Fluke 1587 FC Manual
PDF manual · 48 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your Fluke 1587 FC manual using AI
Get instant AI answers from your Fluke 1587 FC manual
Ask anything about the Fluke 1587 FC. Answers come from this manual, with the pages they are based on.
1587 FC Maintenance Schedule
Wipe the case occasionally with a damp cloth and mild detergent. Do not use abrasive or solvent cleaners.
Replace the batteries as soon as the weak battery symbol (b) or batt message appears on the display to prevent incorrect readings.
Check continuity of test leads before use; do not use if readings are high or erratic.
Check the fuse before making current measurements to ensure safety and accurate operation.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend 1587 FC?
Yes NoFrequently Asked Questions
It supports CAT III 1000 V and CAT IV 600 V standards. This ensures protection against dangerous transients in primary distribution levels. Users must follow safety guidelines to maintain these ratings during operation.
Is this answer helpful?
Yes, models 1587 and 1587T support capacitance and temperature measurements. The base 1577 model does not include these specific functions. Check the specific model number before purchasing for these features.
Is this answer helpful?
Battery life is approximately 1000 hours during normal measurement usage. Insulation testing consumes more power but supports around 1000 tests per charge. Replace batteries when the weak icon appears for accurate results.
Is this answer helpful?
The minimum insulation test voltage is 50 volts on specific models like 1587T. Standard models like 1587 start at 100 volts or higher depending on configuration. Select the correct voltage setting by referring to operational instructions.
Is this answer helpful?
Press and hold the blue button during startup to disable the power saving mode. You can also keep measuring to prevent automatic shut off in some modes. This ensures continuous operation without interruption for long tests.
Is this answer helpful?
Users can operate this device in non-hazardous locations safely. Explosion-proof environments require specific approvals not standard on this unit. Verify local regulations before using it in hazardous atmospheric conditions.
Is this answer helpful?
A weak battery symbol appears and the backlight turns off automatically. Measurements may become inaccurate so replace batteries immediately. Do not rely on readings if the warning symbol is visible on the screen.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- High safety CAT III and CAT IV ratings protect against dangerous voltages.
- True RMS measurement ensures accuracy for non-sinusoidal waveforms accurately.
- Insulation testing up to 1000V supports deep system diagnostics efficiently.
- Durable construction withstands falls on concrete floors without failure.
- Long battery life supports extended use during critical work shifts daily.
Disadvantages
- Battery replacement required frequently if used for high voltage insulation testing often.
- Limited capacitance and temperature features on the 1577 compared to other variants.
- Manual range override deactivates auto range which limits ease of use initially.
- Replacement parts can be costly if accidental damage occurs during heavy use.
- Heavy weight might cause hand fatigue during prolonged overhead testing sessions.
Product Specification
Includes
Insulation Tester 1587FC, Current Clamp i400, Phase Sequence Indicator 9040
Package Contents
Bag, Test Leads
Product Description
Fluke 1587/MDT FC Measuring Set Overview
The electrical industry requires tools that balance high performance with exceptional safety ratings for technicians working on complex distribution systems where reliability is non-negotiable. Understanding the full scope of your equipment is vital for successful diagnostics when consulting the Fluke 1587/MDT FC Measuring Set Manual provides essential insights into proper operation and maintenance strategies for every user. This comprehensive instrument series offers versatile testing capabilities for various environments and it supports true rms measurements ensuring accuracy across different waveforms while the device is designed to withstand harsh conditions found in professional settings reliably.
Advanced measurement capabilities handle a wide array of electrical parameters efficiently allowing users to measure alternating and direct voltage up to 1000 volts with high precision current measurement capabilities extend to significant amperage levels for power systems. The isolation resistance function allows deep testing at high voltages up to 1000 volts on premium models while specific models support additional functions like temperature and capacitance checks using thermocouples or frequency analysis assists in identifying signal issues within electrical circuits. The large LCD display provides clear readings including range and unit information and users find the layout intuitive with clearly labeled buttons and switches making operation simple for anyone.
Electricians prioritize safety above all else when connecting equipment to ensure they adhere to strict CAT III 1000V and CAT IV 600V standards for primary protection against voltage transients found in industrial settings. Internal circuits feature automatic overload protection to prevent damage from high currents and low battery warnings ensure measurements remain accurate during operation before failure occurs preventing accidents. Battery life remains strong using standard alkaline power sources available locally and the device includes a power saving mode to conserve energy during inactive periods automatically without needing manual input.
Min-max recording tracks fluctuating signals over extended durations without manual intervention required and the rugged case design survives falls on hard concrete floors easily during transport for long term use. Many features align with international industry safety protocols and regulations allowing users to appreciate the long warranty period offered by the manufacturer for peace of mind throughout the operational life. Each unit undergoes rigorous testing before reaching customers to ensure quality standards are met consistently across all batches sold globally.
The 1587 model includes capacitance and temperature measurement which the 1577 lacks while the 1587T version features a compact design making it suitable for specific tasks where space is limited. Product integrity is backed by a multi-year manufacturer guarantee starting at shipment and authorized service centers handle repairs and replacements to maintain quality standards globally for customers. Choosing the right meter impacts job efficiency and safety outcomes significantly and proper usage guidelines ensure longevity and reliability for all operators over time for sustained performance.
Regular maintenance keeps performance optimal for years of heavy use in demanding sectors requiring top tier durability. The rotary switch allows quick access to different measurement modes easily without navigating complex menus that slow down workflow in the field. Safety notes: Always verify voltage before measuring and disconnect power for resistance checks to avoid injury or device damage during use.