88fcde1525ce955e545ff44928a15531b7a0 page 9
CA 10.8
9
Displays of LED
Charging process
CAUTION!
Use only original batteries in the supplied
battery charger.
NOTE
Battery and charger heat up during the
charging process. This is perfectly normal!
Insert the charger mains plug.
The LED fault message and the LED
charge status light up for a short time.
Insert battery into the charger as far as
stop.
The LED charge status flashes and the
battery is charged.
When the battery is fully charged, the
LED charge status is lit continuously.
Remove the battery from the charger.
Pull out the mains plug.
Fault messages
If the LED fault message lights up after the
battery is inserted into the charger, there is
an fault with the battery or charger.
The LED warning message is lit up
continuously:
– The battery is too hot or too cold.
The charging process starts when the
battery reaches the charging tempera-
ture (0°C...40°C).
The LED fault message flashes or none
of the two LEDs lights up:
– Remove battery from the charger.
Check contacts at charger and battery
for contamination and clean if necessary.
Reinsert battery. The battery is faulty
if the same display appears again.
Replace battery or have it checked in
a professional workshop.
– If this fault message is also displayed
with a different battery, then there is
a fault with the charger. Have the charger
checked by a professional workshop.
Maintenance and care
WARNING!
Before performing any work, pull out the
mains plug. Do not use water or liquid
detergents.
Remove dirt and dust from the housing
with a paint brush or dry cloth.
red green
off flashes Battery is charging.
off on
Charging process finished.
Maintenance charging.
See “Charging process”.
flashes off
Battery is too hot or too
cold.
on off Battery or charger is faulty.
See “Fault messages”.

Chat with your Flex CA 10.8 manual using AI

Get instant AI answers from your Flex CA 10.8 manual

Ask anything about the Flex CA 10.8. Answers come from this manual, with the pages they are based on.

CA 10.8 Maintenance Schedule

Before each use
Inspect charger, cable, and plug for damage

Check the battery charger, cable, and plug before every use. Do not use if any damage is detected to avoid electric shock.

As needed
Clean housing with dry brush or cloth

Remove dirt and dust from the housing using a paint brush or dry cloth. Never use water or liquid detergents.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend CA 10.8?

Yes No

Frequently Asked Questions

A

The charger is designed for original FLEX AP 10.8/2.5, AP 10.8/4.0, and AP 10.8/6.0 battery packs. Use only compatible original batteries with the correct voltage.

Is this answer helpful?

A

Approximate charging times are 40 minutes for a 2.5 Ah battery, 55 minutes for a 4.0 Ah battery, and 85 minutes for a 6.0 Ah battery. Actual time depends on the battery's remaining charge.

Is this answer helpful?

A

A flashing green LED means the battery is currently charging. When the green LED remains steadily lit, charging is complete and the charger is maintaining the battery charge.

Is this answer helpful?

A

A steady red LED usually means the battery is too hot or too cold. Charging starts automatically when the battery temperature returns to the permitted 0 C to 40 C range.

Is this answer helpful?

A

No. The Flex CA 10.8 Charger is intended for indoor use only. Keep it away from rain, moisture, and damp locations to reduce the risk of electric shock.

Is this answer helpful?

A

Disconnect the charger from the mains first. Remove dust and dirt from the housing with a dry cloth or soft brush. Do not use water or liquid cleaning products.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Supports FLEX AP 10.8/2.5, AP 10.8/4.0, and AP 10.8/6.0 batteries.
  • Provides clear green charge-status and red fault-status LED indicators.
  • Charges 2.5 Ah, 4.0 Ah, and 6.0 Ah batteries in about 40, 55, and 85 minutes.
  • Compact 0.52 kg design with ventilation slots and a dedicated battery bay.
  • Includes maintenance charging after a battery reaches full charge.
VS

Disadvantages

  • Compatible only with specified FLEX 10.8 V AP battery types.
  • Designed for indoor use and must be protected from rain and moisture.
  • Requires a 220-240 V mains supply, which may limit use in other regions.
  • Charging is restricted to battery temperatures between 0 C and 40 C.
  • Faulty batteries or chargers require inspection by an authorized service center.
M: gpt-5.6-terra

Product Specification

Type

Charger

Suitable for

Flex

Battery voltage

10.8 V

Battery type

Lithium-ion

Weight

1.15 lb

M: gpt-5.6-terra

Product Description

Flex CA 10.8 Charger - Read, Download & Print Free

The Flex CA 10.8 Charger is a compact charging solution designed for compatible FLEX 10.8 V battery packs. Flex CA 10.8 Charger - Read, Download & Print Free highlights the essential product information for users who need dependable charging support for their cordless tool system. It is intended for FLEX AP 10.8/2.5, AP 10.8/4.0, and AP 10.8/6.0 batteries, helping professionals and home users keep compatible equipment ready for work.

Designed for the FLEX 10.8 V Battery Range

This charger operates from a 220-240 V, 50-60 Hz mains supply and delivers a 12.6 V charging voltage. Its dedicated battery slot, integrated contacts, ventilation openings, and attached power cord create a straightforward setup. Insert a compatible original battery fully into the charging bay, monitor the indicator lights, and remove the battery when charging is complete.

Charging times vary by battery capacity and its remaining charge. A 2.5 Ah battery takes approximately 40 minutes, a 4.0 Ah battery takes around 55 minutes, and a 6.0 Ah battery takes about 85 minutes. These timings make the CA 10.8 a practical choice for managing battery rotation during workshop, installation, repair, and maintenance tasks.

Clear LED Charging Information

The CA 10.8 uses a green LED for charge status and a red LED for fault messages. A flashing green light indicates active charging, while a steady green light confirms the battery is fully charged and maintenance charging is active. This simple visual feedback lets users check battery status at a glance.

The red fault LED also supports safer operation. A steady red light can mean the battery is outside the permitted charging temperature range. Charging begins automatically once the battery reaches a temperature between 0 C and 40 C. A flashing red light, or no LED display, may indicate dirty contacts, a faulty battery, or a charger fault that should be inspected by an authorized service center.

Safe Everyday Charging

The charger is rated for indoor use and should be kept dry, clean, and uncovered while operating. Do not charge batteries below 0 C or above 40 C, and avoid humid or excessively hot surroundings. Before use, inspect the charger, cable, and plug for damage. Cleaning should be done only after unplugging the unit, using a dry cloth or brush rather than water or liquid cleaners.

Notes

  • Use original compatible FLEX batteries only.
  • Battery and charger warmth during charging is normal.
  • Do not place objects on the charger or use it on soft surfaces.
  • Recycle used chargers and batteries through appropriate collection systems.
M: gpt-5.6-terra

© Copyright 2026 Manual.ly