GEP4-20kW Maintenance Schedule
Check the heat sink, air intake, and air outlet for foreign matter or dust.
Check that cables are securely connected and look for breaks or exposed copper cores.
Verify the fan is working properly with low noise and has an intact appearance.
Turn the DC switch on and off ten consecutive times to ensure proper function.
Ensure all terminals and ports are sealed; reseal cable holes if necessary.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend GEP4-20kW?
Yes NoFrequently Asked Questions
Dual MPPT (Maximum Power Point Tracking) means the inverter has two independent input trackers so each MPPT can optimize power from separate PV strings. This is useful when arrays face different orientations, slopes, or shading conditions, improving overall energy harvest.
Is this answer helpful?
GEP inverters support RS485, WiFi, LAN and optional 4G/Bluetooth modules. Local LCD and LEDs display status and errors. Mobile commissioning uses the WE Mate app; cloud monitoring and fleet management are available via the Power Sight platform for remote performance tracking and alerts.
Is this answer helpful?
The inverters include anti-islanding, residual current monitoring (RCMU), DC reverse polarity protection, AC overcurrent/short-circuit protection, surge arresters (DC type II, AC type III or optional type II), and optional arc-fault circuit interrupter (AFCI), rapid shutdown, and emergency power-off to meet grid and installer safety requirements.
Is this answer helpful?
Commissioning includes secure mounting and grounding, correct DC/AC wiring and sealing, setting grid parameters (voltage, frequency, grid type), configuring power limits and power factor, enabling LVRT/HVRT if required, and verifying communication via LCD or WE Mate app prior to powering on and grid connection.
Is this answer helpful?
Ensure PV string open-circuit voltage and short-circuit currents fall within each MPPT’s limits (max input voltage ~1100 V and MPPT current specs). Install dedicated AC circuit breakers sized per model (e.g., 16A–40A depending on inverter) and follow local regulations for RCD/RCMU and surge protection.
Is this answer helpful?
Routine checks every 6–12 months: clean heatsinks and ventilation, inspect fans and seals, verify cable terminations and DC switch operation annually. Address any faults promptly, validate firmware is up to date, and reseal any compromised ingress points to maintain IP65 protection.
Is this answer helpful?
Frequent issues include utility loss, voltage/frequency out-of-range, insulation/isolation failures, over-temperature or fan faults, and ARC alarms. Troubleshoot by checking grid supply, wiring/phase sequence, grounding, PV string insulation, ventilation and fan operation; collect serial, firmware and fault logs before contacting support.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- High peak efficiency (≈98.3–98.4%) and strong European/CEC efficiencies for good energy yield.
- Two independent MPPTs allow optimal performance with mixed-orientation or partially shaded arrays.
- Comprehensive protections: anti-islanding, RCMU, surge arresters, DC reverse-polarity, optional AFCI and rapid shutdown.
- Flexible communications: RS485, WiFi, LAN, 4G, Bluetooth plus app (WE Mate) and cloud monitoring (Power Sight).
- IP65-rated, C4 corrosion class, and natural convection cooling allow indoor/outdoor installations with low noise.
Disadvantages
- Some advanced features (AFCI, rapid shutdown, emergency power-off) are optional and may add cost.
- Large installations require separate AC breakers per inverter and careful sizing of upstream protection.
- Commissioning and parameter tuning can be complex; trained technicians recommended.
- Certain country-specific accessories or PV boxes are required (e.g., Australia) increasing logistics complexity.
- High start-up and max input voltages demand careful string design to avoid over-voltage faults.
Product Specification
Note
Prices partly include 0% VAT tax rates for AT and DE
Type
Solar inverter, transformerless, passive
MPP Voltage Range
140-950V Direct Current (DC)
Number of MPP Trackers
2
Output Phases
3-phase
Input
MC4
Output
Terminals
Interfaces
Wi-Fi (WLAN), LTE, RJ-45, RS-485, Modbus RTU
Noise Level
<25dB
IP Rating
IP65
Ambient Temperature
-22F to +140F
Dimensions
16.34x20.12x6.89in (WxHxD)
Product Description
General Electric GEP 3-phase inverter / 2 MPPT Manual
The General Electric GEP three-phase inverter with dual MPPT is a robust grid-tied PV string inverter series designed for residential and commercial rooftop or small utility installations. Built to convert DC from photovoltaic arrays into stable three-phase AC for export to the grid, GEP models cover a wide power range (4 kW to 20 kW and up to 40 kW variants) while offering high efficiency, reliability, and flexible installation options.
Featuring two independent MPPT inputs, the GEP inverter maximizes energy harvest from arrays with differing orientations or partial shading. Start-up and operating voltages are wide-ranging (MPPT operating window typically 140–950 V) and the units support common grid voltages (220/380V, 230/400V, 240/415V). Peak conversion efficiencies exceed 98% and European/CEC efficiencies are competitive, making these inverters a strong choice where energy yield matters.
The GEP line emphasizes safety and protection: integrated DC reverse polarity protection, anti-islanding, residual current monitoring, surge arresters, and optional arc-fault interruption and rapid shutdown features meet modern grid and installer requirements. Built-in monitoring and communication options include RS485, WiFi, LAN and 4G modules, plus optional Bluetooth and app-based commissioning (WE Mate) and cloud monitoring (Power Sight). Local LCD and LED indicators provide real-time status, fault history, and parameter tuning.
Installation is straightforward with a reinforced mounting plate and IP65-rated enclosure for indoor or outdoor use. The manual details grounding, PE and AC wiring, recommended circuit breakers, AC and DC connector types (MC4/OT), ingress protection practices, and ventilation/clearance requirements. Commissioning workflows cover parameter setup through LCD or WE Mate app, power limiting (soft/hard limits), grid-type selection, power factor adjustment, and protections like LVRT/HVRT.
Maintenance guidance includes routine cleaning, fan and DC switch checks, electrical connection inspections, and sealing checks. Troubleshooting sections list common faults (grid loss, over/under voltage or frequency, insulation failures, fan faults, ARC warnings) with diagnostic steps and recommended actions. Technical specifications provide per-model input/output ratings, MPPT currents, efficiencies, thermal and environmental limits, dimensions, and accessory lists.
Overall, the General Electric GEP 3-phase inverter with 2 MPPTs offers a high-efficiency, feature-rich platform for three-phase PV installations that require flexible PV string configurations, robust safety/protection features, and modern monitoring and commissioning tools.
Notes
- Dual MPPT supports arrays with differing orientations or shading.
- Wide MPPT voltage range enables diverse string designs.
- IP65 enclosure and C4 anti-corrosion rating suit outdoor use.
- Multiple communications modules available for remote monitoring.