fc5ed43b1cd8d7d21cd71257e8dd0c90f1b3 page 15
CLAGE
EN
21
3. How to use
• Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use
abrasive or chlorine-based cleaning agents or solvents.
• For a good water supply, the outlet fittings (e.g. jet regulators and shower heads)
should be unscrewed and cleaned at regular intervals. Every three years, the electri-
cal and plumbing components should be inspected by an authorised professional in
order to ensure proper functioning and operational safety at all times.
Cleaning and maintenance
This instantaneous water heater features an automatic air bubble protection to prevent
it from inadvertently running dry. Nevertheless, the appliance must be vented before
using it for the first time. Each time the appliance is emptied (e.g. after work on the
plumbing system, if there is a risk of frost or following repair work), the appliance must
be re-vented before it is used again.
1. Disconnect the instantaneous water heater from the mains (e.g. via deactivating the
fuses).
2. Unscrew the jet regulator on the outlet fitting and open the cold water tap valve to
rinse out the water pipe and avoid contaminating the appliance or the jet regulator.
3. Open and close the hot water tap until no more air emerges from the pipe and all
air has been eliminated from the water heater.
4. Only then should you re-connect the power supply again (e.g. via activating the
fuses) to the instantaneous water heater and screw the jet regulator back in.
5. The appliance activates the heater after approx. 10seconds of continuous water
flow.
Venting after maintenance work

Chat with your Clage DCX Next manual using AI

Get instant AI answers from your Clage DCX Next manual

Ask anything about the Clage DCX Next. Answers come from this manual, with the pages they are based on.

DCX Next Maintenance Schedule

Remind me when maintenance is due
Every 3 years
Inspect electrical and plumbing components

Have an authorised professional inspect electrical and plumbing components to ensure proper function and operational safety.

Show in the manual (page 21)
Regularly
Clean outlet fittings

Unscrew and clean outlet fittings such as jet regulators and shower heads regularly to maintain good water supply.

Show in the manual (page 21)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: gpt-5.6-terra

Ask a Question

0/1000

Do you recommend DCX Next?

Yes No

Frequently Asked Questions

A

It is an electronically controlled instant water heater for supplying hot water to one or more tap outlets. It heats water as it flows through the unit, automatically starting when a hot-water tap opens and stopping when the tap closes.

Is this answer helpful?

A

The central sensor key cycles through five preset outlet temperatures: 35 C, 38 C, 42 C, 48 C, and 55 C. Colored LEDs indicate the active selection. These settings are intended for common uses such as hand washing, showering, bathing, kitchen work, and cleaning.

Is this answer helpful?

A

A flashing temperature LED can indicate that the heater has reached its power limit. This can occur when incoming water is cold or the flow rate is too high. Reducing the hot-water flow at the tap can allow the unit to reach the selected temperature.

Is this answer helpful?

A

The DCX 13 Next can be configured for 11 or 13.5 kW. The DCX Next can be configured for 18, 21, 24, or 27 kW at 400 V. An authorized professional must set the maximum power according to the electrical installation.

Is this answer helpful?

A

Yes. It must be vented before first operation and after the appliance has been drained, such as following plumbing work, repairs, or frost protection measures. Disconnect power, flush the water lines, remove air through the hot-water tap, then restore power.

Is this answer helpful?

A

Wipe plastic surfaces and fittings with a damp cloth only. Clean aerators and shower heads regularly to protect water flow. The filter strainer may need cleaning or replacement if flow weakens. Electrical and plumbing components should be inspected by an authorized professional every three years.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Electronically controlled heating helps maintain a selected temperature despite changing inlet conditions and water pressure.
  • Five preset temperatures from 35 C to 55 C provide quick choices for hand washing, showers, kitchen use, and cleaning.
  • Automatic switch-on and switch-off delivers hot water on demand without a storage tank.
  • Multiple Power System settings let authorized installers adapt output from 11 to 27 kW, depending on the model.
  • LED status indicators show selected temperature, heating activity, flow status, output limitation, and detected faults.
VS

Disadvantages

  • Temperature may not reach the selected level when inlet water is cold and flow demand exceeds available heater output.
  • Installation requires a permanent three-phase electrical connection and must be completed by an authorized specialist.
  • The unit must be installed in a frost-free location and remain accessible for maintenance.
  • Only five fixed temperature settings are available, rather than fully variable degree-by-degree selection.
  • Filters, aerators, and shower heads need periodic cleaning to maintain strong hot-water flow.
M: gpt-5.6-terra

Product Specification

Energy efficiency class

A (A+ to F)

Rated power

18-27 kW (400 V)

Rated current

26-39 A

Temperature control

95-131°F, 5 levels

Inlet temperature

max. 86°F

Flow rate

max. 2.11 gal/min

Design

closed (pressure-resistant)

Mounting type

wall-mounted

Connection

1/2 in

Special features

electronic control, bare-wire heating system, air detection system

Protection rating

IP25

Noise level

15 dB(A)

Dimensions

9.41 x 18.43 x 3.78 in (W x H x D)

Weight

9.26 lb

M: gpt-5.6-terra

Product Description

Clage DCX Next Electric Tankless Water Heater - Read, Download & Print Free

The Clage DCX Next Electric Tankless Water Heater is a compact, electronically controlled solution for dependable hot water at one or more outlets. Designed for decentralized installation, it heats water only when a hot-water tap is opened and switches off automatically when the tap is closed. This on-demand approach avoids storing heated water in a tank and helps match energy use to everyday demand.

Precise temperature control for daily routines

A central sensor key lets users cycle through five practical temperature settings: 35 C for hand washing, 38 C for showering, 42 C for bathing, 48 C for kitchen tasks, and 55 C for cleaning. Five colored LEDs show the selected setting at a glance. The electronic control continuously considers inlet temperature and flow rate to maintain the chosen outlet temperature as accurately as possible, including during water-pressure fluctuations.

When incoming water is especially cold or demand is high, the heater may reach its available output limit. In this situation, the selected temperature LED flashes to indicate that reducing the flow at the tap can help achieve a hotter outlet temperature. This clear visual feedback supports more predictable use in changing seasonal conditions.

Flexible power and installation options

The DCX Next range includes the DCX 13 Next, adjustable between 11 and 13.5 kW, and the DCX Next, configurable between 18, 21, 24, and 27 kW at 400 V. This Multiple Power System allows an authorized installer to select an output suitable for the local electrical installation. Both models use a bare-wire IES heating system, have G 1/2 inch water connections, and are rated IP25.

The unit is intended for wall mounting in frost-free rooms and can support pressure-resistant or pressureless connections. Optional mounting accessories can help accommodate difficult pipe layouts, surface-mounted installations, or uneven wall conditions. Because the electrical connection and power setting require professional work, correct planning is essential before installation.

Everyday care and useful status information

For convenient monitoring, holding the sensor key activates an information mode. LED signals show whether water is flowing, heating is active, the power limit is reached, or an error has been detected. Regular care is straightforward: wipe exterior surfaces with a damp cloth and clean shower heads, aerators, and outlet fittings periodically. A professional inspection of electrical and plumbing components is recommended every three years.

Notes

  • Vent the heater fully before first use and after draining, repairs, or plumbing work.
  • Use only hot water at the tap when checking the selected outlet temperature.
  • The product carries energy efficiency class A and is made with reusable materials and components.