Manual.ly Logo

Endress Diesel Generator Manual

0.0 · 0 Ratings

PDF manual · 58 Pages

English

M: QW-35-FL
page

/ 58

Loading...
ec798440c7e48cc7263b59d4c6de2ea87aa6 page 11
STOPPING THE GENERATOR (8.1):
Switch off or disconnect all the accessories powered by the generator: then stop the engine after letting it idle for 2-3 minutes to cool
down; to stop the generator turn off the switch.
With electrically started generators, turn the key to the “OFF” position.
ATTENTION: the engine will remain hot even after being switched off: make sure the generator is well ventilated even after engine shut
down.
MAINTENANCE (9.1):
As regards this important paragraph please carefully consult the use and maintenance manual published by the makers of the
engine: if you spend some time now you will save money later!
ATTENTION: WHEN REQUESTING SPARE PARTS CHECK YOUR REQUIREMENTS AGAINST THE SCHEDULE IN THIS MA-
NUAL.
• Normal battery, alternator and frame maintenance operations are reduced to a minimum: keep the battery terminals well greased and
top up with distilled water when the plates are uncovered.
• No special maintenance operations are required for the commutator system – brush holder – brushes – as they are designed to gua-
rantee reliable and prolonged service.
• When requesting spare parts, as shown in the attached current Manual, it is essential that they are quoted in sequential order, supplying
the code number of the piece required, the registered number of the generator, its commercial name and the date of construction (see
Appendix of the list of spare parts attached to the current Manual).
NOTE: In order to observe the Directive 2000/14/CE, it is recommended that periodical checks ( at least every 6 months ) be carried out
on the components that may be subject to wear and tear during normal running conditions, and that may as a consequence cause an
increase in machine noise. The following is a list of components that should be checked:
Exhaust pipe
If a problem arises in one or more of these components, the nearest authorized service centre should be contacted.
Silent-Blocks
Air fi lter
Mounting of mechanical parts
Engine and alternator fans
Good working order of the machine
Sound absorbing and sound insulating materials ( where present )
NOTE: When disposing of used oil or residual fuel, respect the environment. We suggest collecting waste product in drums for delivery
at a later date to a nearby Service Station. Do not deposit oil and residual fuel into the earth or into unsuitable receptacles.
NOTE: Bad operation of the generator due to faults in the engine (oscillation, low number of revs, etc.) is of exclusive competence of the
departments of the engine makers’ customer service, both during and after the warranty period. Tampering or intervention carried out
by personnel unauthorized by the makers will invalidate the conditions of guarantee.
Malfunction of the generator due to faults in the electrical circuits and in the frame is of exclusive competence of the makers’ customer
service department. Repairs carried out by unauthorized personnel, substitution of components with unoriginal spare parts and tampering
with the generator will invalidate the conditions of warranty.
The makers do not accept any liability arising out of faults or accidents due to neglect, incapacity or installation by not qualifi ed tech-
nicians.
CLEANING (10.1):
Turn off the machine and wait until the hot parts have cooled down before proceeding.
It is recommended that the machine not be cleaned with jets of water or infl ammable products. Use special products or a damp cloth if
necessary; in the latter case pay attention to the electrical components.
Before turning the machine back on make sure that it is completely dry.
TRANSPORTATION (11.1):
• It is a good rule during transportation to fi rmly fi x the generator so that it cannot turn over; remove all fuel and make that acid or fumes
do not leak from the battery (if present).
Check the overall weight of the machine to be transported by road.
Under no circumstances should the generator be started while inside a truck.
STORAGE (12.1):
If you do not intend to use the generator for more than thirty days, it is advisable to completely drain the fuel tank.
For petrol engines it is important to drain also the carburetor fl oat chamber: petrol left in contact with components for a long period will
cause them to deteriorate due to the rubbery deposits typical to this fuel.
ATTENTION: Petrol is extremely infl ammable and explosive under certain conditions. Avoid smoking and sparks in the vicini-
ty.
• Substitute the engine with oil if it is fi nished: when the engine is not in use, it could damage the thermal group and the connecting
rods.
• Clean the generator accurately, disconnect the battery cables (if present) and cover well to protect from dust and damp.
11

Chat with your Endress Diesel Generator manual using AI

Get instant AI answers from your Endress Diesel Generator manual

Ask anything about the Endress Diesel Generator. Answers come from this manual, with the pages they are based on.

Diesel Generator Maintenance Schedule

Remind me when maintenance is due
Every 6 months
Inspect noise-reducing components

Check exhaust pipe, silent-blocks, air filter, mechanical tightening, fans, and sound insulation for wear to ensure compliance with noise directives.

Show in the manual (page 17)
When plates are uncovered
Top up battery with distilled water

Keep battery terminals well greased and top up elements with distilled water when the plates become uncovered.

Show in the manual (page 17)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Diesel Generator?

Yes No

Frequently Asked Questions

A

No, do not run in closed areas. Engines produce carbon monoxide. Ensure proper ventilation to avoid poisoning risks.

Is this answer helpful?

A

Use only unleaded petrol for gasoline models or diesel fuel as specified. Other fuels cause irreversible damage to the engine.

Is this answer helpful?

A

Check on a horizontal surface. Fill to ideal level shown in manual to prevent severe internal engine damage.

Is this answer helpful?

A

Warranty depends on authorized service. Tampering by unauthorized personnel voids conditions immediately.

Is this answer helpful?

A

Disconnect loads then idle for two to three minutes to cool down before switching off the engine.

Is this answer helpful?

A

Check protection switches and fuses. Verify connections and condensers are in good condition before restarting.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Robust design supports dual voltage and varied electrical configurations for different load needs.
  • Comprehensive safety protocols protect users from electrocution and exhaust fume risks significantly.
  • Accessible maintenance points streamline routine checks like oil and filter inspections easily.
VS

Disadvantages

  • Requires strict ventilation to prevent carbon monoxide poisoning in enclosed areas effectively.
  • Initial fueling and oil checks must be performed carefully before first startup sequence.
  • Electrical connections often require qualified technicians to ensure safe wiring installation properly.
  • High temperatures remain after shutdown posing burn risks near exhaust components immediately.
M: QW-35-FL

Product Specification

Type

Diesel Generator

Engine Power

5.7kW (7.64HP), 26.55in3, 3000RPM, 4-stroke, Yanmar L100

Rated Power

3kW (230V), 4.5kW (400V)

Fuel Tank Capacity

6.34gal

Display

No

Protection Class

IP23

Noise Level

105dB(A)

Weight

273.37lb

M: QW-35-FL

Product Description

Discovering Reliability with Endress Power Solutions

When you need dependable energy during sudden outages or remote work, finding the right equipment is crucial for success. The Endress Diesel-Generator stands out as a robust choice for applications requiring consistent power output regardless of environmental conditions. Whether for residential backup protection or industrial operations demanding continuous flow, this machine delivers performance where it counts most. Understanding how to operate such machinery safely and efficiently is vital for safety and equipment longevity. Proper guidance ensures users avoid common pitfalls during installation and daily use.

Key Features and Versatility

These units are designed with versatility in mind for diverse user groups. Many models allow dual voltage configurations providing greater flexibility for different electrical setups. You might find options for single phase or three phase outputs depending on specific load requirements. This adaptability makes them suitable for sites ranging from small workshops to larger construction projects. Maintenance is streamlined through accessible components like filter systems and battery chargers which simplify routine checks. Ensuring stability on horizontal surfaces guarantees optimal oil and fuel flow to the engine. If vertical operation is impossible, anchoring and leveling methods are necessary. Shelter is required when using the unit during rain or snow to protect internal parts from moisture damage.

Safety and Operational Guidelines

Operating power machinery demands attention to detail constantly. Ventilation is paramount because exhaust gases can be hazardous in enclosed spaces. Always ensure the engine receives adequate airflow before and during operation. Regular oil checks prevent internal damage while fuel quality impacts engine health significantly. Using the correct fuel type protects mechanisms from irreversible harm. Additionally, cold weather considerations may affect starting performance so planning ahead helps maintain functionality. Children must be kept away from running equipment as parts stay hot after shutdown. Refuelling and topping up oil must occur when the engine is stopped completely. Never operate near flammable materials or open flames during maintenance tasks involving the fuel tank.

Maximizing Performance

Following protocols extends the life of your investment significantly. Operators should learn control panel functions before attempting startup sequences. Knowing how to handle shutdown procedures prevents thermal stress on components. Storing the unit correctly during long idle periods preserves fluids. Adherence to these practices ensures peak efficiency over time without unexpected downtime. Referencing reliable guides like an Endress Diesel-Generator Manual helps clarify best practices without relying solely on memory. Ultimately, careful handling yields better results for everyone involved in the project lifecycle. Noise levels should be monitored periodically to ensure compliance with safety directives regarding acoustic emissions. Disposing of used oil respects environmental standards rather than dumping on soil. Electrical connections require qualified technicians to prevent accidental shocks or fire hazards during setup phases involving distribution panels.

M: QW-35-FL

© Copyright 2026 Manual.ly