Manual.ly Logo

Eltako B4T55 Manual

0.0 · 0 Ratings

PDF manual · 1 Pages

English

M: QW-35-FL
page

/ 1

Loading...
a7d8197d0809d190e4ab7f0b91fc828e53a5 page 1
GB
Bus pushbutton B4T55
30 000 290 - 1
Bus pushbutton for single mounting
80x80x15mm. For connection to
FTS14TG pushbutton gateway.
Only 0.2 watt standby loss.
B4T55 bus 4-way pushbutton in
E-design, only 16mm high.
The scope of supply comprises a mount-
ing base, an attachment frame with
snapped-on electronics, a frame R, a
rocker and a double rocker.
The double rocker permits entry of
4 evaluable signals, but the rocker
allows only 2 signals.
At the rear, a 20cm long red/black bus
line is routed externally. Red terminal to
BP, black to BN of a pushbutton gateway
FTS14TG.
Up to 30 bus switches and/or FTS61BTK
pushbutton bus couplers can be con-
nected to terminals BP and BN of an
FTS14TG pushbutton gateway. The per-
mitted maximum line length is 200m.
The RLC device enclosed with the
FTS14TG must also be connected to the
terminals BP and BN on the bus switch
or pushbutton bus coupler furthest away.
A voltage of 29V DC is supplied to the
connected B4 over a 2-wire pushbutton
bus which is also used for data transfer.
Please use only conventional bus or
telephone lines.
Confirmation telegrams from actuators
are displayed by 4 resp. 2 yellow LEDs
when the actuator IDs are entered by the
PCT14 in the ID table of the FTS14TG.
Use the sleeves in the 55mm socket box
for screw mounting.
Installation Stilt
Only skilled electricians may install
this electrical equipment otherwise
there is the risk of fire or electric
shock!
Temperature at mounting location:
-20°C up to +50°C.
Storage temperature: -25°C up to +70°C.
Relative humidity:
annual average value <75%.
for
screw
mounting
.
Installation: Screw on mounting plate.
First attach the frame and then snap on
the mounting frame with the electronics
(labelling 0 must be above). When you
fit the rocker, the 0 mark on the rear
must always be on top.
We recommend stainless-steel counter-
sunk screws 2.9x25mm, DIN 7982 C,
for screw connections. Both with rawl
plugs 5x25mm and with 55mm switch
boxes.
Rocker:
top sends 0x70
bottom sends 0x50
Double rocker:
top left sends 0x30
bottom left sends 0x10
top right sends 0x70
bottom right sends 0x50
Operating mode rotary switches of the
FTS14TG:
Pos. 2, 3, 4: Every pushbutton of the
B4T55 has the same ID.
Recommended setting for ES functions
with direction pushbutton.
Pos. 5, 6, 7: Every pushbutton of the
B4T55 has a separate ID.
Prescribed setting with ER functions.
Issue device address for B4T55:
1. Connect the first B4T55 to the BP and
BN bus terminals.
The LED on the B4T55 lights up red.
2.Turn the rotary switch on the FTS14TG
to Pos. 1.
After the FTS14TG issues the address,
its lower LED lights up green.
3.Turn the rotary switch on the FTS14TG
to Pos. 2 to 7.
The LED on the B4T55 lights up green.
4.Only then connect the second B4T55
and repeat the procedure from 2, etc.
A device address 0 (as-delivered state)
can only be issued to one B4T55.
The address is always issued in ascend-
ing order 1-30.
When a B4T55 is replaced and the
rotary switch on the FTS14TG is turned to
Pos. 1, the new B4T55 automatically re-
ceives the same device address and the
system runs as before without requiring
further teach-in.
Typical connection
* alternatively FTS14KS without
bidirectional wireless
The second terminating resistor supplied
with the FAM14 or FTS14KS must be
plugged into the last bus user Use the
The second terminating resistor supplied
with the FAM14 or FTS14KS must be
plugged into the last bus user. Use the
PCT14 PC tool to make additional actuator
setting options for conventional pushbut-
tons. An FTS14TG pushbutton gateway
can be connected decentrally to up to
30 B4T55 bus switches and FTS61BTK
pushbutton bus couplers each with 4
pushbutton inputs. A single 2-wire line
supplies the pushbutton bus coupler with
power and also transfers the pushbutton
data. The user may select any topology
for the 2-wire connection.
Clear device address of a B4T55:
1. Connect only one B4T55 to the BP
and BN bus terminals.
The LED on the B4T55 lights up
green.
2. Turn the rotary switch on the
FTS14TG to Pos. 9.
After the device is cleared, the lower
LED on the FTS14TG lights up green
and the LED on the B4T55 lights up
red.
LED display:
LEDs off: There is no power supply over
the 2-wire bus.
Red LED lights up: Power is supplied
over the 2-wire bus. The B4T55 has no
device address yet or the bus is defective.
Green LED lights up: B4T55 has a de-
vice address and is ready to operate.
Use a jumper to disable the green LED off.
Typical connection
*
a
lt
erna
ti
ve
l
y
FTS14KS
w
ith
ou
t
bidirectional wireless
The second terminating resistor supplied
with the FAM14 or FTS14KS must be
plugged into the last bus user. Use the
PCT14 PC tool to make additional actuator
setting options for conventional pushbut-
tons. An FTS14TG pushbutton gateway
can be connected decentrally to up to
30 B4T55 bus switches and FTS61BTK
pushbutton bus couplers each with 4
pushbutton inputs. A single 2-wire line
supplies the pushbutton bus coupler with
power and also transfers the pushbutton
data. The user may select any topology
for the 2-wire connection.
Eltako GmbH
D-70736 Fellbach
Technical Support English:
Michael Thünte +49 176 13582514
Marc Peter +49 173 3180368
eltako.com
20/2017 Subject to change without notice.
Must be kept for later use!

Chat with your Eltako B4T55 manual using AI

Get instant AI answers from your Eltako B4T55 manual

Ask anything about the Eltako B4T55. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend B4T55?

Yes No

Frequently Asked Questions

A

A single Taster-Gateway FTS14TG can support up to 30 Bus-Tasters like the B4T55 or Bus-Taster couplers.

Is this answer helpful?

A

Connect the first unit, set the gateway switch to position 1, wait for the green LED, then move to positions 2-7 before connecting subsequent units.

Is this answer helpful?

A

Yes, if you swap a B4T55 and rotate the gateway switch to position 1, the new unit automatically adopts the previous address.

Is this answer helpful?

A

A red light means power is present but the device lacks an address or there is a bus disturbance.

Is this answer helpful?

A

The system supplies 29V DC over the 2-wire connection to power the device and transmit data simultaneously.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Low standby power consumption of only 0.2 watts ensures energy efficiency
  • Supports both 2-signal and 4-signal inputs via interchangeable rocker covers
  • Compact 16mm height design fits perfectly into standard E-Design frames
VS

Disadvantages

  • Mandatory installation by qualified electrical personnel due to safety risks
  • Requires specific FTS14TG gateway for operation and cannot work standalone
  • Address configuration must follow strict ascending order rules during setup
M: QW-35-FL

Product Specification

Type

Sensor

Standard

Radio Bus

Function

Push Button

Topology

Star

Dimensions

3.15x3.15x0.59 in

M: QW-35-FL

Product Description

Eltako B4T55: The Versatile Bus Taster for Smart Control

The Eltako B4T55 represents a pinnacle of efficiency in modern building automation systems. Designed specifically for single mounting, this bus taster integrates seamlessly into any E-Design installation requiring precise control. With dimensions of 80x80x15mm, it offers a sleek profile that fits comfortably over standard 55mm switch boxes or onto wall surfaces using the included mounting frame and plate. This device is engineered to connect directly to Taster-Gateways like the FTS14TG, enabling robust communication across complex networks.

One of the standout features of the Eltako B4T55 is its dual-function capability via interchangeable covers. Users can install a standard rocker switch to input two distinct signals or upgrade to a double rocker configuration that handles four separate evaluable signals. This flexibility allows for diverse applications ranging from simple on-off switching to complex multi-step commands. Powering the device is an efficient 2-wire bus system that delivers 29V DC while simultaneously transmitting data, ensuring minimal energy consumption with a standby loss of only 0.2 watts.

Installation requires care and should strictly be performed by qualified electricians due to fire and shock hazards if handled incorrectly. The unit operates reliably within a temperature range of -20°C to +50°C during use. Communication is visualized through yellow LEDs that confirm actuator telegram receipt when configured correctly via the PCT14 tool. Address assignment is straightforward, allowing up to 30 devices per gateway, with automatic address retention if a unit is swapped out. Whether used for conventional switching or advanced ES functions, the B4T55 provides a reliable, compact, and highly adaptable solution for professional installations.