df80468c3e690984a4a1a0992ae152ac4c28 page 20
Step 3
Secure the grounding lug to the chassis grounding pad with two M4 screws (see Callouts 1 and 3 in the previous figure),
and tighten the screws to 11 to 15 in-lb (1.24 to 1.69 N·m) of torque.
Step 4
After you install the chassis, prepare the other end of the grounding wire and connect it to an appropriate grounding point
in your site to ensure an adequate earth ground for the switch.
Starting the Switch
You start the switch by connecting it to its dedicated power source. If you need n+1 redundancy, you must
connect each of the power supplies to one or two power sources. If you need n+n redundancy, you must
connect each power supply in a switch to a different power source.
Before You Begin
•
The switch must be installed and secured to a rack or cabinet.
•
The switch must be adequately grounded.
•
The rack must be close enough to the dedicated power source so that you can connect the switch to the
power source by using a designated power cables.
•
You have the designated power cables for the power supplies that you are connecting to the dedicated
power sources.
Depending on the outlet receptacle on your AC power distribution unit, you might need
an optional jumper power cord to connect the switch to your outlet receptacle.
Note
•
The switch is not connected to the network (this includes any management or interface connections).
•
The fan and power supply modules are fully secured in their chassis slots.
All of the fan slots must be filled with fan modules and the power supply slots must be filled with the
same types of power supplies (do not mix AC and DC power supplies).
Step 1
For each AC power supply, do the following:
a) Using the recommended AC power cable for your country or region, connect one end to the AC power supply.
b) Connect the other end of the power cable to the AC power source.
Step 2
For each HVAC/HVDC power supply, connect it to a power source as follows:
a) Using the recommended high voltage power cable for your country or region, connect the Anderson Power Saf-D-Grid
connector on the power cable to the power receptacle on the power supply. Make sure that the connector clicks when
fully pushed into the receptacle.
b) Connect the other end of the power cable to a power source.
•
When connecting to an HVAC power source, insert the C14 or LS-25 plug in a receptacle for the HVAC power
source.
Cisco Nexus 93108TC-FX ACI Mode Hardware Installation Guide
22
Installing the Switch Chassis
Starting the Switch

Chat with your Cisco Nexus 93108TC-FX manual using AI

Get instant AI answers from your Cisco Nexus 93108TC-FX manual

Ask anything about the Cisco Nexus 93108TC-FX. Answers come from this manual, with the pages they are based on.

Nexus 93108TC-FX Maintenance Schedule

As needed
Clean transceiver connectors

Clean connectors regularly depending on the environment and if exposed to dust or touched. Use wet or dry cleaning techniques.

Show in the manual (page 32)
Routine
Inspect fiber optics for damage

Inspect routinely for dust and damage. If suspected, clean and inspect fiber ends under a microscope.

Show in the manual (page 32)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Nexus 93108TC-FX?

Yes No

Frequently Asked Questions

A

It is best suited for dense data center leaf deployments that need many 10G copper access ports and a smaller number of high-speed uplinks. It fits structured rack environments where airflow and redundancy matter.

Is this answer helpful?

A

The switch provides 48 RJ-45 10GBASE-T access ports and 6 QSFP28 uplink ports. That combination supports high-density server connectivity while leaving room for fast fabric aggregation.

Is this answer helpful?

A

No. The chassis must use the same power supply type throughout. AC, DC, and HVAC/HVDC power supplies should not be mixed in one switch. Matching wattage and airflow direction is also required.

Is this answer helpful?

A

Confirm that the switch is properly mounted, grounded, and cabled. Also verify that all fan and power modules are installed, share the same airflow direction, and are connected to suitable power sources.

Is this answer helpful?

A

Yes, the fan modules and power supplies are field-replaceable. The replacement must match the installed airflow direction, and the process should be done carefully to preserve cooling and uptime.

Is this answer helpful?

A

Use a compatible 19-inch rack or cabinet with enough front and rear clearance for airflow and cabling. The rack should be stable, grounded, and positioned close enough to power sources for safe connection.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • 48 RJ-45 ports support dense 10G copper server connectivity in a compact 1RU chassis.
  • Six QSFP28 uplinks offer strong scaling for 40G or 100G fabric connections.
  • Redundant, field-replaceable fans and power supplies improve serviceability and uptime.
  • Airflow options help the switch fit hot-aisle and cold-aisle data center layouts.
VS

Disadvantages

  • All fan and power modules must use the same airflow direction, or the switch may overheat.
  • Installation requires careful grounding, rack clearance, and power planning.
  • AC, DC, and HVAC/HVDC power supplies cannot be mixed in the same chassis.
  • Compatible cables, transceivers, and adapters must be checked before deployment.
M: OA-GPT-54-NAN

Product Specification

Function

Switch, SAN Switch

Type

Standalone, Rackmount (via mounting brackets)

Network ports

48x RJ-45, 6x QSFP28

Speeds

48x RJ-45 (100/1000/10GBase-T), 6x QSFP28 (10G/40G/100Gb/s)

PoE

N/A

Backplane

2.16Tb/s, 850Mp/s, 40MB packet buffer, 512k MAC addresses

Officially supported standards

802.1AX, 802.1D, 802.1Q, 802.1AE, 802.1p, 802.3ab, 802.3ae, IGMP

Configuration

Web interface, Console, serial (RJ-45, USB-A 2.0, rear), Network (SFP+, RJ-45, dedicated, 10/100/1000Base-T, rear)

Cooling

active, 4x fans (1.57in, 1 hot-plug each)

Dimensions (WxHxD)

17.28x1.73x22.48in, 1U

Weight

17.42 lb

Color

silver

Special features

Metal housing, removable mounting brackets, firmware updates possible, redundant power supply (redundant power input), 2x hot-plug capable power supply

Manufacturer warranty

one year

Note

For this device, "link aggregation" was officially specified with the obsolete standard IEEE802.3ad. Since 2008, the function is no longer managed by the IEEE "Working Group 3" (IEEE 802.3, CSMA/CD - Ethernet), but by "Working Group 1" (IEEE 802.1, High Level Interface - Internetworking) and technically defined unchanged via IEEE 802.1AX.

M: OA-GPT-54-NAN

Product Description

Cisco Nexus 9300-FX MACsec Rackmount 10G Managed Switch, 48x RJ-45, 6x QSFP28

The Cisco Nexus 9300-FX MACsec Rackmount 10G Managed Switch, 48x RJ-45, 6x QSFP28 Manual points to a platform built for dense data center leaf deployments, where reliable access switching and fast uplinks need to work together. In a compact 1RU chassis, the switch combines forty-eight 10GBASE-T RJ-45 ports for server-facing connections with six QSFP28 uplinks for high-speed aggregation.

What stands out is its balance of flexibility and discipline. The design supports hot-aisle and cold-aisle planning, interchangeable fan modules, and redundant power supplies, so teams can adapt the hardware to the rack layout without sacrificing serviceability. That makes it a practical choice for structured environments where uptime, airflow control, and cable management matter as much as raw port density.

This switch family is aimed at installations that need clear operating rules. The chassis must be grounded, power sources should be planned carefully, and all fans and power modules must share the same airflow direction. Those requirements may seem strict, but they help maintain stable cooling and reduce the chance of shutdowns under load. Optional console and management connections also make first-time setup and ongoing troubleshooting much easier.

For teams planning a network refresh, the appeal is straightforward: many copper access links without giving up uplink bandwidth. The 48 RJ-45 ports simplify server connectivity, while the six QSFP28 ports leave room for 40G or 100G uplinks depending on the fabric design. In practice, that combination supports scalable leaf-spine topologies and helps keep the rack footprint efficient.

The MACsec-oriented positioning adds another layer of value for organizations that care about link protection and operational control. Paired with Cisco-style fabric workflows, the switch fits neatly into a modern data center strategy where security, performance, and maintainability all need to move together.

Notes

  • Match airflow direction before powering on.
  • Use supported transceivers, cables, and power options.
  • Keep the rack grounded and leave enough clearance for cabling and service access.
  • Verify LEDs, fans, and power supplies after startup.