General Electric GEP 3-phase inverter with 2 MPPTs offers a high-efficiency, feature-rich platform for three-phase PV installations that require flexible PV string configurations, robust safety/protection features, and modern monitoring and commissioning tools.

Notes

  • Dual MPPT supports arrays with differing orientations or shading.
  • Wide MPPT voltage range enables diverse string designs.
  • IP65 enclosure and C4 anti-corrosion rating suit outdoor use.
  • Multiple communications modules available for remote monitoring.
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly