Important
information
Please read this manual before attempting to
install or commission the charger.
Safety instructions for installation
• Do not carry out outdoor installation during
precipitation or strong winds if there is a risk
that water or debris may enter the device.
• Carry out all operations described in this
manual after ensuring that there is no voltage
in the power cord.
• This product may only be installed, repaired or
serviced by an authorised electrician.
• All local, regional and national electrical
installation regulations must be observed.
• Installation must not be carried out near
explosive atmospheres or in areas where there
is a risk of running water.
• Risk to life from high electrical voltages.
• The product must be permanently installed in
its nal location.
• The product must be installed on a wall or
structure with sufcient load bearing capacity.
• The clamps on the rear panel are live when the
power circuit is closed and must never come
into direct contact with anything other than the
Lumina plug-in electronics.
• Lumina’s network SSID and password are
required for installation and conguration;
they can be found on the back of the charging
head.
Safety instructions for use
• Never use or touch the device if it is damaged
or not functioning properly.
• Always perform the recommended
maintenance, installation and any repair
work by an authorised service centre and in
accordance with local requirements.
• Do not use water to extinguish a re.
• Never clean the station with high pressure or
running water.
• Do not immerse the station in water or other
liquids.
• If the light bar on the device lights up red, there
is an error.
• Never touch the contacts of the type 2 socket/
plug and never insert foreign objects into it.
• Never use the charging cable if it is damaged
or if the connector is wet or dirty.
• Do not use extension cables or adapters in
connection with the station.
• The charging cable can only be disconnected
from the station by pulling on the plug handle,
not on the cable.
• Make sure that the charging cable does not
cause a tripping or running over hazard.
• Even though the station is designed to
withstand normal weather conditions, it
is recommended to protect it from direct
sunlight or exposure to extreme weather
conditions.
• Do not use the station near strong
electromagnetic elds or in the immediate
vicinity of radio transmitters.
6

Chat with your Enelion Lumina manual using AI

Get instant AI answers from your Enelion Lumina manual

Ask anything about the Enelion Lumina. Answers come from this manual, with the pages they are based on.

Lumina Maintenance Schedule

Periodically
Clean the charging station

Never clean with high pressure or running water. Do not immerse in liquids. Use a damp cloth if needed.

Before each use
Inspect cable and connectors

Do not use if damaged, wet, or dirty. Check for tripping hazards. Ensure plug is pulled by handle, not cable.

As recommended
Perform technical tests

Measure continuity of protective conductors and effectiveness of electric shock protection as per manual.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Lumina?

Yes No

Frequently Asked Questions

A

The installation process is designed for speed and can be completed in no more than fifteen minutes of the installation process.

Is this answer helpful?

A

A flashing or steady red light indicates an error or fatal error respectively. You should stop using the station and report the situation immediately.

Is this answer helpful?

A

No. Due to the IP 54 class, it is forbidden to wash the charger with pressure washers or any other stream of water.

Is this answer helpful?

A

Connect the cable to the charger and then to the car. For Freecharge, it starts automatically. For RFID, place the tag on the reader first.

Is this answer helpful?

A

One-phase systems support 1.4 to 7.4 kW. Three-phase systems support power capacity up to 22 kW for faster delivery.

Is this answer helpful?

A

You can update the software using the Update section in the configuration panel via a web browser connected to the device.

Is this answer helpful?

A

This product may only be installed, repaired or serviced by an authorized electrician or authorized service centre.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Quick installation completes in fifteen minutes or less for most scenarios
  • Modular structure allows easy upgrades and changes to the base module
  • Supports multiple connectivity options including WiFi and GSM LTE networks
  • LED bar provides clear visual status indicators for operation and errors
  • Remote software updates and diagnostics support long-term reliability
VS

Disadvantages

  • Installation requires a certified electrician following local safety regulations
  • Device cannot be cleaned with high pressure water due to IP 54 rating
  • Freecharge mode limits advanced billing features without system integration
  • Network configuration requires specific access to the configuration panel
  • Locking mechanisms may need specific configuration to match station setup
M: QW-35-FL

Product Specification

Number of charge points

1

Maximum charging power

22kW 3-phase

Charging mode

IEC 61851-1 (Mode 3)

Number of phases

3-phase

Voltage

400V (AC)

Max current per phase

32A

Plug type

Type 2

Connector type

Socket

Mounting

Wall mounted

Authentication

RFID

Interfaces

LTE, OCPP, Wi-Fi

Features

Shutter

IP Rating

IP54

Dimensions

6.10x15.35x5.24in (WxHxD)

Weight

9.26lbs

M: QW-35-FL

Product Description

Discover Electric Charging Excellence

The Enelion Lumina Charging Socket Manual provides essential insights for modern electric vehicle owners who want reliable and fast power delivery. This device transforms how we approach power distribution at home or commercial locations. With a modular structure, users can build and upgrade their solution using the same base module without disruption or significant downtime. Installation is designed for speed, allowing the unit to become online in just under fifteen minutes. This efficiency saves time for both professional installers and business owners managing electric fleets.

Safety and Operation

Proper operation ensures longevity and security for the entire electrical system. The unit meets high standards for protection against water and dust, classified as IP 54. This means it withstands normal weather conditions but requires careful placement away from direct water streams or intense sunlight. Safety instructions emphasize that only authorized electricians should handle installation or repairs to prevent accidents. High voltage risks are real, so strict adherence to local electrical codes is mandatory during setup. The device features an LED bar that communicates status clearly through colors for the user. Green indicates availability while red signals fatal errors requiring immediate attention.

Configuration and Connectivity

Connectivity options define the future of charging infrastructure for smart buildings. The system supports WiFi and GSM LTE communication for seamless internet access in various locations. Advanced management systems compliant with OCPP 1.6 allow remote diagnostics and software updates over the air. Users can configure the station as Freecharge where connection triggers charging automatically, or use RFID authorization for added control and security. Power limits range from 1.4 kW to 22 kW depending on the phase system available. One-phase setups suit 1.4 to 7.4 kW while three-phase options handle up to 22 kW.

Monitoring and Maintenance

The configuration panel offers deep insights into network topology and connection status. Administrators can view active alerts, signal strength, and firmware versions easily. Scheduling features allow users to program charging times to off-peak hours for cost savings. Physical security is also enhanced by locking mechanisms that prevent unauthorized cable removal. Emergency protocols cover fire situations where disconnecting power is the first step before calling services. Regular maintenance keeps the station reliable over many years. Cleaning should never involve high pressure water. By following the guidelines, users ensure consistent performance. Refer to the Enelion Lumina Charging Socket Manual for specific setup steps.