Manual.ly Logo

EK Water Blocks EK-Quantum Kinetic TBE D5 PWM D-RGB Manual

0.0 · 0 Ratings

PDF manual · 20 Pages

English

M: QW-35-FL
page

/ 20

Loading...
5915c1b9827c3b5f2c7e625d651a728d1943 page 1
INSTALLATION MANUAL
EK-Quantum
Kinetic TBE D5 PWM
PUMP & RESERVOIR COMBO

Chat with your EK Water Blocks EK-Quantum Kinetic TBE D5 PWM D-RGB manual using AI

Get instant AI answers from your EK Water Blocks EK-Quantum Kinetic TBE D5 PWM D-RGB manual

Ask anything about the EK Water Blocks EK-Quantum Kinetic TBE D5 PWM D-RGB. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend EK-Quantum Kinetic TBE D5 PWM D-RGB?

Yes No

Frequently Asked Questions

A

Plug the 3-pin connector to the +5V GRB header. Ensure the arrow on the connector aligns with the +5V line on the motherboard.

Is this answer helpful?

A

No, do not place the pump at the top. This restriction prevents the pump from losing prime during startup or restart cycles.

Is this answer helpful?

A

G1/4 threads must be five millimeters or shorter to avoid damage to the reservoir housing or top ports.

Is this answer helpful?

A

Run the pump for at least twenty four hours outside the system with only the PSU powered to check for leaks.

Is this answer helpful?

A

Replace the flat anticyclone with the enclosed EK-HD Tube to improve circulation and clear air bubbles.

Is this answer helpful?

A

G1/4 plugs are included for unused ports. Fittings for the actual tubes are usually sold separately.

Is this answer helpful?

A

Yes, it is recommended if air bleeding problems occur or if the pump is circulating air excessively.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • PWM G2 motor ensures efficient speed control and low noise levels.
  • TBE reservoir design offers high fluid capacity for stable cooling.
  • D-RGB lighting integration allows sync with motherboard software.
  • Includes internal tube kit for better air bleeding performance.
VS

Disadvantages

  • Pump cannot be oriented upside down relative to the chassis.
  • Fitting threads must not exceed five millimeters in length.
  • Requires twenty four hours of leak testing for safety.
  • Pump holder installation may require drilling new holes.
M: QW-35-FL

Product Specification

Connections

G1/4"

Lighting

LED (RGB)

Color

clear (transparent), black (matte)

Features

incl. mount

M: QW-35-FL

Product Description

Elevating Your PC Cooling Experience with EK Water Blocks

When customizing a high performance computer, the cooling system becomes the centerpiece of your build. The EK Water Blocks Quantum Line EK-Quantum Kinetic TBE D5 D-RGB offers a perfect blend of capacity and speed. This reservoir pump combo is designed for enthusiasts who demand silence and efficiency. It serves as the heart of your liquid cooling loop while providing a visual highlight.

Core Pump Performance

Inside the assembly lies a robust D5 PWM G2 motor. This component ensures that flow rates remain consistent even under heavy water cooling loads. The motor speed can be adjusted to match thermal requirements precisely. This modulation helps reduce noise when the system is idle. The included pump holder allows for flexible positioning within your chassis. It is built to withstand the constant vibration of operation.

Reservoir Design and Fluid Dynamics

The reservoir section utilizes a TBE design known for its volume capacity. It features a pre-installed flat anticyclone to manage internal fluid flow. If you experience air bleeding issues or excessive vortexing, you can swap to an enclosed EK-HD Tube. This modification helps clear trapped air bubbles effectively within the system. The internal tube kit is available for the top port to improve intake stability. Proper sealing gaskets ensure no leaks occur at connection points during high flow rates.

Installation and Safety Guidelines

Mounting this unit requires specific attention to orientation rules. The pump cannot be installed at the very top of the loop configuration. This restriction prevents the pump from losing prime during startup or restart cycles. The mounting kit includes screws and plastic washers for secure attachment to metal plates. You should drill holes accurately using the included sticker guide for alignment. Always ensure all threads on fittings are five millimeters or shorter to avoid damage to the plastic housing.

Lighting and Connectivity

The system features integrated D-RGB LEDs controlled by a five volt header. You must connect the three pin connector to the correct motherboard pinout. The positive voltage line must align with the arrow on the connector. Incorrect wiring can damage your motherboard or the light strip. Unused ports must be blocked with G1/4 plugs provided in the box.

Testing Protocols and Longevity

A thorough leak test is recommended before powering on the full system. Run the pump for at least twenty four hours without other components. This allows the loop to fill while you monitor for any fluid loss. Once the loop is confirmed dry and sealed, integrate it into your build. Trust this unit to maintain stability over long periods of gaming and editing tasks.

M: QW-35-FL

© Copyright 2026 Manual.ly