Eltako FSR14-2x Manual
PDF manual · 2 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your Eltako FSR14-2x manual using AI
Get instant AI answers from your Eltako FSR14-2x manual
Ask anything about the Eltako FSR14-2x. Answers come from this manual, with the pages they are based on.
Ask a Question
Do you recommend FSR14-2x?
Yes NoFrequently Asked Questions
The device consumes a mere 0.1 watt in standby mode, promoting energy efficiency even when idle.
Is this answer helpful?
The modular design fits seamlessly onto DIN-EN 60715 TH35 rails, taking up only one module width.
Is this answer helpful?
Yes, the unit retains its switching state during power failures, ensuring consistent operation upon restoration.
Is this answer helpful?
It supports FBH motion, FTD brightness, FTK window, FRW smoke, FWS water probes, and vibration sensors.
Is this answer helpful?
Yes, only skilled electricians should install this equipment to prevent risks of fire or electric shock.
Is this answer helpful?
The housing supports environmental conditions ranging from minus 20 to 50 degrees Celsius for operation.
Is this answer helpful?
Scene control allows channels to operate in unison via a pressed button using taught-in scene buttons.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Extremely low standby consumption of just 0.1 watt
- Patented Duplex technology reduces contact wear significantly
- Retains switching state during power failures
- Modular design fits standard DIN rail easily
- Supports numerous wireless sensor types
Disadvantages
- Requires skilled electrician for safe installation
- Complex teaching-in process with multiple switches
- Limited compatibility strictly to RS485 bus systems
- No manual on back of device
- Addressing requires external tools like FAM14
Product Specification
Type
Actuator
Standard
EnOcean, RS485
Function
Switch Actuator (on/off)
Topology
Bus
Special Features
IP20
Product Description
Eltako FSR14 2x RS485 Bus Relay Overview
The Eltako FSR14-2x RS485-Bus Impulse switching relay represents a significant step forward in modular control systems. Designed specifically for professionals managing complex electrical installations, this device offers robust performance. It features two independent channels operating on impulse switching principles with an integrated relay function. Each channel supports potential-free normally open contacts capable of handling up to 16 amperes at 250 volts AC. This high capacity extends to 2000 watts when connected to incandescent or halogen lamps, ensuring compatibility with various lighting loads.
One standout feature is the patented Eltako Duplex technology. This innovation allows for zero-passage switching when handling 230 V AC voltage at 50 Hz. By connecting the neutral conductor correctly to the specific terminal, users drastically reduce wear on metal contacts, extending the lifespan of the actuators. Furthermore, the device consumes a mere 0.1 watt in standby mode, promoting energy efficiency even when idle. The modular design fits seamlessly onto DIN-EN 60715 TH35 rails, taking up only one module width of 18 millimeters while remaining 58 millimeters deep.
Connectivity is streamlined through the standard Eltako-RS485 bus system, allowing for cross wiring and centralized power management using jumpers. The unit retains its switching state during power failures, ensuring consistent operation upon restoration or defaults to an off mode. Configuration is intuitive via three rotary switches on the front panel. Electricians can easily teach-in wireless sensors and buttons to customize control logic without complex software. This includes FBH motion sensors, FTD brightness sensors, and FTK window contacts, enabling a versatile smart building environment.
Safety remains a top priority, with warnings emphasizing that only skilled electricians should install this equipment. Proper handling prevents risks of fire or electric shock during the connection phase. The housing supports environmental conditions ranging from minus 20 to 50 degrees Celsius for operation. Scene control capabilities allow multiple channels across different units to operate in unison via a single button press using scene buttons. This facilitates complex lighting scenarios without extensive wiring changes.
Technical Specifications and Usage Tips
The device includes LED indicators for teach-in confirmation and control command signaling. Users can configure behavior for water probes and smoke alarms depending on channel settings. The RV time and EW time settings allow precise control over delay durations for impulse switches. For advanced setup, the FAM14 address assignment tool works in tandem with the actuator. This integration ensures reliable communication across the RS485 network. You can also set windows to active when closed or open to trigger outputs for alarms. Water probes can signal water level to trigger alarms automatically. Smoke alarms link per channel to close contacts on detection. Vibration sensors can trigger switches manually or automatically for security. Always follow the manual for correct jumper placement to avoid device malfunction. Ensure wireless sensors are taught in the actuators correctly to execute commands. You may clear the memory fully if the device was previously taught in. This relay is a crucial component for efficient building management systems.
Search for 67,706 Manuals online
Type-in Brand or Model