CONTENTS (1.1):
Safety instructions ................................................................................................................. pag. 9
Preliminary checks ................................................................................................................ pag. 9
Starting the generator ......................................................................................................... pag. 10
Using the generator ............................................................................................................ pag. 10
Stopping the generator ....................................................................................................... pag. 11
Maintenance ........................................................................................................................ pag. 11
Cleaning .............................................................................................................................. pag. 11
Transportation ..................................................................................................................... pag. 11
Storage ................................................................................................................................ pag. 11
Trouble shooting .................................................................................................................. pag. 12
INTRODUCTION (2.1):
Thank you for purchasing one of our generators. We would like to draw your attention to a few points concerning this manual:
• This manual gives useful indications for the correct use and maintenance of the generator set to which it refers: it is therefore indispen-
sable to pay the fullest attention to all those paragraphs that illustrate the simplest and safest way of using the generator.
• This manual is to be considered as an integral part of the generator and must be included at the moment of purchase.
• This publication may not be reproduced, either totally or in part, without written authorization from the makers.
• All information shown hereafter is based on the data available at the moment of printing; the makers reserve the right to make modi-
fi cations to their products at any time, without warning and without incurring sanctions. You are therefore advised to check frequently
for any updates.
KEEP FOR FUTURE REFERENCE
USE OF THE GENERATOR
THIS GENERATING PLANT IS DESIGNED TO SUPPLY
THREE PHASE AND/OR SINGLE PHASE ELECTRICAL POWER.
NO OTHER APPLIANCES OTHER THAN THOSE INDICATED
SHOULD BE USED.
SAFETY INSTRUCTIONS (4.1):
ATTENTION: if the following instructions are not fully observed, injury to persons, animals and/or things could result, and the
Manufacturer does not accept responsibility for improper use.
• Do not run the generator in closed work areas: the engine produces carbon monoxide and other harmful gases detrimental to the health
of persons who work with it; make sure that the generator is well ventilated.
• Direct combustion exhaust gas outside the machine room or a reasonable distance away from the workplace and personnel. Use
piping or other extraction methods.
• The generator must only be run on a horizontal surface to guarantee optimum oil and fuel fl ow to the engine; if it is not possible to run
it on a horizontal surface, the user must provide the necessary means to anchor and align the engine to ensure the machine’s stability.
• If the generator is to be used during rain or snow, make sure that it is well and fi rmly sheltered.
• Always keep children away from the generator when in use; remember that, even after being shut off, the engine will remain at a high
temperature for about 1 hour. In the areas where the exhaust is located, the fl exible tube and the engine are subject to high temperatures
and could possibly cause severe burns if touched.
• Maintenance and servicing of the equipment must not take place while the generator is operating; always switch off the engine.
• Refuelling and topping up with oil must be done when the engine is not running; remember that the engine remains hot for about 1
hour after it is turned off.
• It is vital to be aware of the functions and controls of the generator: do not allow any unauthorized persons to use the machine.
• Improper use of the machine should be avoided: such as, using the engine to heat the surrounding atmosphere etc.
• Do not allow any unauthorized persons to use the machine; to ensure the generator cannot operate, block the system (remove the
starter key, close and lock the door of the switchboard).
• The machine does not need to be in a specially lighted area. However provide adequate lighting to comply with applicable working
norms.
• Do not remove the protection devices and do not use the machine without adequate protection (sides and casing) or the use may be
at risk.
• Should it be necessary to remove the protection devices (for maintenance and servicing), this operation should be done with the ge-
nerator switched off and only by specialized persons.
• Do not use the machine in an explosive atmosphere.
• In the case of an emergency do not use water to extinguish a fi re, use only the correct type of equipment (a powder loaded fi re extin-
guisher, etc.).
• Whenever it is necessary to work in close proximity to the machine, sound muffl er should be used (head muffs, ear plugs, etc.).
ATTENTION: Avoid any direct bodily contact with fuel, motor oil or battery acid. In case of contact with the skin wash with water
and soap and rinse thoroughly; do not use organic solvents. In case of contact with the eyes, wash with water and soap and
rinse thoroughly. In case of inhalation and swallowing, consult a medical practitioner.
PRELIMINARY CHECKS (5.1):
• Make sure these operations are carried out with the generator placed on a horizontal and stable surface.
• Oil is the most important element infl uencing the effi ciency and long life of the engine. In the use and maintenance manual are shown
details of the type of oil to use and the correct oil level for this generator.
ATTENTION: Running the engine with insuffi cient oil could cause serious damage.
• Check the fuel level: use clean fuel free of water.
ATTENTION: Fuel is highly infl ammable and explosive under certain conditions.
Refuel in a well ventilated area with the engine switched off. During refueling do not smoke and do not approach the equipment
with an open fl ame.
Do not overfi ll the tank (do not fi ll up to the cap), because vibration from the running engine could cause fuel spillage. Pay attention not
to spill fuel while fi lling the tank. Ensure that the cap is correctly screwed down after fi lling. If fuel has been spilt, ensure that the area
is completely dry before switching on the engine. Avoid any bodily contact with the fuel and do not inhale the vapour. It is important to
GB

Chat with your Endress Diesel Generator manual using AI

Get instant AI answers from your Endress Diesel Generator manual

Ask anything about the Endress Diesel Generator. Answers come from this manual, with the pages they are based on.

Diesel Generator Maintenance Schedule

Remind me when maintenance is due
Every 6 months
Inspect noise-reducing components

Check exhaust pipe, silent-blocks, air filter, mechanical tightening, fans, and sound insulation for wear to ensure compliance with noise directives.

Show in the manual (page 17)
When plates are uncovered
Top up battery with distilled water

Keep battery terminals well greased and top up elements with distilled water when the plates become uncovered.

Show in the manual (page 17)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Diesel Generator?

Yes No

Frequently Asked Questions

A

No, do not run in closed areas. Engines produce carbon monoxide. Ensure proper ventilation to avoid poisoning risks.

Is this answer helpful?

A

Use only unleaded petrol for gasoline models or diesel fuel as specified. Other fuels cause irreversible damage to the engine.

Is this answer helpful?

A

Check on a horizontal surface. Fill to ideal level shown in manual to prevent severe internal engine damage.

Is this answer helpful?

A

Warranty depends on authorized service. Tampering by unauthorized personnel voids conditions immediately.

Is this answer helpful?

A

Disconnect loads then idle for two to three minutes to cool down before switching off the engine.

Is this answer helpful?

A

Check protection switches and fuses. Verify connections and condensers are in good condition before restarting.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Robust design supports dual voltage and varied electrical configurations for different load needs.
  • Comprehensive safety protocols protect users from electrocution and exhaust fume risks significantly.
  • Accessible maintenance points streamline routine checks like oil and filter inspections easily.
VS

Disadvantages

  • Requires strict ventilation to prevent carbon monoxide poisoning in enclosed areas effectively.
  • Initial fueling and oil checks must be performed carefully before first startup sequence.
  • Electrical connections often require qualified technicians to ensure safe wiring installation properly.
  • High temperatures remain after shutdown posing burn risks near exhaust components immediately.
M: QW-35-FL

Product Specification

Type

Diesel Generator

Engine Power

5.7kW (7.64HP), 26.55in3, 3000RPM, 4-stroke, Yanmar L100

Rated Power

3kW (230V), 4.5kW (400V)

Fuel Tank Capacity

6.34gal

Display

No

Protection Class

IP23

Noise Level

105dB(A)

Weight

273.37lb

M: QW-35-FL

Product Description

Discovering Reliability with Endress Power Solutions

When you need dependable energy during sudden outages or remote work, finding the right equipment is crucial for success. The Endress Diesel-Generator stands out as a robust choice for applications requiring consistent power output regardless of environmental conditions. Whether for residential backup protection or industrial operations demanding continuous flow, this machine delivers performance where it counts most. Understanding how to operate such machinery safely and efficiently is vital for safety and equipment longevity. Proper guidance ensures users avoid common pitfalls during installation and daily use.

Key Features and Versatility

These units are designed with versatility in mind for diverse user groups. Many models allow dual voltage configurations providing greater flexibility for different electrical setups. You might find options for single phase or three phase outputs depending on specific load requirements. This adaptability makes them suitable for sites ranging from small workshops to larger construction projects. Maintenance is streamlined through accessible components like filter systems and battery chargers which simplify routine checks. Ensuring stability on horizontal surfaces guarantees optimal oil and fuel flow to the engine. If vertical operation is impossible, anchoring and leveling methods are necessary. Shelter is required when using the unit during rain or snow to protect internal parts from moisture damage.

Safety and Operational Guidelines

Operating power machinery demands attention to detail constantly. Ventilation is paramount because exhaust gases can be hazardous in enclosed spaces. Always ensure the engine receives adequate airflow before and during operation. Regular oil checks prevent internal damage while fuel quality impacts engine health significantly. Using the correct fuel type protects mechanisms from irreversible harm. Additionally, cold weather considerations may affect starting performance so planning ahead helps maintain functionality. Children must be kept away from running equipment as parts stay hot after shutdown. Refuelling and topping up oil must occur when the engine is stopped completely. Never operate near flammable materials or open flames during maintenance tasks involving the fuel tank.

Maximizing Performance

Following protocols extends the life of your investment significantly. Operators should learn control panel functions before attempting startup sequences. Knowing how to handle shutdown procedures prevents thermal stress on components. Storing the unit correctly during long idle periods preserves fluids. Adherence to these practices ensures peak efficiency over time without unexpected downtime. Referencing reliable guides like an Endress Diesel-Generator Manual helps clarify best practices without relying solely on memory. Ultimately, careful handling yields better results for everyone involved in the project lifecycle. Noise levels should be monitored periodically to ensure compliance with safety directives regarding acoustic emissions. Disposing of used oil respects environmental standards rather than dumping on soil. Electrical connections require qualified technicians to prevent accidental shocks or fire hazards during setup phases involving distribution panels.

M: QW-35-FL

© Copyright 2026 Manual.ly