a480050fcee42d8e1381da121bc30d873685 page 1
1507/1503
Insulation Testers
Bedienungshandbuch
June 2005 Rev. 1, 2/19 (German)
2005-2019 Fluke Corporation. All rights reserved.
All product names are trademarks of their respective companies.

Chat with your Fluke 1507 manual using AI

Get instant AI answers from your Fluke 1507 manual

Ask anything about the Fluke 1507. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend 1507?

Yes No
0
User Pic

Winona Wisoky

6 months ago

Does this insulation tester replace a regular multimeter, and how accurate is it?

0
User Pic

Manual.ly

6 months ago

The device is designed primarily for insulation resistance testing and performs this core function accurately across common voltage ranges. Its additional multimeter functions are basic, with coarser resolution and higher tolerances than a dedicated quality multimeter. It is best used as a supplementary instrument rather than a replacement for a full-featured multimeter.

M: gpt-5.6-terra
M: gpt-5.6-terra

Frequently Asked Questions

A

The Fluke 1507 measures insulation resistance, AC/DC voltage, and resistance to earth potential. It is intended for electrical installation, maintenance, and troubleshooting work.

Is this answer helpful?

A

The Fluke 1507 offers 50 V, 100 V, 250 V, 500 V, and 1000 V DC insulation test voltages. This helps users select a suitable level for the equipment being evaluated.

Is this answer helpful?

A

The Fluke 1507 measures insulation resistance from 0.01 Mohm up to 10 Gohm. Range and resolution depend on the selected test voltage.

Is this answer helpful?

A

Yes. The tester detects potentially hazardous voltage and blocks insulation testing when more than 30 V is present at the input. It also displays a hazardous-voltage warning symbol.

Is this answer helpful?

A

Polarization Index and Dielectric Absorption Ratio tests compare insulation resistance readings over timed intervals. They can provide additional insight into insulation condition beyond a single resistance measurement.

Is this answer helpful?

A

Yes. When the test button is released or a timed test finishes, the Fluke 1507 automatically discharges the tested circuit through the instrument.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Measures insulation resistance from 0.01 Mohm to 10 Gohm with five selectable test voltages from 50 V to 1000 V DC.
  • Includes PI and DAR timed insulation tests for more detailed condition assessment.
  • Compare function provides adjustable pass/fail limits and a visible green pass indicator.
  • Measures AC/DC voltage to 600 V and resistance to 20 kohm in one compact instrument.
  • Live-circuit detection, automatic discharge, CAT IV 600 V rating, and lock function support safer workflows.
VS

Disadvantages

  • PI, DAR, and Compare functions are specific to the Fluke 1507 and are not available on the 1503 model.
  • Insulation and resistance tests require circuits to be de-energized before testing.
  • The IP40 environmental rating provides limited protection against dust and no water protection.
  • Backlight shuts off after two minutes, which may be inconvenient during long inspections.
  • Uses replaceable AA alkaline batteries rather than a rechargeable battery pack.
M: gpt-5.6-terra

Product Specification

Measurement range

0.01 Mohm-10 Gohm

Accuracy

+/-0.01 kohm

M: gpt-5.6-terra

Product Description

Fluke 1507 Insulation Tester - Read, Download & Print Free

The Fluke 1507 Insulation Tester is a professional handheld instrument designed for electrical maintenance, installation checks, and troubleshooting. It combines insulation resistance testing with AC/DC voltage measurement and earth-bond resistance measurement, helping technicians assess wiring, motors, control panels, and other electrical equipment with confidence.

Flexible insulation testing for demanding work

The Fluke 1507 provides selectable DC test voltages of 50 V, 100 V, 250 V, 500 V, and 1000 V. Its insulation measurement range extends from 0.01 Mohm to 10 Gohm, offering the flexibility needed for a broad variety of low- and medium-voltage applications. A clear digital display presents primary readings, applied test voltage, warning indicators, and measurement units for straightforward interpretation in the field.

For advanced insulation assessment, the 1507 includes Polarization Index (PI) and Dielectric Absorption Ratio (DAR) tests. These timed functions help identify insulation condition trends beyond a single resistance result. The built-in Compare feature also supports faster decisions by allowing users to set a pass/fail threshold from 100 kohm to 500 Mohm. A green pass indicator appears when the measured insulation resistance exceeds the selected limit.

Built with practical safety features

Safety is central to the Fluke 1507 Insulation Tester. It detects live circuits and prevents insulation tests when input voltage exceeds 30 V. After an insulation test, the instrument automatically discharges the circuit to reduce residual-voltage risk. It is rated CAT IV 600 V and meets key IEC safety and insulation-testing standards, making it suitable for professional electrical environments when used with approved accessories and proper procedures.

The tester also includes a lock function for extended tests, a backlit display for dim work areas, low-battery indication, and an automatic sleep mode that helps preserve battery life. Four AA alkaline batteries support up to 1,000 standard insulation tests or 2,500 standard resistance tests under specified conditions.

Everyday measurement capability

Beyond insulation testing, the Fluke 1507 measures AC or DC voltage up to 600 V and resistance from 0.01 ohm to 20 kohm. Lead compensation can reduce the effect of test-lead resistance during low-resistance checks. Its compact body measures approximately 20.3 cm long and weighs about 550 g, supporting convenient transport between job sites.

Notes

  • Perform insulation and resistance tests only on de-energized circuits.
  • Inspect leads, housing, batteries, and fuse before use.
  • Use properly rated personal protective equipment and accessories for the measurement category.