c37dd09c5733e9c36c2a468c7c636950785f page 2
This product is intended for installation by expert users only.
Please consult with a qualified technician for installation. Improper
installation may result in damage to your equipment. EK Water
Blocks assumes no liability whatsoever, expressed or implied,
for the use of these products, nor their installation. The following
instructions are subject to change without notice. Please visit
our web site at www.ekwb.com for updates. Before installation,
please read important notice, disclosure, and warranty conditions
printed on the back of the box.
Before you start using this product please follow these basic guidelines:
Please, read the manual carefully before you begin with the
installation process!
EK-Loop Angled Bracket - 140/140mm is compatible with
EK-QuantumX Loophole Distroplate.

Chat with your EK Water Blocks EK-Loop Angled Bracket manual using AI

Get instant AI answers from your EK Water Blocks EK-Loop Angled Bracket manual

Ask anything about the EK Water Blocks EK-Loop Angled Bracket. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend EK-Loop Angled Bracket?

Yes No

Frequently Asked Questions

A

This product is intended for installation by expert users only. Please consult with a qualified technician for installation. Improper installation may result in damage to your equipment.

Is this answer helpful?

A

The EK-Loop Angled Bracket - 120/140mm is compatible with the EK-QuantumX Loophole Distroplate for effective integration within your cooling system.

Is this answer helpful?

A

Yes, it can be mounted onto a 120 mm format radiator using M4 x 5 mm Phillips head radiator mounting screws without needing additional nuts.

Is this answer helpful?

A

You can drill four 4.5mm holes in the most suitable place on the wall of your computer chassis if existing mounting spots are unavailable.

Is this answer helpful?

A

Acetal standoffs are crucial. Without them placed correctly, you risk the possibility of scratching your FLT product especially when using EK-Torque HTC-16 Fittings.

Is this answer helpful?

A

Make sure the acetal standoffs are placed correctly before attaching fittings. We recommend using EK-Fittings because of their compatibility and reduced worry.

Is this answer helpful?

A

EK Water Blocks assumes no liability whatsoever, expressed or implied, for the use of these products nor their installation.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Compatible with EK QuantumX Loophole Distroplate for seamless integration within custom loops.
  • Adjustable slot holes allow fifty millimeter positioning on sides for flexible mounting options.
  • Includes necessary M4 screws and hardware for direct case or radiator installation securely.
  • Supports 120 mm and 140 mm fan mounts adapting to various chassis designs easily.
  • Acetal standoffs protect reservoir surfaces from scratches during fitting attachment processes.
VS

Disadvantages

  • Intended for expert users only requiring consultation with qualified technician for safety.
  • Limited installation possibilities on small radiators compared to larger surface area alternatives.
  • Risk of scratching FLT products if acetal standoffs are placed incorrectly by builder.
  • Drilling holes required for some installations which may void warranty on computer cases.
  • Manufacturer assumes no liability for damages resulting from improper installation attempts.
M: QW-35-FL

Product Specification

Type

Mount

Color

black (matte)

Special Features

tool included

M: QW-35-FL

Product Description

Elevating Custom Cooling Performance With Structural Brackets

Building a high performance custom loop system requires more than just premium pumps and reservoirs. You need reliable structural components that ensure absolute stability and precise flow routing throughout your entire rig. The EK Water Blocks EK-Loop Angled Bracket serves this critical purpose within advanced chassis configurations used by enthusiasts seeking top tier thermal management solutions. Designed primarily for expert builders, this component effectively bridges the gap between complex reservoir placement options and strict internal case constraint limitations found in modern PC builds. Many hobbyists look at the EK Water Blocks EK-Loop Angled Bracket Manual details during their initial research phase before committing to specific part purchases for their next project build cycle completion.

Compatibility And System Integration Planning

When planning your water cooling layout, knowing exactly which hardware fits your specific components is absolutely crucial for success within tight enclosures. This particular angled bracket works specifically with the EK QuantumX Loophole Distroplate ecosystem for seamless integration capabilities. It broadly supports both one hundred twenty millimeter and one hundred forty millimeter fan mounts depending on your available spatial requirements inside the chassis volume. Most users opt to mount the one hundred forty millimeter format FLT reservoir directly onto this sturdy bracket design immediately after securing the base plate properly. This specific setup allows for extremely secure attachment within the enclosed case environment utilizing standard metric M4 screws provided conveniently in the original shipping package for all buyers.

Installation Flexibility Options Available

Installation procedures offer multiple distinct pathways based entirely on your specific case design preferences and available real estate space constraints. You can mount the unit directly into the computer case enclosure whenever sufficient space for a one hundred forty millimeter fan area exists nearby the intended location. Alternatively, drilling four designated holes measuring 4.5mm diameter provides significant flexibility for custom wall placement scenarios away from standard mounting points always allowed. Radiator mounting capabilities are also fully supported using dedicated M4 Phillips head screws designed for heat exchanger security against movement vibrations. For larger radiator sizes such as three hundred sixty millimeter models, you might utilize middle hole placements for added operational stability under heavy system load conditions constantly.

Assembly Considerations And Maintenance Notes

Proper assembly ensures long term longevity and prevents potential coolant leaks occurring later during active usage cycles over many years. The base features specialized slot holes allowing adjustable positioning approximately fifty millimeters on either side relative to the central axis line measured carefully. Side pieces connect securely via pre drilled threaded holes eliminating the frequent need for extra washers in certain specific assembly scenarios encountered by technicians. However, plastic acetal standoffs must be positioned correctly before attaching metal fittings to prevent scratching sensitive surfaces on fluid transfer lines permanently during future maintenance windows. Always refer to manufacturer guidelines regarding specific torque limits when tightening fasteners manually to ensure safety standards are met consistently every single time you work on your rig safely.

Note: Liability coverage does not extend to damage caused by improper installation techniques performed incorrectly by untrained personnel without guidance. Professional consultation is strongly recommended for novice builders encountering complex setups for the first time ever in their history. Always check current documentation on official websites before purchasing new hardware kits online today. Ensure all included packaging contents match your chosen case specifications completely prior to beginning any physical modifications to your personal computer system interior walls permanently. Safety remains the paramount concern when working with live electrical equipment and pressurized fluid containers inside enclosed computing towers daily. Maintain a clean clear workspace and utilize appropriate precision tools for maximum safety assurance during every step of the modification process involved here now.